Anaphylaktoide Reaktion auf ein nichtionisches Röntgenkontrastmittel in Allgemeinanästhesie
Wangemann BDick WWisser GJ.-p. Jantzensubject
Tachycardiabusiness.industryGeneral MedicineCritical Care and Intensive Care MedicineIopamidolIsoflurane anaesthesiaBronchospasmContrast mediumAnesthesiology and Pain MedicineIsofluraneAnesthesiaEmergency MedicinemedicineGeneral anaesthesiaAnaphylactoid reactionsmedicine.symptombusinessmedicine.drugdescription
The occurrence of adverse reactions is decreasing since the introduction of non-ionic contrast media. Anaphylactoid reactions during general anaesthesia are rare and hitherto only documented with the administration of ionic compounds. We report an episode of hypotension, tachycardia, bronchospasm and urticaria following application of a non-ionic contrast medium (Iopamidol) during isoflurane anaesthesia. We conclude that a combinent use of anaesthesia and non-ionic contrast media does not guaranty protection from anaphylactoid reactions to iodinated radiopaque compounds.
year | journal | country | edition | language |
---|---|---|---|---|
1990-08-01 | AINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie |