0000000001139616

AUTHOR

Marcelo Coelho Goiato

Bond strength of lithium disilicate after cleaning methods of the remaining hydrofluoric acid

Background Complex implant treatments have steadily increased within implant prosthodontics. Based on the lower implant mobility, implant impressions need high accuracy in the model transfer to receive a high passive fit within the final prosthodontic restoration. To analyze the accurate 3-dimensional (3D) inter-implant-positions, a reference point is indispensable. However, there is no reference in the patients mouth, so the aim of the present study was to develop a new method based on a custom-made-measuring-aid (CMA) to assess the inter implant dimensions (InID) in patients. Material and Methods Initially an implant master model (IMM/patient equivalent) was digitized by computed tomograp…

research product

Stress distribution in fixed mandibular prostheses fabricated by CAD/CAM and conventional techniques: Photoelastic and strain gauge analyses

Made available in DSpace on 2020-12-12T00:55:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2019-09-01 The aim of this study was to evaluate the distribution of stress in complete fixed mandibular prostheses with infrastructures (IE) fabricated with different materials and techniques, under compressive force. A model of an edentulous mandible, which received five 4x11 mm external hexagon implants between the mental foramens, was fabricated. The groups were divided into: Group I - IE in nickel-chromium with an acrylic resin occlusal coating; Group II - IE in nickel-chromium with a ceramic occlusal coating; Group III - IE milled in zirconia with a ceramic coating. For the photoelastic m…

research product

Masticatory efficiency, bite force and electrical activity of the masseter and temporalis muscles in bodybuilders

Made available in DSpace on 2022-04-29T08:32:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2021-09-01 Background: This study aimed to compare the masticatory efficiency, the maximum voluntary occlusal bite force (MVOBF) and the electrical activity (EMG) of masticatory muscles of practitioners of upper limb bodybuilding before and after physical activity. Methods: Twenty healthy individuals (10 men and 10 women, age from 18 to 30 (mean of 24.7 years old) without masticatory system disorders, that regularly practice hypertrophic physical activity were submitted to the analyses of masticatory efficiency, MVOBF, and surface EMG of the temporalis and masseter muscles. The masticatory effi…

research product