0000000000845450

AUTHOR

Aki Ilander

showing 11 related works from this author

The determination of antimony and arsenic concentrations in fly ash by hydride generation inductively coupled plasma optical emission spectrometry

2011

Abstract Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) was used in the determination of As and Sb concentrations in fly ash samples. The effect of sample pre-treatment reagents and measurement parameters used for hydride generation was evaluated. Due to memory effects observed, the appropriate read delay time was adjusted to 60 s resulting in RSDs 0.6% and 2.3% for As and Sb, respectively. The most suitable volumes of pre-reduction reagents for 10 mL of sample were 4 mL of KI/ascorbic acid (5%) and 6 mL of HCl (conc.). The determination of Sb was significantly interfered by HF, but the interference could be eliminated by adding 2 mL of saturated bo…

AntimonyChromatographySpectrophotometry AtomicAnalytical chemistrychemistry.chemical_elementHydrochloric acidAscorbic acidCoal AshBiochemistryCarbonArsenicAnalytical ChemistryBoric acidchemistry.chemical_compoundBoric AcidsAntimonychemistryFly ashInductively coupled plasma atomic emission spectroscopyEnvironmental ChemistryParticulate MatterInductively coupled plasmata116SpectroscopyArsenicAnalytica Chimica Acta
researchProduct

An ultrasound-assisted digestion method for the determination of toxic element concentrations in ash samples by inductively coupled plasma optical em…

2007

Abstract A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of toxic element concentrations (arsenic, barium, cobalt, copper, lead, nickel, strontium, vanadium and zinc) in ash samples was developed. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg(II) 280.270 nm/Mg(I) 285.213 nm line intensity ratios. The highest line intensity ratios were observed when a nebulizer gas flow of 0.6 L min−1, auxiliary gas flow of 0.2 L min−1 and plasma power of 1400 W were used for radially viewed plasma. The analysis of SRM 1633b showed that the ultrasound-ass…

ChromatographyMicrowave ovenAnalytical chemistrychemistry.chemical_elementBariumZincBiochemistryAnalytical Chemistrychemistry.chemical_compoundDigestion (alchemy)chemistryEnvironmental ChemistryAqua regiaInductively coupled plasmaMicrowave digestionSpectroscopyArsenicAnalytica chimica acta
researchProduct

The determination of trace element concentrations in fly ash samples using ultrasound-assisted digestion followed with inductively coupled plasma opt…

2009

Abstract A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of trace element (chromium, copper, lead, nickel, vanadium and zinc) concentrations in fly ash samples was developed. All the measurements were performed in robust plasma conditions. Ultrasound-assisted digestion procedures using digestion solutions of aqua regia and hydrofluoric acid (HF) resulted in recovery rates of over 80% for all the analyte elements. Ultrasound-assisted two-step digestion with digestion solutions of 6 mL of HNO3 (Step 1) and 3 mL of HNO3 + 3 mL of HF (Step 2) resulted in recovery rates of over 92% for all the ana…

AnalyteChromatographyAcoustics and UltrasonicsOrganic ChemistryAnalytical chemistrychemistry.chemical_elementZincInorganic Chemistrychemistry.chemical_compoundChromiumDigestion (alchemy)chemistryFly ashChemical Engineering (miscellaneous)Environmental ChemistryAqua regiaRadiology Nuclear Medicine and imagingInductively coupled plasmaMicrowave digestionUltrasonics sonochemistry
researchProduct

Optimization of operating conditions of axially and radially viewed plasmas for the determination of trace element concentrations from ultrasound-ass…

2006

Abstract The method of ultrasound-assisted extraction followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of trace element concentrations (arsenic, copper, lead, antimony, and zinc) in shooting range areas was optimized. Optimization was achieved not only on the basis of the analysis of appropriate standard reference materials but also on that of 31 synthetic mixtures of matrix and analyte elements (aluminum, antimony, arsenic, calcium, copper, lead, iron, manganese, silicon, and zinc), in five concentrations. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg II 280.270 nm/Mg I 285.213 …

Analytical chemistrychemistry.chemical_elementZincPlasmaBiochemistryCopperAnalytical ChemistryMatrix (chemical analysis)chemistryAntimonyInductively coupled plasma atomic emission spectroscopyEnvironmental ChemistryInductively coupled plasmaSpectroscopyArsenicAnalytica Chimica Acta
researchProduct

Determination of mineral and trace element concentrations in pine needles by ICP-OES: evaluation of different sample pre-treatment methods

2008

In the present study, the determination of mineral and trace elements (Al, B, Ca, Cu, Fe, K, Mg, Mn, Na, P and Zn) from pine needles using three sample pre-treatment methods followed by inductively coupled plasma optical emission spectrometry, was examined. Sample pre-treatment methods tested were microwave digestion, ultrasound-assisted digestion and dry ashing. The new ultrasound-assisted digestion method was optimised by the analysis of the standard reference material (SRM) 1575a (pine needles) sample. The speed of dry ashing method was significantly increased by ultrasound dissolution after ashing. All the ICP-OES measurements were performed in robust plasma conditions which were tested…

ChemistryHealth Toxicology and MutagenesisPublic Health Environmental and Occupational HealthAnalytical chemistryTrace elementSoil SciencePollutionAnalytical ChemistryDigestion (alchemy)AshingInductively coupled plasma atomic emission spectroscopyEnvironmental ChemistryMicrowave digestionInductively coupled plasmaWaste Management and DisposalDissolutionMicrowaveWater Science and TechnologyInternational Journal of Environmental Analytical Chemistry
researchProduct

