0000000001008752

AUTHOR

R. Budnik

showing 14 related works from this author

Intrinsic backgrounds from Rn and Kr in the XENON100 experiment

2018

In this paper, we describe the XENON100 data analyses used to assess the target-intrinsic background sources radon ([InlineMediaObject not available: see fulltext.]), thoron ([InlineMediaObject not available: see fulltext.]) and krypton ([InlineMediaObject not available: see fulltext.]). We detail the event selections of high-energy alpha particles and decay-specific delayed coincidences. We derive distributions of the individual radionuclides inside the detector and quantify their abundances during the main three science runs of the experiment over a period of ∼4years, from January 2010 to January 2014. We compare our results to external measurements of radon emanation and krypton concentr…

data analysis methodPhysics - Instrumentation and DetectorsPhysics and Astronomy (miscellaneous)WIMPFOS: Physical scienceschemistry.chemical_elementlcsh:AstrophysicsRadonSciences de l'ingénieur01 natural sciencesIonNuclear physicsradon: nuclideXENONlcsh:QB460-4660103 physical scienceslcsh:Nuclear and particle physics. Atomic energy. Radioactivity[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsInstrumentation and Methods for Astrophysics (astro-ph.IM)[ PHYS.PHYS.PHYS-INS-DET ] Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Engineering (miscellaneous)nuclidebackground: radioactivitybackground: suppressionkryptonPhysicsRadionuclidePhysique010308 nuclear & particles physicsKryptonInstrumentation and Detectors (physics.ins-det)Alpha particleAstronomieDark Matter direct search experimentrespiratory tract diseasesRadon DaughtersBackgroundchemistrylcsh:QC770-798TPCAstrophysics - Instrumentation and Methods for Astrophysics
researchProduct

First Axion Results from the XENON100 Experiment

2014

We present the first results of searches for axions and axion-like-particles with the XENON100 experiment. The axion-electron coupling constant, $g_{Ae}$, has been tested by exploiting the axio-electric effect in liquid xenon. A profile likelihood analysis of 224.6 live days $\times$ 34 kg exposure has shown no evidence for a signal. By rejecting $g_{Ae}$, larger than $7.7 \times 10^{-12}$ (90% CL) in the solar axion search, we set the best limit to date on this coupling. In the frame of the DFSZ and KSVZ models, we exclude QCD axions heavier than 0.3 eV/c$^2$ and 80 eV/c$^2$, respectively. For axion-like-particles, under the assumption that they constitute the whole abundance of dark matte…

Nuclear and High Energy PhysicsParticle physicsAstrophysics and AstronomyCosmology and Nongalactic Astrophysics (astro-ph.CO)astro-ph.GADark matterchemistry.chemical_elementFOS: Physical sciencesAstrophysics01 natural sciencesCosmologydark matterXenonHigh Energy Physics - Phenomenology (hep-ph)Assioni0103 physical sciences010306 general physicsAxionLiquid XenonCouplingCoupling constantQuantum chromodynamicsPhysics010308 nuclear & particles physicshep-phAstrophysics - Astrophysics of GalaxiesGalaxyHigh Energy Physics - Phenomenologychemistry[PHYS.HPHE]Physics [physics]/High Energy Physics - Phenomenology [hep-ph]Astrophysics of Galaxies (astro-ph.GA)astro-ph.COAstrophysics - Cosmology and Nongalactic Astrophysics
researchProduct

Results from a calibration of XENON100 using a source of dissolved radon-220

2017

A Rn 220 source is deployed on the XENON100 dark matter detector in order to address the challenges in calibration of tonne-scale liquid noble element detectors. We show that the Pb 212 beta emission can be used for low-energy electronic recoil calibration in searches for dark matter. The isotope spreads throughout the entire active region of the detector, and its activity naturally decays below background level within a week after the source is closed. We find no increase in the activity of the troublesome Rn 222 background after calibration. Alpha emitters are also distributed throughout the detector and facilitate calibration of its response to Rn 222 . Using the delayed coincidence of R…

Physics - Instrumentation and DetectorsPhysics::Instrumentation and DetectorsDark matterFOS: Physical scienceschemistry.chemical_elementRadon01 natural sciencesCoincidenceNuclear physicsRecoilOpticsXenonXENON DARK MATTER WIMPS CALIBRATION RADON0103 physical sciencesCalibration[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsPhysics010308 nuclear & particles physicsbusiness.industryDetectorAstrophysics::Instrumentation and Methods for AstrophysicsOrder (ring theory)Instrumentation and Detectors (physics.ins-det)chemistryHigh Energy Physics::Experimentbusiness
researchProduct

Online 222 Rn removal by cryogenic distillation in the XENON100 experiment

2017

We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column was integrated into the gas purification loop of the XENON100 detector for online radon removal. This enabled us to significantly reduce the constant 222 Rn background originating from radon emanation. After inserting an auxiliary 222 Rn emanation source in the gas loop, we determined a radon reduction factor of R>27 (95% C.L.) for the distillation column by monitoring the 222 Rn activity concentration inside the XENON100 detector.

