0000000000775690
AUTHOR
Ahmed Othman
showing 5 related works from this author
Fixed lingual orthodontic retainer with bilateral missing lateral incisors produced in PEEK material using CAD/CAM technology
2021
Background The aim of this investigation is to evaluate the feasibility of digital workflow for lingual fixed retainer based on digital intraoral scan and appliance production from Polyetheretherketone (PEEK) material for clinical consideration. Material and methods Fully virtual lingual retainer with bilateral missing lateral incisors was designed using inlab software (Dentsply Sirona, Pennsylvania, USA). The designed retainer was produced in PEEK material and clinically adhered to lingual surfaces of the lower front teeth. Results Lingual retainer was successfully fabricated by full digital workflow and produced from PEEK material for clinical usage. Conclusions Although full digital work…
Comparison of the shear bond strength of 3D printed temporary bridges materials, on different types of resin cements and surface treatment
2019
Background Thus, purpose of this study was to compare the shear bond strength of the resin cement and the resin modified glass ionomer cement on 3D printed temporary material for crowns and bridges in combination with different surface treatment modalities. Material and methods Test specimens VarseoSmile Temp material (Bego, Bremen, Germany) (n=64) in the form of rectangular blocks (n=32) and cylindrical test specimens (n=32) were printed using the Varseo S 3D printer (Bego, Bremen, Germany). The specimens were divided into 4 groups, with 8 specimens of each kind. Two groups (n=16 pairs) were blasted with Perlablast® Micro [PM] 50µm (Bego, Bremen, Germany) and two groups (n=16 pairs) were b…
Shear force comparative evaluation for surface treated and non- treated 3D interim printed materials with different types of glass-ionomer cements
2020
Background The purpose of this investigation was to compare shear force of different glass-ionomer cements on 3D printed interim material in combination with and without surface pretreatment. Material and Methods 120 rectangular specimens made of printable provisional material (Bego, Bremen, Germany) were used. After post-processing the specimens were blasted with aluminum oxide 110µm (Bego, Bremen, Germany). Extra 120 non-surface treated specimens were used as an experimental negative test group. All 240 specimens were divided randomly into 6 groups. All were cemented with a compressive load of 20 N using universal testing machine Z010 (Zwick/Roell, Ulm, Germany) to ensure a comparable cem…
Mechanical evaluation for three-dimensional printed orthodontic springs with different heights-in vitro study
2021
Background The orthodontic spring materials in use have a significant influence on the applied forces. The prerequisite to identify the in vitro< force deflection of the CAD/CAM fabricated springs is considered mandatory to identify the material characteristics. The purpose of the present investigation was to evaluate the mechanical load on 3D printed springs using different coil heights. Material and Methods The springs were digitally designed with different coil heights using Autodesk Netfabb CAD software (San Rafael, CA, USA). Test specimens were manufactured using 3D printable experimental flexible material (Code: BM2008, GC, Tokyo, Japan). The specimens were divided according to the co…
Fracture strength test of digitally produced ceramic-filled and unfilled dental resin restorations via 3d printing : an in vitro study
2023
Purpose of this study was to investigate the mechanical efficiency of 3D-printed permanent and provisional implant cemented fixed bridges produced via CAD/CAM technology using an interim and a permanent ceramic filled hybrid material. Two groups with tw