0000000001252877

AUTHOR

D. Mayer

showing 8 related works from this author

21. Mainzer Allergie-Workshop

2009

03 medical and health sciencesmedicine.medical_specialty0302 clinical medicineOtorhinolaryngologybusiness.industryFamily medicinemedicineImmunology and Allergy030223 otorhinolaryngologybusiness030215 immunologyAllergo Journal
researchProduct

Sutureless Clampless Telescoping Method for Aortic and Arterial Anastomoses Using an Endograft Connector

2011

VORTEC anastomosis stuturelessSettore MED/22 - Chirurgia Vascolare
researchProduct

Complete renovisceral debranching and EVAR for thoracoabdominal aneurysm

2011

Open graft repair of thoracoabdominal aortic aneurysms (TAAA) is an incredibly complex and challenging procedure with acceptable results achieved only by a few centers worldwide. Contemporary outcome analysis of TAAA repair performed in the United States showed greater operative mortality and morbidity rates than commonly reported. Moreover, a recent European long-term follow-up study showed that survival remains suboptimal, especially in the early years after TAAA repair. Complete renovisceral debranching combined with EVAR offers many advantages in regard to open surgical repair with comparable or better results, especially in the high-risk patient. Although this hybrid procedure will not…

Settore MED/22 - Chirurgia VascolareComplete renovisceral debranching EVAR TAA
researchProduct

Determining gA/gV with High-Resolution Spectral Measurements Using a LiInSe2 Bolometer

2022

Neutrinoless double beta decay (0νββ) processes sample a wide range of intermediate forbidden nuclear transitions, which may be impacted by quenching of the axial vector coupling constant (gA/gV), the uncertainty of which plays a pivotal role in determining the sensitivity reach of 0νββ experiments. In this Letter, we present measurements performed on a high-resolution LiInSe2 bolometer in a “source = detector” configuration to measure the spectral shape of the fourfold forbidden β decay of 115In. The value of gA/gV is determined by comparing the spectral shape of theoretical predictions to the experimental β spectrum taking into account various simulated background components as well as a …

ydinfysiikka
researchProduct

Use of the STAT (Sutureless Telescoping Anastomosis Technique) to facilitate supraaortic revascularization: Mid-term Results

2016

sutureleSTATSTAT; telescopinng; sutureless; anastomosisanastomosisSettore MED/22 - Chirurgia Vascolaretelescopinng
researchProduct

The use of Endurant stent-graft for abdominal aortic aneurysm: the story about extension of instruction for use with persistent good results of stent…

2012

The Endurant stent-graft (Medtronic, Inc., Minneapolis, MN, USA) is a latest generation device for the treatment of abdominal aortic aneurysm. The idea behind designing such a graft came from the intention to broad the instruction for use (IFU) and to enable it to treat more challenging anatomy including the 10mm neck lengths, and more severe suprarenal and infrarenal angulations. Endurant stent-graft has active fixation through suprarenal stent with anchoring pins to provide migration resistance, optimized heights of stents and spacing between them for improved flexibility and conformability, low-profile delivery system with hydrophilic coating and controlled simple deployment mechanism. S…

Clinical Trials as TopicEvidence-Based Medicine10042 Clinic for Diagnostic and Interventional RadiologyEndovascular Procedures610 Medicine & healthProsthesis DesignRisk Assessment2705 Cardiology and Cardiovascular Medicine10020 Clinic for Cardiac Surgery2746 SurgeryBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationTreatment OutcomeRisk FactorsHumansStentsClinical CompetenceRegistriesLearning Curvestents endovascular procedures aortic aneurysm abdominalAortic Aneurysm Abdominal
researchProduct

How to diagnose and treat abdominal compartment syndrome after endovascular and open repair of ruptured abdominal aortic aneurysms

2014

Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are frequently encountered in patients treated for ruptured abdominal aortic aneurysms (rAAA) and carry a high morbidity and mortality risk. Despite these facts, IAH/ACS are still overlooked by many physicians, timely diagnosis is missed and treatment often inadequate. All staff involved in the treatment of rAAA should be aware of the risk factors predicting IAH/ACS, the profound implications and derangements on all organ systems, the clinical presentation, the appropriate measurement of intra-abdominal pressure to detect IAH/ACS and the current treatment options for these detrimental syndromes. This comprehensive r…

10042 Clinic for Diagnostic and Interventional Radiology610 Medicine & healthIntra-abdominal hypertension - Aortic aneurysm abdominal - Endovascular proceduresSettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular Medicine2746 Surgery
researchProduct

Tips and tricks to make the ascending aorta accessible to EVAR

2012

The ascending aorta is gaining increasing interest for endovascular specialists, as it opens the door to a potentially better way to treat aortic arch pathologies. Landing safely a stentgraft into the ascending aorta allows downgrading significantly the invasiveness of conventional open repair of the ascending aorta and/or aortic arch. Unfortunately, accessibility to the ascending aorta, in order to perform EVAR, can be challenging as the transfemoral approach might be cumbersome, or because the ascending aorta might not be appropriate for stentgraft landing. This paper will present some technical tips and tricks to achieve successful stentgraft landing in zone 0.

ascending aortaSettore MED/22 - Chirurgia Vascolare
researchProduct