XenonPhysics and Astronomy (miscellaneous)WimpDirect SearchDark MatterTPCEngineering (miscellaneous)European Physical Journal C
researchProduct

Constraining the spin-dependent WIMP-nucleon cross sections with XENON1T

2019

We report the first experimental results on spin-dependent elastic weakly interacting massive particle (WIMP) nucleon scattering from the XENON1T dark matter search experiment. The analysis uses the full ton year exposure of XENON1T to constrain the spin-dependent proton-only and neutron-only cases. No significant signal excess is observed, and a profile likelihood ratio analysis is used to set exclusion limits on the WIMP-nucleon interactions. This includes the most stringent constraint to date on the WIMP-neutron cross section, with a minimum of 6.3 × 10−42 cm2 at 30 GeV/c2 and 90% confidence level. The results are compared with those from collider searches and used to exclude new paramet…

WIMP nucleon: interactionWIMP nucleon: scatteringParticle physicsCosmology and Nongalactic Astrophysics (astro-ph.CO)IsoscalarDark matterNuclear TheoryMassive particleGeneral Physics and AstronomyFOS: Physical sciencesParameter spacedark matter: direct detectionGravitation and Astrophysicsspin: dependence01 natural scienceslaw.inventionHigh Energy Physics - Phenomenology (hep-ph)WIMPlawisoscalar0103 physical sciencesS046DM1mediation010306 general physicsColliderPseudovectorPhysicsS030DN2S030DN1S030DP3S030DN3S030DP2S030DP1WIMP nucleon: cross sectionaxial-vectorHigh Energy Physics - PhenomenologyWIMPs Spin Dependent Cross Sections Neutron Cross Sections Likelihood methoddark matter: scattering[PHYS.HPHE]Physics [physics]/High Energy Physics - Phenomenology [hep-ph]High Energy Physics::ExperimentNucleon[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]Astrophysics - Cosmology and Nongalactic Astrophysicsexperimental results
researchProduct

Search for Coherent Elastic Scattering of Solar B8 Neutrinos in the XENON1T Dark Matter Experiment

2021

We report on a search for nuclear recoil signals from solar $^8$B neutrinos elastically scattering off xenon nuclei in XENON1T data, lowering the energy threshold from 2.6 keV to 1.6 keV. We develop a variety of novel techniques to limit the resulting increase in backgrounds near the threshold. No significant $^8$B neutrino-like excess is found in an exposure of 0.6 t $\times$ y. For the first time, we use the non-detection of solar neutrinos to constrain the light yield from 1-2 keV nuclear recoils in liquid xenon, as well as non-standard neutrino-quark interactions. Finally, we improve upon world-leading constraints on dark matter-nucleus interactions for dark matter masses between 3 GeV/…

Elastic scatteringPhysicsPhysics::Instrumentation and DetectorsScatteringAstrophysics::High Energy Astrophysical PhenomenaSolar neutrinoDark matterGeneral Physics and Astronomychemistry.chemical_element01 natural sciences7. Clean energyNuclear physicsXenonRecoilchemistry0103 physical sciencesHigh Energy Physics::ExperimentNeutrinoNuclear Experiment010306 general physicsOrder of magnitudePhysical Review Letters
researchProduct

Search for inelastic scattering of WIMP dark matter in XENON1T

2021

We report the results of a search for the inelastic scattering of weakly interacting massive particles (WIMPs) in the XENON1T dark matter experiment. Scattering off $^{129}$Xe is the most sensitive probe of inelastic WIMP interactions, with a signature of a 39.6 keV de-excitation photon detected simultaneously with the nuclear recoil. Using an exposure of 0.89 tonne-years, we find no evidence of inelastic WIMP scattering with a significance of more than 2$\sigma$. A profile-likelihood ratio analysis is used to set upper limits on the cross-section of WIMP-nucleus interactions. We exclude new parameter space for WIMPs heavier than 100 GeV/c${}^2$, with the strongest upper limit of $3.3 \time…

