0000000000788131

AUTHOR

L. Lauer

showing 4 related works from this author

Quantification of Regional Intrapulmonary Oxygen Partial Pressure Evolution during Apnea by 3He MRI

1999

We present a new method to determine in vivo the temporal evolution of intrapulmonary oxygen concentrations by functional lung imaging with hyperpolarized (3)Helium ((3)He-->). Single-breath, single-bolus visualization of (3)He--> administered to the airspaces is used to analyze nuclear spin relaxation caused by the local oxygen partial pressure p(O(2))(t). We model the dynamics of hyperpolarization in the lung by rate equations. Based hereupon, a double acquisition technique is presented to separate depolarization by RF pulses and oxygen induced relaxation. It permits the determination of p(O(2)) with a high accuracy of up to 3% with simultaneous flip angle calibration using no additional …

AdultMaleNuclear and High Energy PhysicsApneaSwinePartial PressureBiophysicsAnalytical chemistrychemistry.chemical_elementHyperpolarized Helium 3HeliumBiochemistryOxygenNuclear magnetic resonanceIsotopesFlip angleAnimalsHumansHyperpolarization (physics)LungPhantoms ImagingRelaxation (NMR)DepolarizationPartial pressureCondensed Matter PhysicsMagnetic Resonance ImagingOxygenchemistryLimiting oxygen concentrationJournal of Magnetic Resonance
researchProduct

Aligned microcontact printing of biomolecules on microelectronic device surfaces

2001

Microcontact printing (/spl mu/CP) of extracellular matrix proteins is a fascinating approach to control cell positioning and outgrowth, which is essential in the development of applications ranging from cellular biosensors to tissue engineering. Microelectronic devices can be used to detect the activity from a large number of recording sites over the long term. However, signals from cells can only be recorded at small sensitive spots. Here, the authors present an innovative setup to perform aligned /spl mu/CP of extracellular matrix proteins on microelectronic devices in order to guide the growth of electrogenic cells specifically to these sensitive spots. The authors' system is based on t…

extra cellular matrixMaterials scienceTransistors ElectronicSurface PropertiesSiliconesBiomedical EngineeringmicroelectrodesNanotechnologyHippocampuslaw.inventionRats Sprague-DawleyTissue engineeringlawfield effect transistorsAnimalsMicroelectronicsDimethylpolysiloxanesCells CulturedNeuronschemistry.chemical_classificationbusiness.industryBiomoleculeOptical tableReproducibility of ResultsalignmentEquipment Designmicrocontact printing (mu CP)JExtracellular MatrixRatsMicroelectrodeextracellular recordingchemistry3D-BioMEMSMicrocontact printingmicroelectronic devicesField-effect transistorneuronal networksNeural Networks ComputerbusinessMicroelectrodesBiosensorIEEE Transactions on Biomedical Engineering
researchProduct

Analysis of intrapulmonary O2concentration by MR imaging of inhaled hyperpolarized helium-3

1999

Inhalation of hyperpolarized 3He allows magnetic resonance imaging (MRI) of ventilated airspaces.3He hyperpolarization decays more rapidly when interacting with paramagnetic O2. We describe a method for in vivo determination of intrapulmonary O2 concentrations ([O2]) based on MRI analysis of the fate of measured amounts of inhaled hyperpolarized3He in imaged regions of the lung. Anesthetized pigs underwent controlled normoventilation in a 1.5-T MRI unit. The inspired O2 fraction was varied to achieve different end-tidal [O2] fractions ([Formula: see text]). With the use of a specifically designed applicator,3He (100 ml, 35–45% polarized) was administered at a predefined time within single …

SwinePhysiologychemistry.chemical_elementHyperpolarized Helium 3HeliumOxygenIsotopesPhysiology (medical)Administration InhalationTidal VolumemedicineAnimalsHyperpolarization (physics)Respiratory systemLungTidal volumeLungmedicine.diagnostic_testInhalationbusiness.industryRespirationOsmolar ConcentrationMagnetic resonance imagingMagnetic Resonance ImagingOxygenmedicine.anatomical_structurechemistryFeasibility StudiesNuclear medicinebusinessJournal of Applied Physiology
researchProduct

The rapid atmospheric monitoring system of the Pierre Auger Observatory

2012

The Pierre Auger Observatory is a facility built to detect air showers produced by cosmic rays above 1017 eV. During clear nights with a low illuminated moon fraction, the UV fluorescence light produced by air showers is recorded by optical telescopes at the Observatory. To correct the observations for variations in atmospheric conditions, atmospheric monitoring is performed at regular intervals ranging from several minutes (for cloud identification) to several hours (for aerosol conditions) to several days (for vertical profiles of temperature, pressure, and humidity). In 2009, the monitoring program was upgraded to allow for additional targeted measurements of atmospheric conditions shor…

[PHYS.ASTR.HE]Physics [physics]/Astrophysics [astro-ph]/High Energy Astrophysical Phenomena [astro-ph.HE]AstronomyFOS: Physical sciencesCosmic rayReal-time monitoring01 natural sciencesLarge detector systems for particle and astroparticle physics Real-time monitoring Control and monitor systems onlineOptical telescopeObservatory0103 physical sciencesSHOWERSLarge detector systems for particle and astroparticle physics; Real-time monitoring; Control and monitor systems onlineFLUORESCENCE010303 astronomy & astrophysicsInstrumentationInstrumentation and Methods for Astrophysics (astro-ph.IM)DETECTORMathematical PhysicsRemote sensingEvent reconstructionPierre Auger ObservatoryHigh Energy Astrophysical Phenomena (astro-ph.HE)010308 nuclear & particles physicsLarge detector systems for particle and astroparticle physicsControl and monitor systems online[SDU.ASTR.HE]Sciences of the Universe [physics]/Astrophysics [astro-ph]/High Energy Astrophysical Phenomena [astro-ph.HE]FísicaENERGY-SPECTRUMMonitoring programControl and monitor systems online; Large detector systems for particle and astroparticle physics; Real-time monitoringAerosolATMOSFERA (MONITORAMENTO)Air showerExperimental High Energy PhysicsFísica nuclearAstrophysics - Instrumentation and Methods for AstrophysicsAstrophysics - High Energy Astrophysical Phenomena
researchProduct