Long-term performance of the bovine pericardium patch in conventional carotid endarterectomy.
Objective The aim of the study was to analyze long-term results of carotid endarterectomy (CEA) using bovine pericardium patch. Patients and Methods This study is a retrospective analysis of 274 consecutive cases (173 in CEA group and 101 patients in an internal control group of eversion endarterectomy [EEA]) operated between January 2005 and May 2007. Operations were performed according to standard surgical technique. Primary endpoints of the study were 30-day mortality, ipsilateral neurologic event rate, and high-grade restenosis in the long-term follow-up. Results No statistically significance between both groups was found in terms of gender, age, risk factors, medication (statine, plate…