6533b82dfe1ef96bd12920f8
RESEARCH PRODUCT
Determination of absolute internal conversion coefficients using the SAGE spectrometer
Juha SorriPaul GreenleesPhilippos PapadakisJoonas KonkiDaniel CoxKalle AuranenJari PartanenMikael SandzeliusJanne PakarinenPanu RahkilaJuha UusitaloR.-d. HerzbergJ. SmallcombeP.j. DaviesC.j. BartonD.g. Jenkinssubject
electron spectroscopyinternal conversion coefficientsilicon detectorbackground subtractionenergy reconstructiondescription
A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of 154Sm, 152Sm and 166Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given. peerReviewed
year | journal | country | edition | language |
---|---|---|---|---|
2016-01-01 |