0000000001301575

AUTHOR

Antonio J. Del ÁGuila-carrasco

showing 24 related works from this author

Amplitude, Latency, and Peak Velocity in Accommodation and Disaccommodation Dynamics

2017

The aim of this work was to ascertain whether there are differences in amplitude, latency, and peak velocity of accommodation and disaccommodation responses when different analysis strategies are used to compute them, such as fitting different functions to the responses or for smoothing them prior to computing the parameters. Accommodation and disaccommodation responses from four subjects to pulse changes in demand were recorded by means of aberrometry. Three different strategies were followed to analyze such responses: fitting an exponential function to the experimental data; fitting a Boltzmann sigmoid function to the data; and smoothing the data. Amplitude, latency, and peak velocity of …

AdultArticle Subjectlcsh:MedicineEyeRefraction Ocular050105 experimental psychologyGeneral Biochemistry Genetics and Molecular Biology03 medical and health sciences0302 clinical medicineReaction TimeHumans0501 psychology and cognitive sciencesLatency (engineering)MathematicsGeneral Immunology and MicrobiologyPulse (signal processing)business.industrylcsh:R05 social sciencesMathematical analysisWork (physics)Accommodation OcularGeneral MedicineSigmoid functionExponential functionAmplitude030221 ophthalmology & optometrybusinessAccommodationSmoothingResearch ArticleBioMed Research International
researchProduct

Evaluation of the iridocorneal angle with accommodation using optical coherence tomography

2017

The changes in the iridocorneal angle structure during accommodation are assessed by means of anterior segment optical coherence tomography. Thirteen right eyes were included in the study. The device used for the measurement was the Visante® omni system. The stimuli were set up at different vergences (0.0 D, -1.5 D, and -3.0 D). The angle opening distance 500 and 750, the trabecular iris space area 500 and 750, and the scleral spur angle parameters were assessed at the nasal and temporal regions. The results in the iridotrabecular angle comparing the three accommodative states of the eye did not yield any statistically significant difference at nasal or temporal angle sections. In light of …

accommodationmedicine.medical_specialtygenetic structuresiridocorneal angleScleral spuranterior segment03 medical and health sciences0302 clinical medicineOptical coherence tomographylcsh:OphthalmologyOphthalmologyMedicineIris (anatomy)Iridocorneal angleoptical coherence tomographymedicine.diagnostic_testbusiness.industryBrief ReportSignificant differenceOphthalmologymedicine.anatomical_structurelcsh:RE1-994Temporal Regions030221 ophthalmology & optometrysense organs1616businessAccommodation030217 neurology & neurosurgeryInternational Journal of Ophthalmology
researchProduct

Effect of Phenylephrine on the Accommodative System

2016

Accommodation is controlled by the action of the ciliary muscle and mediated primarily by parasympathetic input through postganglionic fibers that originate from neurons in the ciliary and pterygopalatine ganglia. During accommodation the pupil constricts to increase the depth of focus of the eye and improve retinal image quality. Researchers have traditionally faced the challenge of measuring the accommodative properties of the eye through a small pupil and thus have relied on pharmacological agents to dilate the pupil. Achieving pupil dilation (mydriasis) without affecting the accommodative ability of the eye (cycloplegia) could be useful in many clinical and research contexts. Phenylephr…

medicine.medical_specialtygenetic structuresReview ArticlePupil03 medical and health sciences0302 clinical medicinelcsh:OphthalmologymedicinePupillary responseMydriasisbusiness.industryCycloplegiaPhenylephrine Hydrochlorideeye diseasesSurgeryOphthalmologymedicine.anatomical_structureCiliary musclelcsh:RE1-994030221 ophthalmology & optometryOptometryHuman eyesense organsmedicine.symptombusinessAccommodation030217 neurology & neurosurgeryJournal of Ophthalmology
researchProduct

Accommodation Responds to Optical Vergence and Not Defocus Blur Alone.

