The effect of Transient over Voltages on the Partial Discharges activity in HVDC joints
Rapid growth of HVDC cable line installations is expected in the coming years. Several research groups have investigated dielectric phenomena that occur in the insulation of HVDC cables and accessories that accelerate aging and reduce the reliability of this technology over time. Unlike in HVAC cables, under HVDC stress, the distribution of the electric field inside the insulation layer depends not only on the applied voltage but also on the temperature distribution and on other factors related to manufacturing such as the presence of impurities. Reaching local and transient electric field peaks can enhance the onset of Partial Discharges (PDs) which can lead to premature aging of the insul…