0000000001035096

AUTHOR

Stephan Achenbach

Everolimus eluting bioresorbable vascular scaffolds in patients with acute coronary syndromes: Two‐year results from the German‐Austrian ABSORB registry

Abstract Objectives To identify potential differences in 2‐year outcome between patients who underwent coronary revascularization using bioresorbable vascular scafffolds (BVS) in stable coronary artery disease (CAD) and acute coronary syndromes (ACS). Background Data from randomized trials suggest a significantly higher event rate following coronary revascularization using everolimus‐eluting BVS as compared to new generation drug eluting stents. Whether particular patient subgroups are at increased risk for scaffold thrombosis and target lesion failure (TLF) has not clearly been demonstrated. Methods German‐Austrian ABSORB RegIstRy is a prospective all‐comer multi‐center observational study…

research product

Coronary Stent Strut Fractures: Classification, Prevalence and Clinical Associations

Introduction. The frequency, characteristics and clinical implications of Strut fractures (SFs) remain incompletely understood. Methods and results. A total of 185 (160 patients) newer-generation drug-eluting stents (DES) were imaged. SFs were found in 21 DES (11.4%) and were classified in four patterns: one single stacked strut (41%)

research product

Predictors of early scaffold thrombosis: results from the multicenter prospective German-Austrian ABSORB RegIstRy.

BACKGROUND In randomized clinical trials, the risk of thrombotic events with the absorb bioresorbable vascular scaffold (BVS) was significantly higher than with metallic drug-eluting stents. We evaluated predictors of scaffold thrombosis in the large-scale, multicenter German-Austrian ABSORB RegIstRy. METHODS AND RESULTS 3178 patients with treatment of 4252 lesions using 5020 scaffolds were included. Follow-up rate at 6 months was 97.4%. Forty-five (1.42%) patients experienced definite/probable scaffold thrombosis during follow-up. Multiple regression analysis showed implantation of absorb BVS in bifurcation lesions [odds ratio (OR): 4.43; 95% confidence interval (CI): 1.69-11.59; P=0.0024]…

research product

European Society of Cardiology

Abstract Aims This report from the European Society of Cardiology (ESC) Atlas Project updates and expands upon the widely cited 2019 report in presenting cardiovascular disease (CVD) statistics for the 57 ESC member countries. Methods and results Statistics pertaining to 2019, or the latest available year, are presented. Data sources include the World Health Organization, the Institute for Health Metrics and Evaluation, the World Bank, and novel ESC sponsored data on human and capital infrastructure and cardiovascular healthcare delivery. New material in this report includes sociodemographic and environmental determinants of CVD, rheumatic heart disease, out-of-hospital cardiac arrest, left…

research product

Predictors of scaffold failure and impact of optimized scaffold implantation technique on outcome: Results from the German-Austrian ABSORB RegIstRy.

Aims We aimed to investigate predictors of scaffold failure and the potential impact of an optimized scaffold implantation technique by means of a learning curve on long-term clinical outcome after bioresorbable scaffold (BRS) implantation and to evaluate predictors of scaffold failure. Methods and results A total of 3326 patients were included in this prospective, observational, multi-center study (ClinicalTrials.gov NCT02066623) of consecutive patients undergoing BRS implantation between November 2013 and January 2016. The 3144 patients completed follow-up after 24 months, 3265 patients were eligible for time-to-event-analysis. Clinical endpoints were major adverse cardiac events-a compos…

research product

TCT-350 Safety and Performance of the Resorbable Magnesium Scaffold, Magmaris in a Real World Setting - First 400 Subjects at 12-month Follow-up of the BIOSOLVE-IV Registry

The aim of this registry is to investigate the clinical performance and long-term safety of the Resorbable Magnesium Scaffold (Magmaris) (BIOTRONIK AG, Buelach, Switzerland) in a real-world setting. Up to 2,054 subjects in up to 120 clinical sites in Europe, Asia, and Asia-Pacific countries will

research product

Determination of optimal fluoroscopic angulations for aorto-coronary ostial interventions from coronary computed tomography angiography.

Abstract Background An optimal aorto-coronary angiographic projection, characterized by an orthogonal visualization of the proximal coronary artery, is crucial for interventional success. We determined the distribution of optimal C-arm positions and assessed their feasibility by invasive coronary angiography. Methods Orthogonal aorto-coronary ostial angulations were determined in 310 CT data sets. In 100 patients undergoing subsequent invasive angiography, we assessed if the CT-predicted angulations were achievable by the C-arm system. If the predicted projection was not achievable due to mechanical constraints of the C-arm system, the most close, achievable angulation was determined. Patie…

research product

No difference in 30-day outcome and quality of life in transradial versus transfemoral access – results from the German Austrian ABSORB registry (GABI-R)

