0000000001284563

AUTHOR

J. Sabine Becker

showing 2 related works from this author

Depth profiling of Pu, 241Am and 137Cs in soils from southern Belarus measured by ICP-MS and alpha- and gamma-spectrometry

2003

The depth distribution of plutonium, americium, and Cs-137 originating front the 1986 accident at the Chernobyl Nuclear Power Plant (NPP) was investigated in several soil profiles in the vicinity from Belarus. The vertical migration of transuranic elements in soils typical of the 30 km relocation area around Chernobyl NPP was studied using inductively coupled plasma mass spectrometry (ICP-MS), alpha spectrometry, and gamma spectrometry. Transuranic concentrations in upper soil layers ranged from 6 x 10(-12) g g(-1) to 6 x 10(-10) g g(-1) for plutonium and from 1.8 x 10(-13) g g(-1) to 1.6 x 10(-11) g g(-1) for americium. These concentrations correspond to specific activities of Pu239+240 of…

chemistry.chemical_elementCesiumAmericiumManagement Monitoring Policy and LawMass spectrometryMass SpectrometrySoil Pollutants RadioactiveInductively coupled plasma mass spectrometryRadionuclideAmericiumRadiochemistryPublic Health Environmental and Occupational HealthGeneral MedicinePlutoniumPlutoniumJTransuranic wastechemistryCesium RadioisotopesEnvironmental chemistrySoil waterSoil horizonddc:333.7Radioactive Hazard ReleaseUkraineEnvironmental MonitoringPower Plants
researchProduct

Improvement of the detection limit for determination of 129I in sediments by quadrupole inductively coupled plasma mass spectrometer with collision c…

2004

The previously developed sample introduction device for the hot extraction of iodine from environmental samples (soils or sediments) and on-line introduction of analyte via the gas phase in quadrupole inductively coupled plasma mass spectrometry with hexapole collision cell (ICP-CC-QMS) was equipped with a cooling finger, which allowed intermediate iodine enrichment and improved the detection limits for I-129 down to 0.4 pg g(-1) without any additional sample preparation. A mixture of oxygen and helium as reaction gases in the hexapole collision cell was used for reducing the disturbing background intensity of Xe-129(+). Oxygen was also used as the carrier gas for iodine thermal desorption …

Detection limitChemistryAnalytical chemistryThermal desorptionchemistry.chemical_elementMass spectrometryJAnalytical Chemistryddc:540QuadrupoleSample preparationInductively coupled plasmaInductively coupled plasma mass spectrometrySpectroscopyHeliumJournal of Analytical Atomic Spectrometry
researchProduct