Calibration of misonidazole labeling by simultaneous measurement of oxygen tension and labeling density in multicellular spheroids
To correlate misonidazole concentrations and oxygen pressures (Po2) at identical locations within EMT6/Ro multi-cell spheroids (mean diameters +/- SD: 867 +/- 20 microns), Po2 measurements were performed with oxygen-sensitive microelectrodes during incubation of these spheroids with tritiated misonidazole (10 mg/I; 445 microCi/mg). In each individual spheroid, Po2 profiles were correlated with the corresponding spatial distribution of misonidazole as quantified by conventional autoradiography and grain counting. To compare the oxygenation status of spheroids in the measuring chamber with that of spheroids in spinner culture, misonidazole labeling was performed in both environments following…