xenon: targetPhotonPhysics::Instrumentation and DetectorsParameter space01 natural sciencesWIMP: dark matterHigh Energy Physics - Experiment; High Energy Physics - Experiment; astro-ph.COHigh Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)XENONRecoilWIMPWIMP nucleus: cross section[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Dark Matterparameter spaceNuclear ExperimentComputingMilieux_MISCELLANEOUSnucleus: recoilPhysicsDark Matter Inelastic scattering XENON Direct Dark MatterPhysicsphotonAstrophysics::Instrumentation and Methods for AstrophysicsDirect Dark MatterWeakly interacting massive particlesastro-ph.COsignatureAstrophysics - Cosmology and Nongalactic AstrophysicsParticle physicsInelastic scatteringCosmology and Nongalactic Astrophysics (astro-ph.CO)Dark matterFOS: Physical sciencesWIMP: massAstrophysics::Cosmology and Extragalactic AstrophysicsInelastic scatteringNOPE2_2PE2_10103 physical sciencesddc:530010306 general physics010308 nuclear & particles physicsScatteringWIMP nucleus: interactionDarkmatterWIMP: interactionHigh Energy Physics::Experiment[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]Astrophysics and astroparticle physicsexperimental resultsPhysical Review D. Particles, Fields, Gravitation, and Cosmology
researchProduct

The XENON1T Dark Matter Experiment

2017

The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2 t liquid xenon inventory, 2.0 t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomultipliers. This article describes the XENON1T instrument and its subsystems as well as strategies to achieve an unprecedented low background level. First results on the detector response and the performance of the subsystems are also presented. © 2017, The Author(s).

xenon: targetPhotomultiplierCosmology and Nongalactic Astrophysics (astro-ph.CO)Physics - Instrumentation and DetectorsPhysics and Astronomy (miscellaneous)WIMP[ PHYS.ASTR ] Physics [physics]/Astrophysics [astro-ph]Dark matterchemistry.chemical_elementFOS: Physical scienceslcsh:Astrophysics01 natural sciencesHigh Energy Physics - ExperimentNuclear physicsHigh Energy Physics - Experiment (hep-ex)XENONXenonbackground: lowWIMP[ PHYS.HEXP ] Physics [physics]/High Energy Physics - Experiment [hep-ex]Ionization0103 physical scienceslcsh:QB460-466[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Dark Matterlcsh:Nuclear and particle physics. Atomic energy. Radioactivity[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsEngineering (miscellaneous)Instrumentation and Methods for Astrophysics (astro-ph.IM)[ PHYS.PHYS.PHYS-INS-DET ] Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]AstrophysiquePhysicsScintillationxenon: liquidTime projection chamberphotomultiplier010308 nuclear & particles physicsDetectorInstrumentation and Detectors (physics.ins-det)dark matter: detectortime projection chamberchemistrylcsh:QC770-798TPCAstrophysics - Instrumentation and Methods for Astrophysics[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]performanceAstrophysics - Cosmology and Nongalactic AstrophysicsEuropean Physical Journal C
researchProduct

Online $$^{222}$$ 222 Rn removal by cryogenic distillation in the XENON100 experiment

2017

researchProduct

First Results on the Scalar WIMP-Pion Coupling, Using the XENON1T Experiment

2018

We present first results on the scalar coupling of weakly interacting massive particles (WIMPs) to pions from 1 t yr of exposure with the XENON1T experiment. This interaction is generated when the WIMP couples to a virtual pion exchanged between the nucleons in a nucleus. In contrast to most nonrelativistic operators, these pion-exchange currents can be coherently enhanced by the total number of nucleons and therefore may dominate in scenarios where spin-independent WIMP-nucleon interactions are suppressed. Moreover, for natural values of the couplings, they dominate over the spin-dependent channel due to their coherence in the nucleus. Using the signal model of this new WIMP-pion channel, …

Nuclear TheoryPhysics::Instrumentation and DetectorsNuclear TheoryGeneral Physics and Astronomy01 natural sciencesHigh Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)High Energy Physics - Phenomenology (hep-ph)WIMPPions[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Nuclear ExperimentS030UDMPhysicsStarke Wechselwirkung und exotische Kerne – Abteilung BlaumAstrophysics::Instrumentation and Methods for AstrophysicsnucleonsuppressionHigh Energy Physics - PhenomenologyWeakly interacting massive particlesmedicine.anatomical_structureWeakly interacting massive particlesNucleonCoherence (physics)Astrophysics - Cosmology and Nongalactic AstrophysicsWIMP nucleon: interactionParticle physicsCosmology and Nongalactic Astrophysics (astro-ph.CO)[PHYS.NUCL]Physics [physics]/Nuclear Theory [nucl-th]FOS: Physical sciencesWIMP: massspin: dependenceGravitation and Astrophysicsoperator: nonrelativisticDark matter Particle dark matter Pions Weakly interacting massive particles Dark matter detectorsNuclear Theory (nucl-th)PionParticle dark matter0103 physical sciencesmedicineDark mattercross section: upper limit010306 general physicsCouplingDark matter detectorsnucleusScalar (physics)coherenceDark Matter WIMP-Pion coupling Xenon Direct seartch[PHYS.HPHE]Physics [physics]/High Energy Physics - Phenomenology [hep-ph]High Energy Physics::Experiment[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]Nucleus
researchProduct

