0000000000936397

AUTHOR

Mar Baixauli-lópez

showing 2 related works from this author

Prospective study of monolithic zirconia crowns: clinical behavior and survival rate at a 5-year follow-up

2020

Purpose To evaluate the clinical behavior and survival of full coverage monolithic zirconia crowns on posterior teeth over a 5-year follow-up. Methods Fifty patients were recruited and underwent restoration with a Lava Plus monolithic zirconia crown (Lava™ Frame Zirconia, 3M Espe, Germany) on premolars or molars. Patients were monitored over a 5-year follow-up (2014-19), recording any biological and/or mechanical complications; these data were used to estimate the crowns' success rate. Periodontal clinical parameters were recorded (pocket probing depth (PPD), plaque index (PLI), bleeding on probing (BOP), and gingival recession (GR)). Wear to the zirconia crowns and antagonist teeth were al…

Molarmedicine.medical_treatment0206 medical engineeringBleeding on probingDentistry02 engineering and technologyCrown (dentistry)03 medical and health sciences0302 clinical medicinestomatognathic systemmedicineHumansDentistry (miscellaneous)Dental Restoration FailureProspective StudiesSurvival rateGingival recessionDental structureCrownsEnamel paintbusiness.industry030206 dentistry020601 biomedical engineeringSurvival Ratestomatognathic diseasesvisual_artvisual_art.visual_art_mediumPosterior teethZirconiumOral Surgerymedicine.symptombusinessFollow-Up StudiesJournal of Prosthodontic Research
researchProduct

In vitro comparison of the efficacy of two fractured implant-prosthesis screw extraction methods: Conventional versus mechanical.

2019

Abstract Statement of problem Implant-supported prostheses may be subject to esthetic, biological, or mechanical complications. Protocols for dealing with these mechanical problems are sparse. Purpose The purpose of this in vitro study was to compare the efficacy of a mechanical system for extracting fractured implant-prosthesis screws with the conventional method. Material and methods A total of 60 screws were divided into 2 groups according to their morphology (flat screws with a smooth shaft and threaded apical area and screws with a completely threaded body) and subjected to fatiguing and static load testing until fracture. The specimens were assigned to 3 operators with varying levels …

musculoskeletal diseasesDental ImplantsUltrasound deviceMaterials scienceImplant prosthesisBone Screws030206 dentistryThread (computing)Esthetics Dentalmusculoskeletal systemequipment and suppliescomputer.software_genreExtractor03 medical and health sciencesLoad testingsurgical procedures operative0302 clinical medicineCoronal planeExtraction methodsOral SurgerycomputerFracture typeBiomedical engineeringThe Journal of prosthetic dentistry
researchProduct