2017

Purpose To determine whether changes in wavefront spherical curvature (optical vergence) are a directional cue for accommodation. Methods Nine subjects participated in this experiment. The accommodation response to a monochromatic target was measured continuously with a custom-made adaptive optics system while astigmatism and higher-order aberrations were corrected in real time. There were two experimental open-loop conditions: vergence-driven condition, where the deformable mirror provided sinusoidal changes in defocus at the retina between -1 and +1 diopters (D) at 0.2 Hz; and blur-driven condition, in which the level of defocus at the retina was always 0 D, but a sinusoidal defocus blur …

AdultMalegenetic structuresVisual AcuityVergenceAstigmatismRefraction Ocular050105 experimental psychologyDeformable mirror03 medical and health sciences0302 clinical medicineOpticsmedicineHumans0501 psychology and cognitive sciencesAdaptive opticsDioptreMathematicsWavefrontbusiness.industry05 social sciencesAccommodation OcularAstigmatismConvergence Ocularmedicine.diseaseeye diseases030221 ophthalmology & optometryFemalesense organsMonochromatic colorCuesbusinessAccommodationPhotic StimulationInvestigative ophthalmologyvisual science
researchProduct

Assessment of corneal morphological changes induced by the use of daily disposable contact lenses.

2015

To assess the effect of different disposable soft contact lenses upon corneal thickness, and upon anterior and posterior corneal curvatures using a dual-Scheimpflug imaging based device.Twenty-eight young, healthy subjects wore four different types of daily disposable soft contact lenses on four different days: Dailies Total1, Proclear 1 Day, Clariti 1-Day and 1-Day Acuvue Moist. The lenses had different material and water content. Pachymetry maps and keratometry values were obtained using the Galilei G4 twice a day: one before putting the lens on and one after an eight-hour period of contact-lens wear. Measurements were also recorded without any contact lenses being worn during a day.Clari…

AdultMaleVisual Acuitylaw.inventionCorneaYoung AdultlawMyopiaMedicineHumansDisposable EquipmentKeratometerCorneal curvaturebusiness.industryHealthy subjectsCorneal TopographyGeneral MedicineEquipment DesignContact Lenses Hydrophiliceye diseasesContact lensLens (optics)OphthalmologyOptometryDaily disposableFemalesense organsThickeningbusinessOptometryFollow-Up StudiesContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Assessment of modifications in thickness, curvatures, and volume upon the cornea caused by disposable soft contact lens wear.

2015

Purpose To assess the effect of different disposable soft contact lenses on several corneal parameters–-thickness, anterior and posterior curvature, and volume–-by means of a Scheimpflug imaging-based device (Pentacam HR). Diurnal variations of these parameters were taken into account. Methods Twenty-one young, healthy subjects wore 4 different types of daily disposable soft contact lenses on 4 different days: Dailies AquaComfort Plus, SofLens, Dailies Total1, and Acuvue TruEye. The lenses had different material and water content. Pachymetry and curvature maps and corneal volume values were obtained using the Pentacam HR twice a day: one before putting the lens on and one after an 8-hour pe…

AdultMaleEffects of long-term contact lens wear on the corneaMaterials sciencegenetic structuresCorneal PachymetryScheimpflug principleVisual AcuityCurvatureCorneaYoung AdultOpticsCorneamedicineMyopiaHumansCorneal pachymetryDisposable Equipmentmedicine.diagnostic_testbusiness.industryCorneal TopographyGeneral MedicineOrgan SizeCorneal topographyContact Lenses Hydrophiliceye diseasesCircadian RhythmContact lensOphthalmologymedicine.anatomical_structureFemalesense organsDisposable EquipmentbusinessBiomedical engineeringEuropean journal of ophthalmology
researchProduct

Opto-mechanical artificial eye with accommodative ability.

