Improved method for cannula fixation for long-term intracerebral brain infusion
Abstract Background Implanted osmotic minipumps are commonly used for long-term, brain-targeted delivery of a wide range of experimental agents by being connected to a catheter and a cannula. During the stereotactical surgery procedure, the cannula has to be placed correctly in the x-y directions and also with respect to the injection point in the z-direction (deepness). However, the flat fixation base of available cannula holders doesn’t allow an easy, secure fixation onto the curve-shaped skull. New method We have developed a modified method for a better fixation of the cannula holder by using an easy-to-produce, skull-shaped silicone spacer as fixation adapter. Results We describe the ap…