6533b7d3fe1ef96bd125fe03
RESEARCH PRODUCT
Performance study of the fast timing Cherenkov detector based on a microchannel plate PMT
Igor MorozovVladimir KaplinWladyslaw Henryk TrzaskaArtem KonevskikhDmitry FinogeevArseniy ShabanovV. GrigorievTatiana KaravichevaA. B. KurepinA. I. MayevskayaDmitry SerebryakovMaciej SlupeckiVitaly LoginovA. N. KurepinOleg KaravichevAnatoly TikhonovYu.a. Melikyansubject
PhysicsHistoryPhotomultiplierPhysics::Instrumentation and Detectors010308 nuclear & particles physicsbusiness.industryCherenkov detectorQuantitative Biology::Tissues and OrgansDetectorAstrophysics::Instrumentation and Methods for Astrophysics01 natural sciencesParticle detectorComputer Science ApplicationsEducationlaw.inventionOpticslaw0103 physical sciencesScintillation counterMeasuring instrumentMicrochannel plate detector010306 general physicsbusinessColliderdescription
Prototype of the fast timing Cherenkov detector, applicable in high-energy collider experiments, has been developed basing on the modified Planacon XP85012 MCP-PMT and fused silica radiators. We present the reasons and description of the MCP-PMT modification, timing and amplitude characteristics of the prototype including the summary of the detector's response on particle hits at oblique angles and MCP-PMT performance at high illumination rates.
year | journal | country | edition | language |
---|---|---|---|---|
2017-01-01 | Journal of Physics: Conference Series |