0000000000927378
AUTHOR
Athanassios Bissas
Repeatability and sensitivity of passive mechanical stiffness measurements in the triceps surae muscle‐tendon complex
Measurements of muscle-tendon unit passive mechanical properties are often used to illustrate acute and chronic responses to a training stimulus. The purpose of this study was to quantify the inter-session repeatability of triceps surae passive stiffness measurements in athletic and non-athletic populations, with the view to discussing its usefulness both as a muscle-tendon profiling tool and a control measure for studies with multiple data collection sessions. The study also aimed to observe the effects of quiet standing on passive stiffness parameters. Twenty-nine men (10 cyclists, nine triathletes, 10 controls) visited the laboratory on three separate occasions, where passive stiffness t…
Muscle‐tendon morphology and function following long‐term exposure to repeated and strenuous mechanical loading
We mapped structural and functional characteristics of muscle‐tendon units in a population exposed to very long‐term routine overloading. Twenty‐eight military academy cadets (age: 21.00 ± 1.1 yrs; height: 176.1 ± 4.8 cm; mass: 73.8 ± 7.0 kg) exposed for over 24 months to repetitive overloading were profiled via ultrasonography with a senior subgroup of them (n = 11; age = 21.4 ± 1.0 yrs; height = 176.5 ± 4.8 cm; mass = 71.4 ± 6.6 kg) also tested while walking and marching on a treadmill. A group of eleven ethnicity‐ and aged‐matched civilians (age = 21.6 ± 0.7 yrs; height = 176.8 ± 4.3 cm; mass = 74.6 ± 5.6 kg) was also profiled and tested. Cadets and civilians exhibited similar morphology…
Mechanical and neural function of triceps surae in elite racewalking
Racewalking is a unique event combining mechanical elements of walking with speeds associated with running. It is currently unclear how racewalking technique impacts upon lower limb muscle-tendon function, despite the relevance of this to muscle economy and overall performance. The present study examined triceps surae neuromechanics in 11 internationally competitive racewalkers (age 25±11 years) walking and running on a treadmill at speeds between 4.5 - 13.8 km/h whilst triceps surae fascicle lengths, electromyography and kinematic data were recorded. Cumulative muscle activity required to traverse a unit distance (CMAPD) was calculated for each muscle. Medial gastrocnemius (MG) and soleus …
Muscle‐tendon morphology and function following long‐term exposure to repeated and strenuous mechanical loading
We mapped structural and functional characteristics of muscle‐tendon units in a population exposed to very long‐term routine overloading. Twenty‐eight military academy cadets (age = 21.00 ± 1.1 years; height = 176.1 ± 4.8 cm; mass = 73.8 ± 7.0 kg) exposed for over 24 months to repetitive overloading were profiled via ultrasonography with a senior subgroup of them (n = 11; age = 21.4 ± 1.0 years; height = 176.5 ± 4.8 cm; mass = 71.4 ± 6.6 kg) also tested while walking and marching on a treadmill. A group of eleven ethnicity‐ and age‐matched civilians (age = 21.6 ± 0.7 years; height = 176.8 ± 4.3 cm; mass = 74.6 ± 5.6 kg) was also profiled and tested. Cadets and civilians exhibited similar mo…