0000000001180563

AUTHOR

M. Aiello

showing 11 related works from this author

A low cost and easy re-configurable instrument for power quality survey

2004

In this document the development of a low cost and user friendly PC-based instrument for power quality measurement is proposed, according to IEC 61000-4-7 and standard IEC 61000-4-30. It is an easily re-configurable instrument able to measure harmonics, interharmonics and amplitude disturbances and supply unbalance. In order to verify its accuracy, the instrument has been tested according standard test procedures, by means of a built-up calibration test bench.

Measure (data warehouse)Total harmonic distortionEngineeringUser Friendlybusiness.industryElectromagnetic compatibilityDiscrete Fourier transformsReliability engineeringspectral leakageHarmonicsCalibrationElectronic engineeringPower qualityFrequency estimationbusinessVoltageProceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510)
researchProduct

A PC-based instrument for harmonics and interharmonics measurement in power supply systems

2004

Abstract Growing interest on power quality has led international working groups to define new standards for testing and measurement techniques to apply to power systems. Special attention has been paid to harmonic and interharmonic measurements. Here, the authors introduce a PC-based instrument capable of synchronising sampling frequency with fundamental frequency in order to perform on-line voltage or current distortion analysis. The instrument has been developed in accordance with currently available standards and international documents, IEC 61000-4-7 Ed. 2002, IEC 61000-4-30 Ed. 2003, Draft Guide IEEE P1159.1 Ed. 2003 and limits given by IEC 61000 Part. 3. A detailed description of the …

Engineeringbusiness.industryApplied MathematicsElectrical engineeringFundamental frequencyCondensed Matter PhysicsDiscrete Fourier transformsPower (physics)spectral leakageElectric power systemHarmonicsElectronic engineeringHarmonicPower qualityFrequency estimationElectric powerElectrical and Electronic EngineeringbusinessInstrumentationVoltageMeasurement
researchProduct

Synchronization techniques for power quality instruments

2004

The measurement of voltage characteristics in power systems requires the accurate estimation of the power supply frequency and signal synchronization, even in the presence of disturbances. The authors developed and tested two innovative techniques for instrument synchronization. The first is based on signal spectral analysis techniques performed by means of the Chirp-Z transform analysis. The second is a phase-locked loop (PLL) software based on a time-domain coordinate transformation and an innovative phase-detection technique. To evaluate how synchronization techniques are adversely affected by the application of a disturbing influence, experimental tests were carried out, taking into acc…

EngineeringInstrument synchronization phase-locked loops (PLLs) power quality power system measurements spectral analysis.business.industryComputer scienceCoordinate systemControl engineeringFundamental frequencyPhase detectorSignalSynchronizationPower (physics)Phase-locked loopElectric power systemSoftwareChirpElectronic engineeringElectrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheInstrumentation
researchProduct

An induction motor speed measurement based on current harmonic analysis with Chirp-Z Transform

2002

The paper presents a new method to measure motor speed by means of frequency estimation of rotor slot harmonics present in the supply current of squirrel single cage induction motors. The novelty of the method is the use of Chirp-Z Transform as supply current harmonic analysis. The advantages are an improved spectral resolution and accuracy. Moreover a shorter sampling time window is required reducing errors related to not stationary current signal. Experimental results are presented to validate the proposed method and to perform a comparison with FFT based one.

EngineeringRotor (electric)business.industryBluestein's FFT algorithmFast Fourier transformSignallaw.inventionHarmonic analysislawHarmonicsChirpElectronic engineeringbusinessInduction motorIMTC 2001. Proceedings of the 18th IEEE Instrumentation and Measurement Technology Conference. Rediscovering Measurement in the Age of Informatics (Cat. No.01CH 37188)
researchProduct

Theoretical and Experimental Comparison of Total Harmonic Distortion Factors for the Evaluation of Harmonic and Interharmonic Pollution of Grid-Conne…

2006

Grid connected photovoltaic systems are increasingly used in electrical distribution systems. However, they inject distorted currents. Therefore special attention must be paid to harmonic and interharmonic measurements. The new edition of IEC 61000-4-7 introduces the concept of harmonic and interharmonic groups, which implies new expressions for Total Harmonic Distortion factors. In the paper a theoretical and experimental comparison is made between the different total harmonic distortion factors in order to show which of the currently defined distortion factors is best-suited to detect harmonic and interharmonic pollution. Experimental tests were carried out first by means of a calibrator …

Total harmonic distortionEngineeringbusiness.industryPhotovoltaic systemElectrical engineeringEnergy Engineering and Power TechnologyGridlaw.inventionHarmonic analysislawElectrical networkDistortionPersonal computerElectronic engineeringHarmonicElectrical and Electronic EngineeringbusinessGrid-connected photovoltaic systems harmonic and interharmonic analysis IEC 61000-4-7 Ed 2002.IEEE Transactions on Power Delivery
researchProduct

