0000000001060904
AUTHOR
G. Suliman
showing 2 related works from this author
Precision Lifetime Measurements Using LaBr3 Detectors With Stable and Radioactive Beams
2013
A range of high resolution gamma-ray spectroscopy measurements have been carried out using arrays which include a number of Cerium-doped Lanthanum-Tribromide (LrBr3 (Ce)) scintillation detectors used in conjunction with high-resolution hyper-pure germanium detectors. Examples of the spectral and temporal responses of such set-ups, using both standard point radioactive sources 152 Eu and 56 Co, and in-beam fusionevaporation reaction experiments for precision measurements of nuclear excited states in 34 P and 138 Ce are presented. The current and future use of such arrays at existing (EURICA at RIKEN) and future (NUSTAR at FAIR) secondary radioactive beam facilities for precision measurements…
AGATA-Advanced GAmma Tracking Array
2012
WOS: 000300864200005