6533b862fe1ef96bd12c7489
RESEARCH PRODUCT
Phosphatidylcholine-Gramicidin a Interaction Study in Non-Aqueous Solvent with a new HPLC-SEC Column
Concepción AbadLorenzo Bracosubject
Solventchemistry.chemical_compoundAqueous solutionChromatographyColumn chromatographyResolution (mass spectrometry)chemistryPhosphatidylcholineMolecular Medicinelipids (amino acids peptides and proteins)Biological membraneHigh-performance liquid chromatographyTetrahydrofurandescription
Abstract A new HPLC-SEC column, Ultrastyragel 500 A, has been assayed in order to check the separation between gramicidin A and phosphatidylcholine in tetrahydrofuran. The good resolution of both compounds has allowed the quantitation of lipid-polypeptide interaction in terms of the binding ratio parameter, BR. A BR value of 3.6 moles of phosphatidylcholine per mole of gramicidin A has been obtained for a 0.1 % (w/v) phosphatidylcholine solution as eluent. The suitability of this support for studies on lipid-polypeptide interactions in non-aqueous solvents is demonstrated.
year | journal | country | edition | language |
---|---|---|---|---|
1985-03-01 | Journal of Liquid Chromatography |