SHIPTRAP—a capture and storage facility for heavy radionuclides at GSI
Abstract SHIPTRAP will be an ion-trap facility for heavy radionuclides delivered from SHIP. Ion traps are a perfect instrument for precision measurements since the ions can be cooled to an extremely small phase space and can be stored for a very long time. In addition one can achieve very high purity by removing contaminant ions. SHIPTRAP will extend the possibilities of measurements in traps to transuranium nuclides and provide cooled and isobarically pure ion bunches.
Status of the SHIPTRAP Project: A Capture and Storage Facility for Heavy Radionuclides from SHIP
The ion trap facility SHIPTRAP is being set up to deliver very clean and cool beams of singly-charged recoil ions produced at the SHIP velocity filter at GSI Darmstadt. SHIPTRAP consists of a gas cell for stopping and thermalizing high-energy recoil ions from SHIP, an rf ion guide for extraction of the ions from the gas cell, a linear rf trap for accumulation and bunching of the ions, and a Penning trap for isobaric purification. The progress in testing the rf ion guide is reported. A transmission of about 93(5)% was achieved.