2015

The purpose of this study was to describe the design and characterization of a new opto-mechanical artificial eye (OMAE) with accommodative ability. The OMAE design is based on a second-pass configuration where a small source of light is used at the artificial retina plane. A lens whose focal length can be changed electronically was used to add the accommodation capability. The changes in the OMAE's aberrations with the lens focal length, which effectively changes the accommodative state of the OMAE, were measured with a commercial aberrometer. Changes in power and aberrations with room temperature were also measured. The OMAE's higher-order aberrations (HOAs) were similar to the ones of th…

genetic structuresbusiness.industryComputer scienceeye diseasesAtomic and Molecular Physics and Opticslaw.inventionLens (optics)Spherical aberrationOpticsmedicine.anatomical_structurelawVisual accommodationmedicineFocal lengthHuman eyesense organsbusinessAccommodationOptics express
researchProduct

The effect of aberrations on objectively assessed image quality and depth of focus

2017

The effects of aberrations on image quality and the objectively assessed depth of focus (DoF) were studied. Aberrometry data from 80 young subjects with a range of refractive errors was used for computing the visual Strehl ratio based on the optical transfer function (VSOTF), and then, through-focus simulations were performed in order to calculate the objective DoF (using two different relative thresholds of 50% and 80%; and two different pupil diameters) and the image quality (the peak VSOTF). Both lower order astigmatism and higher order aberration (HOA) terms up to the fifth radial order were considered. The results revealed that, of the HOAs, the comatic terms (third and fifth order) ex…

AdultMaleDepth of focusCorneal Wavefront AberrationAdolescentImage qualityPopulationVisual AcuityComa (optics)Astigmatism050105 experimental psychologyYoung Adult03 medical and health sciences0302 clinical medicineOpticsOptical transfer functionAberrometrymedicineHumansComputer Simulation0501 psychology and cognitive scienceseducationVision OcularRetrospective StudiesMathematicsDepth Perceptioneducation.field_of_studybusiness.industryAberrometry05 social sciencesAstigmatismStrehl ratiomedicine.diseaseSensory SystemsOphthalmologyVisual Perception030221 ophthalmology & optometryFemalebusinessJournal of Vision
researchProduct

Human eyes do not need monochromatic aberrations for dynamic accommodation

2017

Purpose To determine if human accommodation uses the eye's own monochromatic aberrations to track dynamic accommodative stimuli. Methods Wavefront aberrations were measured while subjects monocularly viewed a monochromatic Maltese cross moving sinusoidally around 2D of accommodative demand with 1D amplitude at 0.2 Hz. The amplitude and phase (delay) of the accommodation response were compared to the actual vergence of the stimulus to obtain gain and temporal phase, calculated from wavefront aberrations recorded over time during experimental trials. The tested conditions were as follows: Correction of all the subject's aberrations except defocus (C); Correction of all the subject's aberratio…

AdultMaledirectional cuesgenetic structuresVisual AcuityRefraction Ocular01 natural sciencesdynamic accommodation010309 opticsYoung Adult03 medical and health sciences0302 clinical medicineOpticsmonochromatic aberrations0103 physical sciencesHumansWavefrontPhysicsdefocusbusiness.industryAccommodation OcularAstigmatismOriginal ArticlesConvergence Oculareye diseasesSensory SystemsOphthalmologySpherical aberrationAmplitude030221 ophthalmology & optometryFemaleOriginal Articlesense organsMonochromatic colorbusinessAccommodationPhotic StimulationOptometryOphthalmic and Physiological Optics
researchProduct

Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices.