Removing krypton from xenon by cryogenic distillation to the ppq level

2017

The XENON1T experiment aims for the direct detection of dark matter in a detector filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the β -emitter 85 Kr which is present in the xenon. For XENON1T a concentration of natural krypton in xenon natKr/Xe<200ppq (parts per quadrillion, 1 ppq =10−15mol/mol) is required. In this work, the design, construction and test of a novel cryogenic distillation column using the common McCabe–Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4⋅10⁵ with thermodynamic stabili…

7. Clean energy
researchProduct

XENON100 dark matter results from a combination of 477 live days

2016

We report on WIMP search results of the XENON100 experiment, combining three runs summing up to 477 live days from January 2010 to January 2014. Data from the first two runs were already published. A blind analysis was applied to the last run recorded between April 2013 and January 2014 prior to combining the results. The ultra-low electromagnetic background of the experiment, ~$5 \times 10^{-3}$ events/(keV$_{\mathrm{ee}}\times$kg$\times$day) before electronic recoil rejection, together with the increased exposure of 48 kg $\times$ yr improves the sensitivity. A profile likelihood analysis using an energy range of (6.6 - 43.3) keV$_{\mathrm{nr}}$ sets a limit on the elastic, spin-independe…

Scattering cross-sectionPhysicsCosmology and Nongalactic Astrophysics (astro-ph.CO)Physics - Instrumentation and DetectorsProton010308 nuclear & particles physicsDark matterFOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)01 natural sciences7. Clean energyXENON DARK MATTER WIMP TPCNuclear physicsRecoilWIMPLikelihood analysis0103 physical sciences[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Sensitivity (control systems)010306 general physicsEnergy (signal processing)Astrophysics - Cosmology and Nongalactic AstrophysicsPhysical Review D
researchProduct

DARWIN: Towards the ultimate dark matter detector

2016

DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible background. The prompt scintillation light and the charge signals induced by particle interactions in the xenon will be observed by VUV sensitive, ultra-low background photosensors. Besides its excellent sensitivity to WIMPs above a mass of 5 GeV/c2, such a detector with its large mass, low-energy …

Physics - Instrumentation and DetectorsPhysics::Instrumentation and Detectorsdouble beta decay7. Clean energy01 natural sciencesHigh Energy Physics - ExperimentPhysics Particles & FieldsNeutrino detectorHigh Energy Physics - Experiment (hep-ex)XenonWIMPPHOTOMULTIPLIERAXIONSphysics.ins-detsolar and atmospheric neutrinosPhysicsDark matter detectorTime projection chamberdark matter detectorsPhysicsSolar and atmospheric neutrinoInstrumentation and Detectors (physics.ins-det)Nuclear & Particles PhysicsNeutrino detectorSOLAR NEUTRINOSGASPhysical SciencesNeutrinoAstrophysics - Instrumentation and Methods for AstrophysicsGRAN SASSODark matter detectors; Double beta decay; Neutrino detectors; Solar and atmospheric neutrinosDark matterchemistry.chemical_elementFOS: Physical sciencesAstronomy & AstrophysicsLIQUID-XENON DETECTOR0202 Atomic Molecular Nuclear Particle And Plasma PhysicsSettore FIS/05 - Astronomia e AstrofisicaSEARCH0103 physical sciencesIsotopes of xenonZEPLIN-III[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsAxionInstrumentation and Methods for Astrophysics (astro-ph.IM)Science & Technology010308 nuclear & particles physicshep-exAstronomyAstronomy and Astrophysics0201 Astronomical And Space ScienceschemistryHigh Energy Physics::ExperimentSCINTILLATIONneutrino detectorsastro-ph.IMJournal of Cosmology and Astroparticle Physics
researchProduct

Online ^{222}Rn removal by cryogenic distillation in the XENON100 experiment

2017

International audience; We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column was integrated into the gas purification loop of the XENON100 detector for online radon removal. This enabled us to significantly reduce the constant$^{222}$ Rn background originating from radon emanation. After inserting an auxiliary$^{222}$ Rn emanation source in the gas loop, we determined a radon reduction factor of $R\,>\,27$ (95% C.L.) for the distillation column by monitoring the$^{222}$ Rn activity concentration inside the XENON100 detector.

xenon: liquidradon: admixturePhysics - Instrumentation and DetectorsPhysicsFOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)XENONmonitoringefficiencycryogenicsgasddc:530[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]background: radioactivity[ PHYS.PHYS.PHYS-INS-DET ] Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]
researchProduct