Physicochemical stability of human insulin 1 I.U./mL infusion solution in 50 mL polypropylene syringes
Abstract Objectives The objective of this study was to investigate the physicochemical stability of human insulin 1 I.U./mL injection solutions (Insuman® Rapid) diluted with 0.9% NaCl solution in 50 mL disposable three-piece polypropylene syringes and stored refrigerated or at room temperature. Methods 1 I.U./mL test solutions were prepared with Insuman® Rapid and 0.9% sodium chloride infusion solution in 50 mL Original-Perfusor® syringes and BD® Perfusion syringes. Test solutions were stored for 90 days at 2–8 °C/dark or 48 h at 20–25 °C/diffuse room light in order to determine chemical stability. Additional test solutions were stored 28 days at 2–8 °C/dark followed by 24 h at 20–25 °C/dif…