2014

Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured…

InterferometriaAdultAnterior ChamberScheimpflug principlePhotography/methodsPupil diameterIrisPupila/fisiologiaDiagnostic Techniques OphthalmologicalAnterior chamber anglePupilYoung AdultOpticsAnterior chamber/pathologyImaging Three-Dimensionallcsh:OphthalmologymedicineDiagnostic techniques ophthalmologicalPhotographyHumansPentacam hrDioptrePhysicsWhite to whitemedicine.diagnostic_testbusiness.industryPupilGeneral MedicineTécnicas de diagnóstico oftalmológicoCorneal topographyeye diseasesOphthalmologyInterferometryCâmara anterior/patologialcsh:RE1-994Fotografia/métodosTopografia da córneasense organsCorneal topographyPupil/physiologybusinessNuclear medicineArquivos brasileiros de oftalmologia
researchProduct

Dynamic accommodation without feedback does not respond to isolated blur cues

2016

Highlights • A new methodology is used to study a potential cue for dynamic accommodation. • We show that human accommodation is not driven correctly by defocus alone. • Accommodation is most efficient using changes in stimulus vergence with feedback.

AdultMaleAccommodationmedicine.medical_specialtygenetic structuresComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONAudiologyStimulus (physiology)Article050105 experimental psychologyPupilDynamic accommodationYoung Adult03 medical and health sciences0302 clinical medicineOpticsVergencemedicineHumans0501 psychology and cognitive sciencesMaltese crossbusiness.industry05 social sciencesHealthy subjectsAccommodation OcularBiofeedback PsychologyRefractive ErrorsSensory SystemsOphthalmologyAberrations of the eyeSpherical aberration030221 ophthalmology & optometryFemalesense organsCuesbusinessPsychologyHigher-order aberrationsAccommodationVision Research
researchProduct

Effect of phenylephrine on static and dynamic accommodation

2018

Purpose We tested the hypothesis that changes in accommodation after instillation of Phenylephrine Hydrochloride (PHCl) observed in some studies could be caused by changes in optics. Methods We performed two experiments to test the effects of PHCl on static and on dynamic accommodation in 8 and 6 subjects, respectively. Objective wavefront measurements were recorded of the static accommodation response to a stimulus at different distances or dynamic accommodation response to a sinusoidally moving stimulus (between 1 and 3 D of accommodative demand at 0.2 Hz). The responses were characterized using two methods: one that takes into account the mydriatic optical effects on the accommodation pr…

AdultMaleOriginal articleAccommodationMydriaticsmedicine.medical_specialtygenetic structuresPhenylephrine03 medical and health sciences0302 clinical medicineCiliary bodyOphthalmologymedicineHumansAcomodaciónPhenylephrineMathematicsbusiness.industryCiliary BodyMétricaPupil sizeAccommodation OcularPhenylephrine Hydrochlorideeye diseasesCiliary musclemedicine.anatomical_structure030221 ophthalmology & optometryMetricsFemalesense organsbusinessFenilefrinaAccommodation030217 neurology & neurosurgeryOptometrymedicine.drugJournal of Optometry
researchProduct

Effect of even and odd-order aberrations on the accommodation response

2017

Aim To investigate the potential effect that odd and even-order monochromatic aberrations may have on the accommodation response of the human eye. Methods Eight healthy subjects with astigmatism below 1 D, best corrected visual acuity 20/20 or better and normal findings in an ophthalmic examination were enrolled. An adaptive optics system was used in order to measure the accommodation response of the subjects' eyes under different conditions: with the natural aberrations being present, and with the odd and even-order aberrations being corrected. Three measurements of accommodation response were monocularly acquired at accommodation demands ranging from 0 to 4 D (0.5 D step). Results The acc…

Ophthalmic examinationAstigmatism050105 experimental psychologyadaptive optics03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyClinical Researchmonochromatic aberrationsMedicine0501 psychology and cognitive sciences10. No inequalityAdaptive opticsaccommodation responseBest corrected visual acuitybusiness.industry05 social sciencesHealthy subjectsmedicine.disease960Ophthalmologymedicine.anatomical_structurelcsh:RE1-994030221 ophthalmology & optometryOptometryHuman eyeAccommodative lagbusinessAccommodationInternational Journal of Ophthalmology
researchProduct

