Spectral Transmittance of Intraocular Lenses under Natural and Artificial Illumination
Purpose To compare the spectral transmission of different intraocular lenses (IOLs) with either ultraviolet (UV) or blue-light filters, and to analyze the performance of these filters with artificial light sources as well as sunlight. Design Experimental study. Methods The spectral transmission curve of 10 IOLs was measured using a PerkinElmer Lambda 800 UV/VIS spectrometer (Waltham, MA). Different filtering simulations were performed using the D65 standard illuminant as daylight and standard incandescent lamp and fluorescent bulb illuminants. Main Outcomes Measures Spectral transmittance of the IOLs. Results All the IOLs studied provide good UVC (200–280 nm) and UVB (280–315 nm) protection…