6533b85dfe1ef96bd12bf16d
RESEARCH PRODUCT
Coherence loss in phase-referenced VLBI observations (Corrigendum)
Eduardo RosEduardo RosS. Jiménez-monferrerJ. C. GuiradoJ. M. MarcaideMiguel A. Pérez-torresIvan Marti-vidalsubject
PhysicsClassical mechanicsSpace and Planetary ScienceQuantum mechanicsVery-long-baseline interferometryPhase (waves)Astronomy and AstrophysicsAstrophysicsConstant (mathematics)Value (mathematics)Coherence (physics)description
fat = K ν √ Δt sin θ, (2) where K ∼ 0.012 h0.5 GHz−1. This new equation implies a different value of the constant k1 in Eq. (4). The original value reported for k1 was ∼63, while the correct value is ∼1.3 × 104. Although Eq. (3) (together with the constants K and k1) was incorrectly written in the text, we emphasize that all the figures in the paper were generated, indeed, using the correct equations and constants.
year | journal | country | edition | language |
---|---|---|---|---|
2011-09-01 | Astronomy & Astrophysics |