0000000000875580

AUTHOR

A Papi

showing 4 related works from this author

Innate immunity but not NLRP3 inflammasome activation correlates with severity of stable COPD.

2014

Background In models of COPD, environmental stressors induce innate immune responses, inflammasome activation and inflammation. However, the interaction between these responses and their role in driving pulmonary inflammation in stable COPD is unknown. Objectives To investigate the activation of innate immunity and inflammasome pathways in the bronchial mucosa and bronchoalveolar lavage (BAL) of patients with stable COPD of different severity and control healthy smokers and non-smokers. Methods Innate immune mediators (interleukin (IL)-6, IL-7, IL-10, IL-27, IL-37, thymic stromal lymphopoietin (TSLP), interferon γ and their receptors, STAT1 and pSTAT1) and inflammasome components (NLRP3, NA…

EXPRESSIONMaleINTERLEUKIN-6InflammasomesCOPD PathologyChronic Obstructive Pulmonary DiseaseRespiratory SystemImmunity NLRP3 COPDBronchiReceptors Cell SurfaceRespiratory MucosaPULMONARYInterferon-gammaPulmonary Disease Chronic ObstructiveMARKERSThymic Stromal LymphopoietinSPUTUMNLR Family Pyrin Domain-Containing 3 ProteinCytokine Receptor gp130Humans1506HMGB1 ProteinAdaptor Proteins Signal TransducingAgedScience & TechnologyRECEPTORInterleukinsSmoking1103 Clinical SciencesMiddle AgedInterleukin-1 Receptor-Like 1 ProteinImmunity InnateInnate Immunityrespiratory tract diseasesANTIINFLAMMATORY CYTOKINESTAT1 Transcription FactorCase-Control StudiesT-CELLSASTHMACytokinesFemaleCOPD Pathology Innate ImmunityCarrier ProteinsLife Sciences & BiomedicineBronchoalveolar Lavage FluidSMOKERSThorax
researchProduct

Th17-related cytokine expression is increased in the bronchial mucosa of stable COPD patients

2009

Background: There is an increased number of activated Tl lymphocytes in the bronchial mucosa of stable COPD patients but are absent studies on Th17 cells and their effector cytokines.Objectives: To investigate the expression of retinoic orphan receptor(ROR)C2, interleukin(IL)-17A,IL-17F,IL-21,IL-22 and IL-23 in bronchial biopsies from patients with stable COPD of different severity(stage 2 to 4)compared with age-matched control subject(smokers with normal lung function and lifelong non-smokers).Methods: The expression of RORC2,IL-17A,IL-17F,IL-21,IL-22 and IL-23 was measured in the bronchial mucosa using immunohistochemistry and/or real time quantitative polymerase chain reaction. Results: …

Settore BIO/16 - Anatomia UmanaLYMPHOCYTE COPD TH-17CYTOKINES
researchProduct

The beam and detector of the NA62 experiment at CERN

2017

NA62 is a fixed-target experiment at the CERN SPS dedicated to measurements of rare kaon decays. Such measurements, like the branching fraction of the $K^{+} \rightarrow \pi^{+} \nu \bar\nu$ decay, have the potential to bring significant insights into new physics processes when comparison is made with precise theoretical predictions. For this purpose, innovative techniques have been developed, in particular, in the domain of low-mass tracking devices. Detector construction spanned several years from 2009 to 2014. The collaboration started detector commissioning in 2014 and will collect data until the end of 2018. The beam line and detector components are described together with their early …

Particle physicsPhysics - Instrumentation and DetectorsPhysics::Instrumentation and DetectorsFOS: Physical scienceslarge detector systems for particle and astroparticle physicsCalorimeters; Cherenkov detectors; Large detector systems for particle and astroparticle physics; Particle tracking detectors; Instrumentation; Mathematical PhysicsNA62 experimentTracking (particle physics)7. Clean energy01 natural sciencesParticle detectorHigh Energy Physics - ExperimentSettore FIS/04 - Fisica Nucleare e SubnucleareNONuclear physicsmathematical physicsHigh Energy Physics - Experiment (hep-ex)Calorimeters0103 physical sciencesparticle tracking detectorsDetectors and Experimental Techniques010306 general physicsParticle Physicsphysics.ins-detCalorimeters; Cherenkov detectors; large detector systems for particle and astroparticle physics; particle tracking detectors; instrumentation; mathematical physicsPhysicsinstrumentationCalorimeterLarge Hadron Collider010308 nuclear & particles physicsBranching fractionhep-exDetectorCherenkov detectorsInstrumentation and Detectors (physics.ins-det)Particle tracking detectorBeamlineLarge detector systems for particle and astroparticle physicHigh Energy Physics::ExperimentBeam (structure)Particle Physics - ExperimentCherenkov detector
researchProduct

The beam and detector for the NA48 neutral kaon CP violation experiment at CERN

2007

The beam and detector, used for the NA48 experiment, devoted to the measurement of Re (ε{lunate}′ / ε{lunate}), and for the NA48/1 experiment on rare KS and neutral hyperon decays, are described. © 2007 Elsevier B.V. All rights reserved.

Nuclear and High Energy PhysicsParticle physicsacceleratoriNA62 experiment01 natural sciencesLIQUID-KRYPTON CALORIMETERDECAYSNOfasci di particelleKaon beamsNuclear physicsDRIFT CHAMBER ELECTRONICSCERNViolazione di CP0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Kaon decaysdetector; CP violation; Kaon decays010306 general physicsInstrumentation07.05.Fb; 13.20.Eb; 29.40.Vj; 29.27.EgPhysicsCalorimeterLarge Hadron ColliderdetectorCRYSTAL010308 nuclear & particles physicsLIQUID-KRYPTON CALORIMETER; DRIFT CHAMBER ELECTRONICS; PROTON TAGGING DETECTOR; PC FARM; TRIGGER; SYSTEM; READOUT; DECAYS; PERFORMANCE; CRYSTALDetectorPC FARMHyperonNA48 experimentDetectorsMagnetic spectrometerPERFORMANCErivelatoriREADOUTkaon decayCalorimeterTriggerCP violationfasci di particelle; acceleratori; CERN; Violazione di CP; rivelatori; kaon decayCP violationHigh Energy Physics::ExperimentParticle Physics - ExperimentPROTON TAGGING DETECTORSYSTEMBeam (structure)
researchProduct