0000000000986459
AUTHOR
Astrid Schwabe
Physicochemical compatibility of mixtures of dornase alfa and tobramycin containing nebulizer solutions
Patients suffering from cystic fibrosis (CF) often need to inhale multiple doses of different nebulizable drugs per day. Patients attempt to shorten the time consuming administration procedure by mixing drug solutions/suspensions for simultaneous inhalation. The objective of this experimental study was to determine whether mixtures of the nebulizer solution dornase alfa (Pulmozyme) with tobramycin nebulizer solutions (TOBI and GERNEBCIN 80 mg) are physico-chemically compatible. Drug combinations were prepared by mixing the content of one respule Pulmozyme with either one respule TOBI or one ampoule GERNEBCIN 80 mg. Test solutions were stored at room temperature and exposed to light. Dornase…
Inhalation solutions: which one are allowed to be mixed? Physico-chemical compatibility of drug solutions in nebulizers.
AbstractTherapy of chronic respiratory diseases often involves inhalation therapy with nebulizers. Patients often attempt to shorten the time consuming administration procedure by mixing drug solutions/suspensions for simultaneous inhalation. This article considers the issue of physico-chemical compatibility of admixtures of drug solutions/suspensions in nebulizers.A search of databases, prescribing information and primary literature was conducted to locate literature concerning the physico-chemical compatibility of inhalation solutions/suspensions. This was supplemented by telephone interviews.Admixtures of albuterol with ipratropium and/or cromolyn, of albuterol and budesonide, or tobramy…