0000000000794044

AUTHOR

Estevam A. Bonfante

showing 3 related works from this author

Bone regeneration at extraction sockets filled with leukocyte-platelet-rich fibrin: An experimental pre-clinical study

2022

We aimed to histomorphometrically evaluate the effects of Leucocyte-Platelet-Rich Fibrin (L-PRF), with and without the combination of a bone grafting material, for alveolar ridge preservation using an in vivo canine model. Seven dogs (Female Beagles, ~18-month-old) were acquired for the study. L-PRF was prepared from each individual animal by drawing venous blood and spinning them through a centrifuge at 408 RCF-clot (IntrasSpin, Intra-Lock, Boca Raton, FL). L-PRF membranes were obtained from XPression fabrication kit (Biohorizons Implant Systems, Inc., AL, USA). A split mouth approach was adopted with the first molar mesial and distal socket defects treated in an interpolated fashion of th…

Bone Regenerationmouth neoplasmsMolaroral diagnosisDogsOtorhinolaryngologyhealth service coveragePlatelet-Rich FibrinTooth ExtractionAlveolar ProcessLeukocytesAnimalsFemaleSurgeryTooth SocketGeneral DentistryUNESCO:CIENCIAS MÉDICASMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Surface characterization and in vivo evaluation of laser sintered and machined implants followed by resorbable-blasting media process: A study in she…

2015

Background This study aimed to compare the histomorphometric and histological bone response to laser-sintered implants followed by resorbable-blasting media (RBM) process relative to standard machined/RBM surface treated implants. Material and Methods Six male sheep (n=6) received 2 Ti-6Al-4V implants (1 per surface) in each side of the mandible for 6 weeks in vivo. The histomorphometric parameters bone-implant contact (BIC) and bone area fraction occupancy (BAFO) were evaluated. Results Optical interferometry revealed higher Sa and Sq values for the laser-sintered/RBM surface in relation to standard/RBM implants. No significant differences in BIC were observed between the two groups (p>0.2…

MaleMaterials scienceSurface PropertiesDentistryOdontología02 engineering and technologyBone ResponseOsseointegrationlaw.invention03 medical and health sciences0302 clinical medicinelawIn vivoOsseointegrationAnimalsGeneral DentistryDental ImplantsSheepbusiness.industryLasersResearchDental Implantation Endosseous030206 dentistryBone area021001 nanoscience & nanotechnologyBiocompatible materialLaser:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludSelective laser sinteringOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryOral Surgery0210 nano-technologybusinessRock blastingMedicina oral, patologia oral y cirugia bucal
researchProduct

Drilling dimension effects in early stages of osseointegration and implant stability in a canine model

2015

Background: This study histologically evaluated two implant designs: a classic thread design versus another specifically designed for healing chamber formation placed with two drilling protocols. Material and Methods: Forty dental implants (4.1 mm diameter) with two different macrogeometries were inserted in the tibia of 10 Beagle dogs, and maximum insertion torque was recorded. Drilling techniques were: until 3.75 mm (regular-group); and until 4.0 mm diameter (overdrilling-group) for both implant designs. At 2 and 4 weeks, samples were retrieved and processed for histomorphometric analysis. For torque and BIC (bone-to-implant contact) and BAFO (bone area fraction occupied), a general-linea…

MaleInsertion torqueMaterials scienceDentistryOdontologíaOdontologiOsseointegrationinitial stabilityDogsOsseointegrationAnimalsbiomechanicalTibiaGeneral DentistryDental ImplantsHistomorphometrybusiness.industryResearchDental Implantation EndosseousImplant designosseointegrationDrillingInitial stability:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludin vivoOtorhinolaryngologyDentistryModels AnimalUNESCO::CIENCIAS MÉDICASSurgeryImplantOral Surgerybusinessinsertion torqueCanine modelMedicina Oral Patología Oral y Cirugia Bucal
researchProduct