Abstract Background Radial (RA) instead of femoral access (FA) for coronary interventions has become a European Society of Cardiology Class-IA guideline recommendation. But when the decision on the access site is left to the discretion of the operator, differences in adverse event rates mitigate. Methods We compared the 30-day outcome for RA and FA in all patients recruited for the observational German Austrian ABSORB Registry (GABI-R) in regard to all-cause mortality, stroke, myocardial infarction (MI), TIMI major bleedings (TMB) and quality of life (QoL). All patients were treated with a bioresorbable vascular scaffold. Access site was left to the discretion of the operator. Results In to…

research product

Absorb Bioresorbable Scaffold Versus Xience Metallic Stent for Prevention of Restenosis Following Percutaneous Coronary Intervention in Patients at High Risk of Restenosis: Rationale and Design of the COMPARE ABSORB Trial

Abstract Background The advent of bioresorbable vascular scaffolds (BVS) was considered as a potential improvement in percutaneous coronary intervention (PCI) after the groundbreaking development of drug eluting stents (DES). However, the clinical performance, long-term safety and efficacy of BVS in complex coronary lesions remain uncertain. COMPARE ABSORB, a multicenter, single blind, prospective randomized trial, aims to compare the clinical outcomes between the Absorb BVS and Xience everolimus-eluting metallic stent (EES) in patients with coronary artery disease and a high risk of restenosis. Design COMPARE ABSORB is designed to enroll 2100 patients at up to 45 European sites. Enrolled p…

research product

Contemporary practice and technical aspects in coronary intervention with bioresorbable scaffolds : a European perspective

Aims Next to patient characteristics, the lack of a standardised approach for bioresorbable vascular scaffold (BVS) implantation is perceived as a potential explanation for the heterogeneous results reported so far. To provide some guidance, we sought to find a consensus on the best practices for BVS implantation and management across a broad array of patient and lesion scenarios. Methods and results Fourteen European centres with a high volume of BVS procedures combined their efforts in an informal collaboration. To get the most objective snapshot of different practices among the participating centres, a survey with 45 multiple choice questions was prepared and conducted. The results of th…

research product

2014 ESC Guidelines on the diagnosis and management of acute pulmonary embolism

ACS : acute coronary syndrome AMPLIFY : Apixaban for the Initial Management of Pulmonary Embolism and Deep-Vein Thrombosis as First-line Therapy aPTT : activated partial thromboplastin time b.i.d. : bis in diem (twice daily) b.p.m. : beats per minute BNP : brain natriuretic peptide BP : blood pressure CI : confidence interval CO : cardiac output COPD : chronic obstructive pulmonary disease CPG : Committee for Practice Guidelines CRNM : clinically relevant non-major CT : computed tomographic/tomogram CTEPH : chronic thromboembolic pulmonary hypertension CUS : compression venous ultrasonography DSA : digital subtraction angiography DVT : deep vein thrombosis ELISA : enzyme-linked immunosorben…

research product

Hybrid Coronary Percutaneous Treatment with Metallic Stents and Everolimus-Eluting Bioresorbable Vascular Scaffolds: 2-years Results from the GABI-R Registry

The limitations of the first-generation everolimus-eluting coronary bioresorbable vascular scaffolds (BVS) have been demonstrated in several randomized controlled trials. Little data are available regarding the outcomes of patients receiving hybrid stenting with both BVS and drug-eluting stents (DES). Of 3144 patients prospectively enrolled in the GABI-Registry, 435 (age 62 &plusmn

research product

P2695ABSORB bioresorbable scaffold versus Xience metallic stent in acute coronary syndromes with treated with percutaneous coronary intervention. A subanalysis of the COMPARE-ABSORB trial

Abstract Background The safety and efficacy of the ABSORB scaffold in ACS patients remain unclear. The COMPARE-ABSORB trial compares the ABSORB to the Xience stent in lesions and patients at high risk for restenosis Patients with STEMI and urgent PCI for non-STEMI were not excluded. Methods Patients included in the COMPARE-ABSORB trial undergoing PCI for ACS were eligible. Predefined implantation techniques for ABSORB was mandatory. Primary endpoint is target lesion failure (TLF) at 1 year, defined as a composite of cardiac death, target vessel myocardial infarction and clinically indicated target lesion revascularization. Results Of 1670 patients, 842 were treated for ACS. At 1-year, TLF o…

research product

Impact of coronary calcification on outcomes after ABSORB scaffold implantation: insights from the GABI-R registry.

OBJECTIVE To investigate the outcomes after bioresorbable scaffold (BRS) implantation in calcified coronary lesions. In calcified coronary lesions, durable metallic drug-eluting stent (DES) implantation is associated with worse clinical outcomes compared to noncalcified lesions. Although not recommended, BRSs were frequently implanted in calcified lesions in clinical practice. Their outcome is not well investigated. METHODS Between November 2013 and January 2016, 3326 patients were enrolled in the German-Austrian ABSORB ReglstRy (GABI-R). Lesion calcification severity was classified into no (n = 1144), mild (n = 1306), and moderate-to-severe (n = 690) calcification. RESULTS Patients with ca…

research product