6533b822fe1ef96bd127cf59
RESEARCH PRODUCT
Computational fluid dynamics in the assessment of patients' postoperative status after glottis-widening surgery
Krzysztof WarmuzińskiDaniel JaneckiMaciej MisiołekMagdalena MarkówBogusława Oreckasubject
MalePatient-Specific ModelingLarynxVital capacityVital CapacityVideo RecordingMedicine (miscellaneous)Peak Expiratory Flow RateVocal Cords02 engineering and technologyForced Expiratory VolumePharmacology (medical)LungGenetics (clinical)Aged 80 and overPressure dropair flowMiddle Agedrespiratory system021001 nanoscience & nanotechnologyBiomechanical PhenomenaTreatment Outcomemedicine.anatomical_structureVocal foldsBreathingFemaleRadiologyCFD0210 nano-technologyVocal Cord ParalysisGlottismedicine.medical_specialtyGlottis0206 medical engineeringAirflowGeneral Biochemistry Genetics and Molecular BiologyFEV1/FVC ratioPhonationImage Interpretation Computer-AssistedInternal MedicinemedicineHumansAgedbilateral vocal fold paralysisLaryngoscopybusiness.industry020601 biomedical engineeringSpirometryCase-Control StudiesReviews and References (medical)HydrodynamicsbusinessSoftwaredescription
Background. Computational fluid dynamics (CFD), a rapidly developing instrument with a number of practical applications, allows calculation and visualization of the changing parameters of airflow in the upper respiratory tract. Objectives. The aim of this study was to demonstrate the advantages of CFD as an instrument for noninvasive tests of the larynx in patients who had undergone surgical treatment due to bilateral vocal fold paralysis. Material and Methods. Surface measurements of the glottic space were made during maximum adduction of the vocal folds. Additionally, the following spirometric parameters were determined: forced vital capacity (FVC), forced expiratory volume in the first second (FEV1), and peak expiratory flow (PEF) rate. Based on the measurements, commercial mesh generation software was used to develop a geometrical model of the glottic space. The computations were carried out using a general purpose CFD code. The analysis included patients who were surgically treated for BVFP in the authors’ department between 1999 and 2012. The study group consisted of 22 women (91.67%) and 2 men (8.33%). Results. It was observed that the pressure drop calculated for free breathing depends on the area of the glottis and is independent of its shape. Importantly, for areas below approx. 40 mm2, a sudden rise occurred in the resistance to flow; for the smallest glottic areas studied, the pressure drop was almost 6 times higher than for an area of 40 mm2. Consequently, in cases of areas below 40 mm2 even minor enlargement of the glottic opening can lead to a marked improvement in breathing comfort. Conclusion. Computational fluid dynamics is a useful method for calculating and visualizing the changing parameters of airflow in the upper respiratory tract.
year | journal | country | edition | language |
---|---|---|---|---|
2017-09-29 | Advances in Clinical and Experimental Medicine |