FiberWire tension band for patellar fractures.
Background Symptomatic hardware represents the most frequent complication reported following surgical treatment of patellar fracture. For this reason, some authors suggested using nonabsorbable sutures to fix the fracture with various techniques. The aim of this study was to evaluate clinical and radiological results of patients treated following a modified Pyriford technique using a FiberWire suture (Arthrex, Naples, FL, USA). Materials and methods We retrospectively evaluated a case series of seventeen patients with displaced patellar fractures treated by open reduction and internal fixation with a modified tension band using FiberWire sutures. Clinical and radiological outcome were eval…