0000000000849266

AUTHOR

Ascensión Vicente

0000-0002-7257-5124

showing 2 related works from this author

Effect of saliva contamination on bracket failure with a self-etching primer: A prospective controlled clinical trial

2010

Introduction The aim of this study was to evaluate in vivo the effect of saliva contamination at different stages of the bonding procedure on the bond failure rate and the adhesive remaining on teeth after debonding brackets bonded with a hydrophilic self-etching primer (Transbond Plus self-etching primer [TSEP], 3M Unitek, Monrovia, Calif). Methods This was a prospective controlled clinical trial. The sample consisted of 46 patients with similar treatment plans and mechanotherapies. Stainless steel brackets (n = 531) were bonded with TSEP. The patients were divided into 2 groups: contamination with saliva before TSEP application and contamination with saliva after TSEP application. In both…

Curing Lights DentalCuspidSalivaOrthodontic BracketsSurface PropertiesDentistryOrthodonticsDental bondingDental Debondingstomatognathic systemIncisorOrthodontic WiresHumansMedicineProspective StudiesSaliva contaminationDental EnamelSalivaDental Debondingbusiness.industryBracketDental BondingStainless SteelResin CementsIncisorClinical trialstomatognathic diseasesSelf etchmedicine.anatomical_structureEquipment FailurebusinessDental AlloysFollow-Up StudiesAmerican Journal of Orthodontics and Dentofacial Orthopedics
researchProduct

Effect of water contamination on the shear bond strength of five orthodontic adhesives

2010

Objectives: To evaluate the shear bond strength and site of failure of brackets bonded to dry and wet enamel. Study design: 50 teeth were divided into ten groups of 5 teeth each (10 surfaces). In half the groups enamel was kept dry before bonding, and in the other half distilled water was applied to wet the surface after etching. The following groups were established: 1)Acid/Transbond-XT (dry/wet) XT; 2) Transbond Plus Self Etching Primer (TSEP)/Transbond-XT paste (dry/wet); 3) Concise (dry), Transbond MIP/Concise (wet), 4) FujiOrtho-LC (dry/ wet); 5) SmartBond (dry/wet). Brackets were bonded to both buccal and lingual surfaces. Specimens were stored in distilled water (24 hours at 37ºC) an…

Materials scienceDental materialsWater contaminationMaterials dentalsCementDental CementsIn Vitro TechniquesCimentOrthodontic Adhesivesstomatognathic systemHumansComposite materialGeneral DentistryUniversal testing machineContaminació de l'aiguaAdhesius dentalsEnamel paintBond strengthDental BondingWaterHumidity:CIENCIAS MÉDICAS [UNESCO]Shear bondOtorhinolaryngologyDistilled waterWater pollutionvisual_artUNESCO::CIENCIAS MÉDICASvisual_art.visual_art_mediumSurgeryAdhesiveDental adhesives
researchProduct