0000000001054784

AUTHOR

R. Savreux

showing 5 related works from this author

Cadmium mass measurements between the neutron shell closures at N=50 and 82

2010

International audience; The mass values of the neutron-deficient cadmium isotopes 99−109Cd and of the neutronrich isotopes 114,120,122−124,126,128Cd have been measured using ISOLTRAP. The behavior of the separation energies of the cadmium isotopes from N = 50 to 82 is discussed.

CadmiumIsotopehigh-precision mass measurementsChemistryStable isotope ratioPenning trapRadiochemistrychemistry.chemical_element020206 networking & telecommunications02 engineering and technology[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]ISOLTRAP7. Clean energyISOLTRAPcadmium massesIsotope separationlaw.inventionlawIsotopes of cadmium0202 electrical engineering electronic engineering information engineering020201 artificial intelligence & image processingNeutron21.10.Dr 21.30.Fe 27.60.+j 32.10.BiNucleon
researchProduct

Towards a magnetic field stabilization at ISOLTRAP for high-accuracy mass measurements on exotic nuclides

2008

Abstract The field stability of a mass spectrometer plays a crucial role in the accuracy of mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of fluctuations are temperature variations in the vicinity of the trap and pressure changes in the liquid helium cryostat of the superconducting magnet. Thus systems for the temperature and pressure stabilization of the Penning trap mass spectrometer ISOLTRAP at the ISOLDE facility at CERN have been installed. A reduction of the temperature and pressure fluctuations by at least an order of magnitude down to Δ T ≈ ± 5 mK and Δ p ≈ ± 5 Pa has been achieved, which corresponds to a relative magn…

PhysicsNuclear and High Energy PhysicsSpectrometerLiquid heliumSuperconducting magnetMass spectrometryPenning trapISOLTRAPlaw.inventionNuclear physicslawIon trapNuclear ExperimentInstrumentationHybrid mass spectrometer
researchProduct

Time-separated oscillatory fields for high-precision mass measurements on short-lived Al and Ca nuclides

2008

High-precision Penning trap mass measurements on the stable nuclide 27Al as well as on the short-lived radionuclides 26Al and 38,39Ca have been performed by use of radiofrequency excitation with time-separated oscillatory fields, i.e. Ramsey's method, as recently introduced for the excitation of the ion motion in a Penning trap, was applied. A comparison with the conventional method of a single continuous excitation demonstrates its advantage of up to ten times shorter measurements. The new mass values of 26,27Al clarify conflicting data in this specific mass region. In addition, the resulting mass values of the superallowed beta-emitter 38Ca as well as of the groundstate of the beta-emitte…

PhysicsRadionuclide010308 nuclear & particles physicsSpecific massGeneral Physics and AstronomyFOS: Physical sciences[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Penning trap01 natural sciencesIonStable nuclide0103 physical sciencesNuclear Physics - ExperimentNuclideAtomic physicsNuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentNuclear ExperimentExcitation
researchProduct

Approaching theN=82shell closure with mass measurements of Ag and Cd isotopes

2010

Mass measurements of neutron-rich Cd and Ag isotopes were performed with the Penning trap mass spectrometer ISOLTRAP. The masses of ${}^{112,114\ensuremath{-}124}$Ag and ${}^{114,120,122\ensuremath{-}124,126,128}$Cd, determined with relative uncertainties between $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}$ and $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}$, resulted in significant corrections and improvements of the mass surface. In particular, the mass of $^{124}\mathrm{Ag}$ was previously unknown. In addition, other masses that had to be inferred from $Q$ values of nuclear decays and reactions have now been measured directly. The analysis includes various mass…

PhysicsNuclear reactionNuclear and High Energy Physics010308 nuclear & particles physicsQ value21.10.Dr 21.30.Fe 27.60.+jHadron[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesISOLTRAPIsotopes of cadmium0103 physical sciencesIsotopes of tinNuclear Physics - ExperimentAtomic physics010306 general physicsNucleonEnergy (signal processing)Physical Review C
researchProduct

Magnetic field stabilization for high-accuracy mass measurements on exotic nuclides

2007

The magnetic-field stability of a mass spectrometer plays a crucial role in precision mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of instabilities are temperature fluctuations in the vicinity of the trap and pressure fluctuations in the liquid helium cryostat of the superconducting magnet. Thus systems for the temperature and pressure stabilization of the Penning trap mass spectrometer ISOLTRAP at the ISOLDE facility at CERN have been installed. A reduction of the fluctuations by at least one order of magnitude downto dT=+/-5mK and dp=+/-50mtorr has been achieved, which corresponds to a relative frequency change of 2.7x10^{-…

Physics - Instrumentation and DetectorsAtomic Physics (physics.atom-ph)FOS: Physical sciencesNuclear Physics - ExperimentInstrumentation and Detectors (physics.ins-det)Physics::Atomic PhysicsDetectors and Experimental TechniquesNuclear ExperimentPhysics - Atomic Physics
researchProduct