0000000001326669

AUTHOR

Manuel Núñez De Murga

showing 3 related works from this author

CASA-Mot technology: how results are affected by the frame rate and counting chamber.

2017

For over 30 years, CASA-Mot technology has been used for kinematic analysis of sperm motility in different mammalian species, but insufficient attention has been paid to the technical limitations of commercial computer-aided sperm analysis (CASA) systems. Counting chamber type and frame rate are two of the most important aspects to be taken into account. Counting chambers can be disposable or reusable, with different depths. In human semen analysis, reusable chambers with a depth of 10 µm are the most frequently used, whereas for most farm animal species it is more common to use disposable chambers with a depth of 20 µm . The frame rate was previously limited by the hardware, although chang…

MaleImage processingKinematicsReproductive technologyBiology03 medical and health sciences0302 clinical medicineEndocrinologySpecies SpecificityGeneticsImage Processing Computer-AssistedOptimal combinationAnimalsHumansAnimal speciesMolecular Biology030219 obstetrics & reproductive medicineSperm Count0402 animal and dairy science04 agricultural and veterinary sciencesFrame rate040201 dairy & animal scienceSpermatozoaSemen AnalysisReproductive MedicineSperm MotilityAnimal Science and ZoologyBiological systemSoftwareDevelopmental BiologyBiotechnologyReproduction, fertility, and development
researchProduct

Efecto de la cámara de recuento utilizada sobre los parámetros espermáticos, analizados con el ISASv1®

2012

Resumen Introduccion El uso de las camaras de recuento condiciona los valores de concentracion y movilidad espermatica debido a su tipo de carga (capilaridad o desplazamiento de la gota) y a la altura que presenten. Recientemente, se han introducido nuevas camaras, tanto desechables (ISAS ® D4C) como reusables (Spermtrack ® ) con diversas alturas en cada caso. Objetivo El objetivo del presente trabajo es validar su uso, analizando diversos parametros espermaticos con un sistema CASA, el ISASv1 ® . Material y metodo Se analizaron muestras de donantes voluntarios (10 para las desechables y 5 para las reusables), analizando el efecto del tipo de camara, de la altura, del tiempo de carga y del …

Reproductive MedicineUrologyRevista Internacional de Andrología
researchProduct

Introducción a la investigación biológica (2008/2009)

2008

Textos científicosCienciasRecursos informáticosTecnologías de la Información y la ComunicaciónUNESCO::MATEMÁTICAS::Ciencia de los ordenadoresInformación científicaFuentes bibliográficasOCWInglés científico
researchProduct