Search results for " Abutment"

showing 6 items of 46 documents

Culturomic and quantitative real‐time ‐ polymerase chain reaction analyses for early contamination of abutments with different surfaces: A randomized…

2021

Background Rough and/or plasma-activated abutments seem to be able to increase soft tissue adhesion and stability; however, limited evidence is available about bacterial contamination differences. Purpose The aim was to investigate the oral microbiota on four dental abutments with different surfaces by quantitative real-time polymerase chain reaction (qRT-PCR) and culturomic approach. Methods Forty patients needing a single implant rehabilitation were involved in the study. Forty healing abutments, especially designed for the study, were divided into four groups according to the surface topography (1. machined [MAC], 2. machined plasma of argon treated [plasmaMAC], 3. ultrathin threaded mic…

TitaniumDental ImplantsSurface Propertiesbusiness.industrySoft tissueDentistryContaminationoral microbiotaReal-Time Polymerase Chain Reactionlaw.inventionSettore MED/28 - MALATTIE ODONTOSTOMATOLOGICHEOral Microbiotadental abutmentsRandomized controlled trialDental AbutmentslawHumansMedicineCotton swabImplantOral SurgeryQuantitative Real-Time Polymerase Chain ReactionbusinessGeneral DentistryRCTClinical Implant Dentistry and Related Research
researchProduct

Soft tissue integration of different abutment surfaces: An experimental study with histological analysis

2021

OBJECTIVE To evaluate whether abutment surface and surface bio-activation have an effect on soft tissue morphogenesis. MATERIALS AND METHODS 36 patients (36 implants) were included. Abutments were randomly divided into 4 groups (n = 9): Smooth Surface-MAChined (MAC), Ultrathin Threaded Microsurface (UTM), MAC Plasma of Argon activated (Plasma-MAC), and UTM Plasma of Argon activated (Plasma-UTM). After 2 months of healing, soft tissue samples were collected and prepared for histological analysis. The margin of the peri-implant mucosa (PM), the apical extension of the barrier epithelium (aJE), and the apical location of the abutment (AM) were identified. Significances of differences among gro…

abutment0206 medical engineeringAbutmentConnective tissueDentistryPlasma treatmentDental Abutments02 engineering and technologyperi-implant attachmentsoft tissue adaptation03 medical and health sciences0302 clinical medicinebiologic widthmedicineHumansArgonDental ImplantsTitaniumbusiness.industryChemistryDental Implantation EndosseousSoft tissue030206 dentistry020601 biomedical engineeringEpitheliumddc:617.6Dental Implantationmedicine.anatomical_structureConnective Tissuetransmucosal collarOral Surgeryabutment; biologic width; peri-implant attachment; soft tissue adaptation; transmucosal collarbusinessEndosseousTooth
researchProduct

Preliminary study about the efficiency of diode laser compared with retraction cords used for exposing the finishing lines of dental abutments before…

2016

diode laser retraction cords dental abutments optic impression
researchProduct

Is the re-use of sterilized implant abutments safe enough? (Implant abutment safety)

2019

Background: The reuse of implant healing abutments is common in dental practice. Effective elimination of bacteria and viruses is accomplished by conventional sterilization. The aim of this work was to explore the eventual survival of microorganisms on sterilized healing abutments and to rule out the presence of transmissible organic material after standard procedures. Material and Methods: A total of 55 healing abutments previously used in patients will be washed and sterilized in a steam autoclave at 121oC for 15 min. Each healing abutment will be cultured in Brain Heart Infusion broth (BHI) under strict aseptic conditions. Besides, two control groups will be included: one of 3 unused hea…

food.ingredientSurface PropertiesAbutmentDentistryDental AbutmentsAgar plateBioburden03 medical and health sciences0302 clinical medicinefoodDental AbutmentsHumansMedicineAgarGeneral DentistryDental ImplantsTitaniumOral Medicine and PathologyImplants dentalsbusiness.industryResearchDental implantsSterilization030206 dentistrySterilization (microbiology):CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologyUNESCO::CIENCIAS MÉDICASEsterilitzacióSurgeryAseptic processingImplantbusinessMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Definitive Abutments Placed at Implant Insertion and Never Removed: Is It an Effective Approach? A Systematic Review and Meta-Analysis of Randomized …

2017

Purpose To assess whether repeated abutment disconnections and reconnections have any impact on peri-implant bone resorption and soft tissue healing. Materials and Methods Electronic and manual searches were conducted for English-language articles published up to March 2017 that identified a relation between repeated disconnections of implant abutments (PA group) and prosthetic or implant failures, complications, marginal bone loss (MBL), soft tissue healing, and esthetic evaluation (pink esthetic score [PES]) after at least 1 year of function compared with implants receiving a final abutment at the time of implant placement (DA group). Results Fourteen articles (535 patients with 994 impla…

medicine.medical_specialtyAbutmentDentistryDental Abutmentslaw.invention03 medical and health sciences0302 clinical medicineDental AbutmentsRandomized controlled triallaw0502 economics and businessmedicineHumansDental Restoration FailureBone ResorptionDental ImplantsWound Healingbusiness.industry05 social sciencesSoft tissueDental Implant-Abutment Design030206 dentistryBuccal administrationSurgeryDental Implant-Abutment DesignOtorhinolaryngologyMeta-analysis050211 marketingSurgeryImplantOral SurgerybusinessJournal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons
researchProduct

Microbial Leakage at the Implant-Abutment Connection Due to Implant Insertion Maneuvers: Cross-Sectional Study 5 Years Postloading in Healthy Patient…

2015

The aim of this study was to test if stress on the prosthetic connection during insertion maneuvers can induce micro-warping at the implant connection. From September 2011 to July 2013, patients with implants loaded for at least 5 years that were placed with 2 different insertion implant mounters—MP (conventional) and ME (mountless)—were selected from all of those who had received dental implant therapy in the past and were attending routine check-up or spontaneous visits during the study period. Samples were obtained from inside the connection and the abutment surface using absorbent sterile paper tips. Quantitative real-time polymerase chain reaction was performed for total bacterial coun…

medicine.medical_treatmentDentistryEikenella corrodensTitanium abutmentCimplant-prosthetic prognosisAggregatibacter actinomycetemcomitansPrevotella intermediaImplant connection deformationBiomechanics; Cimplant-prosthetic prognosis; Implant connection deformation; Titanium abutmentMedicineHumansBiomechanicsDental implantRetrospective StudiesDental Implantsbiologybusiness.industryPrevotella intermediaAggregatibacter actinomycetemcomitansCampylobacter rectusTreponema denticolabiology.organism_classificationCross-Sectional StudiesImplantOral SurgeryFusobacterium nucleatumbusinessPorphyromonas gingivalisTreponema denticolaThe Journal of oral implantology
researchProduct