6533b857fe1ef96bd12b4f0c

RESEARCH PRODUCT

Characterization process to measure the electrical contact resistance of Gas Diffusion Layers under mechanical static compressive loads

S. El OualidS. El OualidDenis CandussoDenis CandussoRémy LachatRémy LachatYann Meyer

subject

Materials scienceEnergy Engineering and Power TechnologyModulusElectric generatorProton exchange membrane fuel cell02 engineering and technologyPROPRIETE MECANIQUE7. Clean energylaw.inventionGenerator (circuit theory)GAS DIFFUSION LAYERCOMPRESSIVE LOADSStack (abstract data type)lawCAPTEUR ELECTRIQUE[SPI.MECA.MEMA]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanics of materials [physics.class-ph]0502 economics and businessGaseous diffusion050207 economicsComposite materialELECTRICAL CONTACT RESISTANCESPROTON EXCHANGE MEMBRANE FUEL CELLRenewable Energy Sustainability and the Environment05 social sciencesContact resistance[SPI.NRJ]Engineering Sciences [physics]/Electric power021001 nanoscience & nanotechnologyCondensed Matter PhysicsElectrical contactsFuel TechnologyGAZCONSOMMATION DE CARBURANT0210 nano-technologyMECHANICAL PROPERTIES[SPI.NRJ] Engineering Sciences [physics]/Electric power

description

AEM2016. International conference on Advanced Energy Materials, University of Surrey, Guildford, ROYAUME-UNI, 12-/09/2016 - 14/09/2016; Recent research has identified the mechanical properties of the fuel cell internal components (in particular, the Gas Diffusion Layers - GDLs) as key-parameters to obtain high final performances of the generator. The mechanical compression modulus of these components, the stability of their mechanical properties with respect to temperature and humidity, and their ability to interact with water have an impact on the electrical contact resistances in the stack and, by consequence, on the overall performance of the electric generator. Reducing the losses by contact resistance is an objective necessary to optimize the fuel cells in operation. The study of GDL electrical behavior under various internal operating conditions provides a suitable database to better understand their effects on the overall stack performance. This paper describes an experimental method for measuring the electrical contact resistance versus the static mechanical pressure applied to the GDLs. A nonlinear behavior of the electrical contact resistance versus the mechanical stress is observed. The PTFE and MPL additions modify the electrical contact resistance.

https://hal.science/hal-01670694