A chirp-z transform-based synchronizer for power system measurements

2005

In the last few years, increased interest in power and voltage quality has forced international working groups to standardize testing and measurement techniques. IEC 61000-4-30, which defines the characteristics of instrumentation for the measurement of power quality, refers to IEC 61000-4-7 for the evaluation of harmonics and interharmonics. This standard, revised in 2002, requires a synchronous sampling of voltage or current signal, in order to limit errors and to ensure reproducible results even in the presence of nonstationary signals. Therefore, an accurate estimation of the fundamental frequency is required, even in the presence of disturbances. In this paper, an algorithm to detect t…

Computer scienceBluestein's FFT algorithmFast Fourier transformChirp-z transform power quality synchronizationFundamental frequencyPower (physics)Electric power systemSampling (signal processing)SynchronizerHarmonicsElectronic engineeringElectrical and Electronic EngineeringInstrumentationSettore ING-INF/07 - Misure Elettriche E ElettronicheInterpolation
researchProduct

A self-synchronizing instrument for harmonic sources detection in power systems

2004

The deregulation of energy markets holds out new prospects for contract between customers and utilities, in which the price of energy can depend on voltage quality and load characteristics, as well as on the responsibility for disturbances caused to supply voltage in power systems. In this context, harmonic sources detection is one of the main problems, because of equipment sensibility and the proliferation of loads which absorb non-sinusoidal currents. In this paper the authors present a new instrument based on a time domain method for the detection of harmonic active powers in three-phase systems, which can be usefully applied even in the presence of unbalance or asymmetry. The amplitude …

Total harmonic distortionEngineeringComputer sciencebusiness.industryPhase angleElectrical engineeringSynchronizingContext (language use)AC powerElectric power systemAmplitudeQuality (physics)DistortionHarmonicElectronic engineeringTime domainElectrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheInstrumentationHarmonic analysis harmonic distortion phase locked loops (PLLs) power measurement power quality power system harmonics power system measurementsVoltage
researchProduct

Disability Management e culture organizzative: Verso la definizione di un modello di orientamento culturale dell’organizzazione verso la disabilità a…

2016

L’ultimo decennio ha visto indubbiamente aumentare la sensibilità delle aziende italiane nei confronti del Disability Management, inteso come un approccio strategico finalizzato alla valorizzazione e all’empowering dei lavoratori con disabilità. A fronte di questa crescente attestazione d’interesse, tradotta peraltro in sempre più numerose iniziative gestionali mirate, si riscontra tuttavia ad oggi una carenza di modelli che consentano di valutare se, e quanto, la cultura e i valori di un’organizzazione siano congruenti con l’implementazione e lo sviluppo di pratiche di gestione delle differenze legate alla disabilità, pienamente in linea con una logica di valorizzazione delle diverse abili…

Disability Management; Culture organizzative; Valori organizzativiSettore M-PSI/06 - Psicologia Del Lavoro E Delle OrganizzazioniValori organizzativiDisability ManagementCulture organizzative
researchProduct

Disability management in azienda: Il valore dei limiti

2017

L'articolo mira a definire il Diversity Management Disability in termini di cultura organizzativa, partendo da quello che è il senso del “Limite” e il suo superamento e spiegando in cosa consiste il Disability Management e il suo utilizzo.

Disability managementDiversity management; Disability management; Cultura organizzativaCultura organizzativaDiversity management
researchProduct

An induction motor speed measurement method based on current harmonic analysis with the Chirp-Z Transform

2005

This paper presents a new method to measure motor speed by means of frequency estimation of rotor slot spectral components in the supply current of squirrel single-cage induction motors. The novelty of the method consists in the harmonic analysis of the supply current by means of the chirp-Z transform (CZT). The advantages are improved accuracy due to better spectral resolution and resolvability. Moreover, a shorter observation window is required, thus reducing errors related to nonstationary current signals. The experimental results are presented to validate the proposed method and to make a comparison with a similar method based on the fast Fourier transform (FFT).

EngineeringRotor (electric)business.industryBluestein's FFT algorithmFast Fourier transformMotorsMeasure (mathematics)law.inventionHarmonic analysisefficiency estimationInduction motorslawElectronic engineeringElectrical and Electronic EngineeringSpectral resolutionCurrent (fluid)businessInstrumentationInduction motor
researchProduct

A fully-automated procedure for measuring the electrical parameters of an induction motor drive with rotor at standstill

2003

The paper presents an automatic procedure to measure at standstill the electrical parameters of an induction motor fed by a PWM voltage source inverter. The proposed procedure executes automatically three tests using only the available PWM inverter control technique to obtain the required motor supply voltages. It allows the measurement of all the T-form circuit electrical parameters starting from the nameplate data as data-entry. It uses only a current sensor and no voltage sensor and process on line the collected data samples with a fast and easy to implement recursive least squares algorithm. Effectiveness of the automated procedure has been proved both by simulation and experimental tes…

Recursive least squares filterEngineeringTest benchbusiness.industryRotor (electric)Control engineeringLine (electrical engineering)law.inventionControl theorylawEquivalent circuitCurrent sensorbusinessInduction motorVoltageIMTC/2002. Proceedings of the 19th IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.00CH37276)
researchProduct