Applications of confocal laser scanning microscopy to dental bonding.

1998

The introduction of confocal laser scanning microscopy (CLSM) has provided a valuable new technique for the visualization of bonding structures such as a hybrid layer in dentin (Watson, 1989, 1991), In the case of seven commercially-available dentin bonding systems, it could be demonstrated that the CLSM renders considerably more detailed information than the SEM because of its nondestructive nature and because of the possibility of a distinction between components of bonding agents. With most of the bonding systems, measurements of the thickness of the hybrid layer could be carried out when the primer component was labeled with rhodamine B. It was found that this thickness is significantl…

0301 basic medicineMaterials scienceTime FactorsAnalytical chemistryDental bondingIn Vitro TechniquesComposite Resinslaw.inventionRhodamine03 medical and health scienceschemistry.chemical_compound0302 clinical medicinestomatognathic systemAcid Etching DentalConfocal microscopylawMicroscopyDentinmedicineRhodamine BHumansCeramicComposite materialDental EnamelDental LeakageMicroscopy ConfocalEnamel paintfungiDental Bonding030206 dentistryGeneral MedicineMolar030104 developmental biologymedicine.anatomical_structurechemistryMicroscopy FluorescenceInlaysvisual_artDentin-Bonding AgentsDentinvisual_art.visual_art_mediumAdvances in dental research
researchProduct

Effect of cavity preparation instruments (oscillating or rotating) on the composite-dentin interface in primary teeth.

2003

Abstract Objectives: To evaluate the effect of preparation of instruments on the interfacial integrity between cavity wall and composite restoration. Methods: Two class II slot preparations were done in 10 primary teeth either with SonicSys® or with a conventional bur. The cavities were filled using an adhesive system. One layer of a flowable composite and one layer of a condensable composite were applied. The specimens were analyzed by confocal laser scanning microscopy. Results: In the SonicSys® group the mean thickness of the hybrid layer was 6.12 (0.60) μm; in the control group it was 6.04 (0.63) μm. The difference was not statistically significant. Two fractures were observed in one to…

Materials scienceComposite numberAnalytical chemistryComposite ResinsDental High-Speed EquipmentStatistics NonparametricDentinmedicineFlowable CompositeHumansGeneral Materials ScienceUltrasonicsComposite materialTooth DeciduousDental Restoration PermanentGeneral DentistryDental LeakageMicroscopy ConfocalEnamel paintDental BondingAdhesionBevelResin CementsDentin Permeabilitymedicine.anatomical_structureMechanics of Materialsvisual_artDentin-Bonding Agentsvisual_art.visual_art_mediumDental Cavity PreparationLayer (electronics)Cavity wallDental materials : official publication of the Academy of Dental Materials