Weathering of gasification and grate bottom ash in anaerobic conditions

2009

Abstract The effect of anaerobic conditions on weathering of gasification and grate bottom ash were studied in laboratory lysimeters. The two parallel lysimeters containing the same ash were run in anaerobic conditions for 322 days, after which one was aerated for 132 days. The lysimeters were watered throughout the study and the quality of leachates and changes in the binding of elements into ash were observed. The results show that organic carbon content and initial moisture of ashes are the key parameters affecting the weathering of ashes. In the grate ash the biodegradation of organic carbon produced enough CO 2 to regulate pH. In contrast the dry gasification ash, containing little org…

Environmental EngineeringChemistryHealth Toxicology and MutagenesisCarbonationEnvironmental engineeringWeatheringCarbon DioxideHydrogen-Ion ConcentrationPollutionAbsorptionchemistry.chemical_compoundCarbonatationBottom ashEnvironmental chemistryCarbon dioxideEnvironmental ChemistryAnaerobiosisLeachateLeaching (agriculture)AerationWaste Management and DisposalJournal of Hazardous Materials
researchProduct

Control of matrix interferences by multiple linear regression models in the determination of arsenic and lead concentrations in fly ashes by inductiv…

2010

A multiple linear regression technique was used to evaluate and correct the matrix interferences in the determination of As and Pb concentrations in fly ashes by inductively coupled plasma optical emission spectrometry. The direct determination of As and Pb in SRM 1633b by ICP-OES failed to obtain the certified concentrations, except in a couple of cases. However, it proved possible to use the multiple linear regression (MLR) technique to correct the determined concentrations to a satisfactory level. This method of correction is based on the multiple regression line obtained from the analysis of 19 synthetic mixtures of matrix and analyte elements (Al, As, Ca, Fe, Pb, and Si) at five concen…

AnalyteChromatographyChemistryAnalytical chemistrychemistry.chemical_elementPlasmaAnalytical ChemistryMatrix (chemical analysis)Fly ashStandard additionLinear regressionInductively coupled plasmaSpectroscopyArsenicJournal of Analytical Atomic Spectrometry
researchProduct

Development of ultrasound-assisted digestion methods for the determination of toxic element concentrations in ash samples by ICP-OES

2011

The present thesis introduces several ultrasound-assisted digestion methods developed for the determination of toxic element concentrations in ash samples by inductively coupled plasma optical emission spectrometry (ICP-OES). Ultrasound-assisted digestion is a quite new technique used for sample pre-treatment purposes, especially in difficult sample matrixes. Elements determined are As, Ba, Co, Cr, Cu, Ni, Pb, Sb, Sr, V, and Zn. Most of the elements determined exist at a trace or ultra trace level in ashes and most are potential risks in the environment or human body even at low concentrations. Most of the selected elements can be determined directly by ICP-OES, but for the determination of…

maatalouskemikaalitinductively coupled plasma optical emission spectrometryspektrometripolymorphinterferenceashultraäänisupramolecular synthontorjunta-aineetmyrkyllisyysaskaultraljudsupramolecular chemistrystructural chemistryhydride generationsolvatespektrometriaagrochemicaltuhkacocrystalgiftighettoxic elementultrasound-assisted digestionX-ray crystallography
researchProduct

The determination of antimony and arsenic concentrations in fly ash by hydride generation inductively coupled plasma optical emission spectrometry (H…

2011

Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) was used in the determination of As and Sb concentrations in fly ash samples. The effect of sample pre-treatment reagents and measurement parameters used for hydride generation was evaluated. Due to memory effects observed, the appropriate read delay time was adjusted to 60 s resulting in RSDs 0.6% and 2.3% for As and Sb, respectively. The most suitable volumes of pre-reduction reagents for 10 mL of sample were 4 mL of KI/ascorbic acid (5%) and 6 mL of HCl (conc.). The determination of Sb was significantly interfered by HF, but the interference could be eliminated by adding 2 mL of saturated boric acid …

fly ashhydride generationantimonyantimoniarsenicICP-OESlentotuhkahydridin muodostusarseeni
researchProduct

An ultrasound-assisted digestion method for the determination of toxic element concentrations in ash samples by inductively coupled plasma optical em…

2007

method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of toxic element concentrations (arsenic, barium, cobalt, copper, lead, nickel, strontium, vanadium and zinc) in ash samples was developed. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg(II) 280.270 nm/Mg(I) 285.213 nm line intensity ratios. The highest line intensity ratios were observed when a nebulizer gas flow of 0.6 L minˉ¹, auxiliary gas flow of 0.2 L minˉ¹ and plasma power of 1400 W were used for radially viewed plasma. The analysis of SRM 1633b showed that the ultrasound-assisted metho…

mikroaaltomicrowavetuhkaemission spectrometryultrasoundashultraäänimyrkylliset alkuaineettoxic element
researchProduct

Control of matrix interferences by multiple linear regression models in the determination of arsenic and lead concentrations in fly ashes by inductiv…

2010

A multiple linear regression technique was used to evaluate and correct the matrix interferences in the determination of As and Pb concentrations in fly ashes by inductively coupled plasma optical emission spectrometry. The direct determination of As and Pb in SRM 1633b by ICP-OES failed to obtain the certified concentrations, except in a couple of cases. However, it proved possible to use the multiple linear regression (MLR) technique to correct the determined concentrations to a satisfactory level. This method of correction is based on the multiple regression line obtained from the analysis of 19 synthetic mixtures of matrix and analyte elements (Al, As, Ca, Fe, Pb, and Si) at five concen…

fly ashtuhkamääritysICP-OESlyijyarseenidetermination of As and Pb
researchProduct