Abstract Background The safety and efficacy of the ABSORB scaffold in ACS patients remain unclear. The COMPARE-ABSORB trial compares the ABSORB to the Xience stent in lesions and patients at high risk for restenosis Patients with STEMI and urgent PCI for non-STEMI were not excluded. Methods Patients included in the COMPARE-ABSORB trial undergoing PCI for ACS were eligible. Predefined implantation techniques for ABSORB was mandatory. Primary endpoint is target lesion failure (TLF) at 1 year, defined as a composite of cardiac death, target vessel myocardial infarction and clinically indicated target lesion revascularization. Results Of 1670 patients, 842 were treated for ACS. At 1-year, TLF o…