Objective assessment of the effect of pupil size upon the power distribution of multifocal contact lenses

2017

AIM: To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses. METHODS: Two multifocal contact lenses of center-near design and one multifocal contact lens of center-distance design were used in this study. Their power profiles were measured using the NIMO TR1504 device (LAMBDA-X, Belgium). Based on their power profiles, the power distribution was assessed as a function of pupil size. For the high addition lenses, the resulting refractive power as a function of viewing distance (far, intermediate, and near) and pupil size was also analyzed. RESULTS: The power distribution of the lenses was affected by pupil siz…

Distribution (number theory)genetic structuresLentes de contactoOptical powerAstrophysics::Cosmology and Extragalactic Astrophysicslaw.inventionObjective assessment03 medical and health sciences0302 clinical medicineOpticsClinical ResearchlawMedicineComputer visionbusiness.industryPupil sizeeye diseasesPower (physics)Lens (optics)Contact lensOphthalmologyPupil magnification030221 ophthalmology & optometryOftalmologíaArtificial intelligencesense organsbusiness030217 neurology & neurosurgery
researchProduct

Optical quality of rotationally symmetrical contact lenses derived from their power profiles.

2017

To present a methodology for evaluating the optical quality of rotationally symmetrical contact lenses (CLs) from a single power profile.Simulated rotationally symmetrical power profiles corresponding to different CLs designs (monofocal, two-zone center-near bifocal, and four-zone center-distance bifocal) were used to calculate the wavefront error profile by means of numerical integration. Then, each lens wavefront error profile was spun around the center to obtain the lens wavefront error surface. From the surface, monochromatic optical transfer functions (OTF), simulated images and the visual Strehl ratio based on the OTF (VSOTF) were obtained for different distances and pupil sizes (3 an…

Optics and PhotonicsMaterials sciencebusiness.industryContact LensesPupilGeneral MedicineEquipment DesignPresbyopiaModels TheoreticalRefraction Ocular01 natural sciencesOptical qualityPower (physics)010309 opticsContact lens03 medical and health sciencesOphthalmology0302 clinical medicineOptics0103 physical sciences030221 ophthalmology & optometryHumansbusinessOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Temporal multiplexing with adaptive optics for simultaneous vision.

2016

We present and test a methodology for generating simultaneous vision with a deformable mirror that changed shape at 50 Hz between two vergences: 0 D (far vision) and −2.5 D (near vision). Different bifocal designs, including toric and combinations of spherical aberration, were simulated and assessed objectively. We found that typical corneal aberrations of a 60-year-old subject changes the shape of objective through-focus curves of a perfect bifocal lens. This methodology can be used to investigate subjective visual performance for different multifocal contact or intraocular lens designs.

Visual acuitygenetic structuresComputer scienceImage qualitymedicine.medical_treatmentIntraocular lensTemporal multiplexingDeformable mirrorArticlelaw.invention03 medical and health sciences0302 clinical medicineOpticslawmedicineComputer visionAdaptive opticsbusiness.industryAtomic and Molecular Physics and Opticseye diseasesLens (optics)Spherical aberration030221 ophthalmology & optometryArtificial intelligencesense organsmedicine.symptombusiness030217 neurology & neurosurgeryBiotechnologyBiomedical optics express
researchProduct

Assessing the in vitro optical quality of presbyopic solutions based on the axial modulation transfer function.

