Abstract The TRIGA Mark II reactor at the University of Mainz provides ideal conditions for duplicating BNCT treatment as performed in Pavia, Italy, in 2001 and 2003 [Pinelli, T., Zonta, A., Altieri, S., Barni, S., Braghieri, A., Pedroni, P., Bruschi, P., Chiari, P., Ferrari, C., Fossati, F., Nano, R., Ngnitejeu Tata, S., Prati, U., Ricevuti, G., Roveda, L., Zonta, C., 2002. TAOrMINA: from the first idea to the application to the human liver. In: Sauerwein et al. (Eds.), Research and Development in Neutron Capture Therapy. Proceedings of the 10th International Congress on Neutron Capture Therapy, Monduzzi editore, Bologna, pp. 1065–1072]. In order to determine the optimal parameters for the planned therapy and therefore for the design of the thermal column, calculations were conducted using the MCNP-code and the transport code ATTILA. The results of the parameter study as well as a possible configuration for the irradiation of the liver are presented.
year | journal | country | edition | language |
---|---|---|---|---|
2009-07-01 | Applied Radiation and Isotopes |