6533b82cfe1ef96bd128ebd3
RESEARCH PRODUCT
The energy calibration of LEP in the 1993 scan
A. HofmannStephen MyersHelmut BurkhardtC. M. HawkesM. VadonL. RolandiH. WachsmuthGunter QuastJorg WenningerMichael KoratzinosG. J. BobbinkRob VeenhofR. G. JacobsenJ. GasconP. B. RentonT. R. WyattM. PlacidiJ BillanD. M. StromH. GroteD. E. PlaneA DreesK N HenrichsenR W AssmannJ.p. KoutchoukF. BordryA. BeuretE. PeschardtM. JonkerA. BlondelR. SchmidtBernd DehningR. BillenJ. MilesP. Grosse-wiesmannsubject
PhysicsSystematic errorNuclear physicsPhysics and Astronomy (miscellaneous)CalibrationPhysics::Accelerator PhysicsAccelerators and Storage RingsEngineering (miscellaneous)Beam energyEnergy (signal processing)Absolute calibrationdescription
This report summarizes the procedure for providing the absolute energy calibration of the LEP beams during the energy scan in 1993. The average beam energy around the LEP ring was measured in 25 calibrations with the resonant depolarization technique. The time variation of this average beam energy is well described by a model of the accelerator based on monitored quantities. The absolute calibration of the centre of mass energies of the off-peak points is determined with a precision of 2 parts in 10(5) resulting in a systematic error on the Z-mass of about 1.4 MeV and on the Z-width of about 1.5 MeV.
year | journal | country | edition | language |
---|---|---|---|---|
1995-12-01 | Zeitschrift für Physik C Particles and Fields |