2016

Purpose To present a metric for assessing the in vitro optical quality of rotationally symmetrical optical elements based on volume calculation under the surface defined by the axial modulation transfer function (MTF). Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The metric volume under the axial MTF was used to assess the optical quality of 2 rotationally symmetrical multifocal intraocular lenses (IOLs) within various defocus intervals (0.50 diopter [D], 0.75 D, and 1.00 D) and at various spatial frequency intervals (7.5 cycles per degree [cpd], 15.0 cpd, and 30.0 cpd). Results The far focus of the bifocal IOL yielded higher volume values at all spati…

Optics and PhotonicsProsthesis Design01 natural sciences010309 optics03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularOptical transfer function0103 physical sciencesDioptreVision OcularMathematicsLenses Intraocularbusiness.industryMultifocal intraocular lensSensory SystemsOptical qualityOphthalmologySpainMetric (mathematics)030221 ophthalmology & optometrySurgeryObjective evaluationSpatial frequencybusinessFocus (optics)Journal of cataract and refractive surgery
researchProduct

Changes in the anterior chamber during accommodation assessed with a Scheimpflug system.

2014

Purpose To study changes in the anterior chamber depth (ACD), anterior chamber angle, and pupil diameter with accommodation. Setting University of Valencia, Valencia, Spain. Design Evaluation of diagnostic technology. Methods A rotating Scheimpflug camera (Pentacam HR) was used to measure changes in the ACD, anterior chamber angle, and pupil diameter with accommodation. Peripheral ACD was measured at the corneal center and 2.0 mm away from it in the nasal, superior, temporal, and inferior directions. The anterior chamber angle was computed as the mean anterior chamber angle of the entire eye. All measurements were obtained with accommodation stimuli ranging from +1.0 to −4.0 diopters (D) in…

AdultMalemedicine.medical_specialtyDesign evaluationAnterior ChamberScheimpflug principlePupil diameterDiagnostic Techniques OphthalmologicalAnterior chamber angleYoung AdultOphthalmologyDiagnostic technologymedicinePhotographyHumansPentacam hrDioptrebusiness.industryAccommodation OcularPupilSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsbusinessAccommodationJournal of cataract and refractive surgery
researchProduct

Tolerance to rotation of toric monofocal and bifocal intraocular lenses. A theoretical study

2018

Abstract This manuscript aims to evaluate the tolerance to rotation of a toric monofocal and a toric bifocal intraocular lenses with different cylinder powers. Theoretical designs based on wavefront aberrations were created to simulate a toric monofocal and a toric bifocal intraocular lens. Cylinder power ranged from −1 D to −6 D, in steps of −1 D. Tolerance to rotation was estimated by the visual Strehl ratio based on the optical transfer function (VSOTF) metric. Tolerance to rotation for both monofocal and bifocal intraocular lenses decreased when the cylinder power increased. For the bifocal design studied, the tolerance to rotation was larger for the near focus than for the far, however…

Wavefrontbusiness.industrymedicine.medical_treatmentStrehl ratioIntraocular lensRotation01 natural sciencesAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materials010309 optics03 medical and health sciences0302 clinical medicineOpticsIntraocular lensesOptical transfer function0103 physical sciences030221 ophthalmology & optometrymedicineCylinderElectrical and Electronic EngineeringFocus (optics)businessMathematicsOptik
researchProduct

Avaliação da resposta de acomodação após tarefas visuais próximas usando diferentes dispositivos eletrônicos portáteis

2015

ABSTRACT Purpose: To assess the accommodation response after short reading periods using a tablet and a smartphone as well as determine potential differences in the accommodation response at various stimulus vergences using a Hartmann- Shack aberrometer. Methods: Eighteen healthy subjects with astigmatism of less than 1 D, corrected visual acuity of 20/20 or better, and normal findings in an ophthalmic examination were enrolled. Accommodation responses were obtained under three different conditions: accommodation system of the eye relaxed and visually stressed with a tablet and an smartphone for 10 min, at a distance of 0.25 m from the subject's eyes. Three measurements of accommodation res…

