Emergent and delayed hybrid external fixation management of tibial pilon fractures: A multicentric retrospective analysis of 80 patients
Objective: To report our experience with the hybrid external fixator in emergency. Methods: We assessed 80 cases of pilon fracture treated with the external fixator during the period of January 2009 and December 2016:55 men (69%) and 30 women (33%) with a mean age of 40 years (range between 16 and 70). About 45 occurred as isolated trauma, 35 instead were politrauma. Each patient underwent standard radiographic examination and a CT examination. There were 28 open fractures (35%), (Gustilo type 1, 2 and 3) while closed fractures showed soft tissue involvement of various grade (2-3 Tscherne classification). In all cases, the external fixation, sometimes associated with other reduction and syn…