6533b859fe1ef96bd12b76bd
RESEARCH PRODUCT
Questionnaires and simulations to assess daylighting in Italian university classrooms for IEQ and energy issues
Federica CaffaroT. Dalla MoraMarco BeccaliMarina BonomoloV. R. M. Lo VersoVincenzo CostanzoLaura BelliaF. BasileFrancesca FragliassoF. GiulianiFrancesco NoceraFabio Peronsubject
Equivalent melanopic luxSample (statistics)DAYKE-Italy; DAYKE project; questionnaire survey; daylight in classrooms; daylight metrics; equivalent melanopic lux; statistical analyses.DAYKE-ItalyQuestionnaire surveyDaylight metricStatistical analysesStatisticsDaylightElectrical and Electronic EngineeringDaylight illuminanceCivil and Structural EngineeringMathematicsSettore ING-IND/11 - Fisica Tecnica AmbientaleDaylight in classroomMechanical EngineeringDAYKE-Italy; Questionnaire survey; Daylight in classrooms; Daylight metrics; Equivalent melanopic lux; Statistical analysesQuestionnaireBuilding and ConstructionDaylight metricsCombined approachStatistical analysesDAYKE-Italy; DAYKE project; Questionnaire survey; Daylight in classrooms; Daylight metrics; Equivalent melanopic lux; Statistical analysesDaylight factorDAYKE projectDaylight in classroomsDaylightingdescription
Abstract Results from the DAYKE-Italy project are presented. An investigation on daylighting in eight classrooms in five Italian universities was carried out through a combined approach: an ad-hoc survey administered to students to investigate how they perceive daylight in classroom, and numerical simulations (DIVA + ALFA) to calculate a set of objective metrics (daylight, circadian, and energy-related). A sample of 542 questionnaires was collected through two sessions and the subjective judgments were correlated to objective metrics. Results from descriptive and statistical analyses showed: (i) the correlation was significant for all daylight metrics: among them, average daylight factor and annual light exposure performed higher correlations compared to daylight autonomy, spatial daylight autonomy and useful daylight illuminance; (ii) rooms with a scarce or an optimal daylight provision (according to standards) were rated with comparable subjective score; (iii) the equivalent melanopic lux showed a higher correlation than daylight metrics based on the horizontal workplane; (iv) energy saving up to 50% can be achieved in the presence of high daylight provision and through daylight responsive controls; however, a relamping of fluorescent systems with LED system is recommended to optimize the consumption; furthermore, estimated saving correlated significantly with objective metrics.
year | journal | country | edition | language |
---|---|---|---|---|
2021-12-01 |