AdultVisual acuityCorneal Wavefront AberrationSmartphone/utilizaçãogenetic structuresVisual AcuityComputadores de mão/utilizaçãoStimulus (physiology)Refraction Ocular01 natural sciencesNear visual acuity010309 optics03 medical and health sciences0302 clinical medicinelcsh:Ophthalmology0103 physical sciencesAberrometrymedicineHumansWavefrontbusiness.industryAberrometryComputadores/utilizaçãoGeneral MedicineAmplitude of accommodationOphthalmologySpherical aberrationAcomodação ocularlcsh:RE1-994Accommodation ocular030221 ophthalmology & optometryOptometrySmartphonemedicine.symptombusinessPsychologyAccommodationCell PhoneComputers handheld
researchProduct

Assessment of corneal thickness and tear meniscus during contact-lens wear

2014

To assess the effect of seven different daily disposable contact lenses upon corneal thickness, as well as upon tear meniscus volume, by using optical coherence tomography (OCT).Thirty-four young healthy subjects wore seven different types of daily disposable soft contact lenses, each for a period of 12h: Delefilcon A, Nelfilcon A, Omafilcon A, Filcon II3, Narafilcon A, Etafilcon A and Hilafilcon B. Central and mid-peripheral corneal thickness and lower tear meniscus volume (TMV) were measured using an OCT device during contact-lens wear at 4-h intervals throughout a 12-h period. Measurements were also recorded without any contact lenses being worn during a day.In the no-lens scenario a sma…

AdultMalemedicine.medical_specialtyMaterials sciencegenetic structuresSurface PropertiesCorneaYoung AdultOptical coherence tomographyOphthalmologyCorneaMyopiamedicineHumansmedicine.diagnostic_testHealthy subjectsGeneral MedicineContact Lenses Hydrophiliceye diseasesContact lensOphthalmologyTear meniscusmedicine.anatomical_structureTearsTearsFemaleDaily disposablesense organsTomography Optical CoherenceOptometryContact Lens and Anterior Eye
researchProduct

In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens.

2015

Purpose To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Finevision full diffractive trifocal IOL. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of lig…

Optics and PhotonicsOptical PhenomenaComputer sciencemedicine.medical_treatmentCataract ExtractionProsthesis DesignRefraction Ocular03 medical and health sciencesNear vision0302 clinical medicineLens Implantation IntraocularOptical transfer functionmedicineProsthesis designHumansLenses IntraocularStrehl ratioCataract surgeryMultifocal intraocular lensModels TheoreticalSensory SystemsOptical qualityOphthalmologyIntraocular lenses030221 ophthalmology & optometryOptometrySurgery030217 neurology & neurosurgeryJournal of cataract and refractive surgery
researchProduct

Effect of Phenylephrine on the Accommodative System

2016

Accommodation is controlled by the action of the ciliary muscle and mediated primarily by parasympathetic input through postganglionic fibers that originate from neurons in the ciliary and pterygopalatine ganglia. During accommodation the pupil constricts to increase the depth of focus of the eye and improve retinal image quality. Researchers have traditionally faced the challenge of measuring the accommodative properties of the eye through a small pupil and thus have relied on pharmacological agents to dilate the pupil. Achieving pupil dilation (mydriasis) without affecting the accommodative ability of the eye (cycloplegia) could be useful in many clinical and research contexts. Phenylephr…

genetic structuresArticle Subjectsense organseye diseasesJournal of Ophthalmology
researchProduct

Assessing the accommodation response after near visual tasks using different handheld electronic devices

2018

ABSTRACT Purpose: To assess the accommodation response after short reading periods using a tablet and a smartphone as well as determine potential differences in the accommodation response at various stimulus vergences using a Hartmann- Shack aberrometer. Methods: Eighteen healthy subjects with astigmatism of less than 1 D, corrected visual acuity of 20/20 or better, and normal findings in an ophthalmic examination were enrolled. Accommodation responses were obtained under three different conditions: accommodation system of the eye relaxed and visually stressed with a tablet and an smartphone for 10 min, at a distance of 0.25 m from the subject's eyes. Three measurements of accommodation res…

genetic structures
researchProduct