6533b85dfe1ef96bd12bea33

RESEARCH PRODUCT

Experimental comparison of two control algorithms for low-saliency ratio interior permanent magnet synchronous motors

A. O. Di TommasoCiro SpataroMassimo CarusoM. LombardoRosario MiceliC. Nevoloso

subject

010302 applied physicsRapid prototypingControl algorithmElectromagneticsPermanent magnet synchronous motorComputer scienceRenewable Energy Sustainability and the Environment020208 electrical & electronic engineeringlow saliency ratio motor02 engineering and technologySettore ING-IND/32 - Convertitori Macchine E Azionamenti Elettrici01 natural sciencesField oriented control algorithmmaximum torque per ampere control algorithmControl theoryMagnet0103 physical sciencesAutomotive Engineering0202 electrical engineering electronic engineering information engineeringTorqueInterior permanent magnet synchronous machineAmpereMaximum torque

description

In this paper, an experimental investigation on the comparison between the Maximum Torque Per Ampere (MTPA) and the Field Orientation Control (FOC) algorithms for interior permanent magnet synchronous machines (IPMSMs) is described, analyzed and discussed. This investigation was carried out on a small-power IPMSM with low saliency ratio. More in detail, after a previous simulation study, the control techniques have been experimentally implemented and validated through means of a dSPACE® rapid prototyping system. The performances of the two algorithms have been evaluated and compared, obtaining interesting results.

10.1109/ever.2018.8362345http://hdl.handle.net/10447/293491