Search results for " Ala"
showing 10 items of 239 documents
Phylogenetic relationship of the green alga Nanochlorum eukaryotum deduced from its chloroplast rRNA sequences.
1995
The marine green coccoidal alga Nanochlorum eukaryotum (N.e.) is of small size with an average diameter of 1.5 microns. It is characterized by primitive-appearing biochemical and morphological properties, which are considerably different from those of other green algae. Thus, it has been proposed that N.e. may be an early developed algal form. To prove this hypothesis, DNA of N.e. was isolated by a phenol extraction procedure, and the chloroplast DNA separated by preparative CsCl density-gradient centrifugation. The kinetic complexity of the nuclear and of the chloroplast DNA was evaluated by reassociation kinetics to 3 x 10(7) bp and 9 x 10(4) bp, respectively. Several chloroplast genes, i…
Isolation and identification of new anthraquinones from Rhamnus alaternus L and evaluation of their free radical scavenging activity
2018
From the butanolic and the ethyl acetate extracts of Rhamnus alaternus L root bark and leaves, three new anthraquinone glycosides, alaternosides A-C (1,4,6,8 tetrahydroxy-3 methyl anthraquinone 1-O-ß-D-glucopyranosyl-4,6-di-O-α-L-rhamnopyranoside (1); 1,2,6,8 tetrahydroxy-3 methyl anthraquinone 8-O-ß-D-glucopyranoside (2) and 1, 6 dihydroxy-3 methyl 6 [2′-Me (heptoxy)] anthraquinone (3)) were isolated and elucidated together with the two known anthraquinone glycosides, Physcion-8-O-rutinoside (4) and emodin-6-O-α-L-rhamnoside (5) as well as with the known kaempferol-7-methylether (6), β-sitosterol (7) and β-sitosterol-3-O-glycoside (8). Their chemical structures were elucidated using spectr…
Zvaigžņotā Debess: 2011, Vasara (212)
2011
Contents: “ZVAIGŽŅOTĀ DEBESS” FORTY YEARS AGO: A.Balklavs. Extremely Distant New Objects of Metagalaxy (abridged) ; Newspaper „Literaturnaja Rossija” 9 April 1971. Astronautics: Yesterday, Today, Tomorrow (abridged) ; CONFERENCE “The VIEW from SPACE. FIRST MANNED SPACE FLIGHT – 50”: M.Gills. Conference on the Eve of Human Space Flight Anniversary ; J.Ekmanis, S.Negrejeva. Mstislav Keldysh and Golden Age of Soviet Science ; T.Millers. Contribution of Scientists of the Institute of Inorganic Chemistry to the Development of Space Technologies and Materials ; G.Vilka. Remembrance of Friedrich Zander in Rīga ; O.Plepis. My Contribution to the Development of Space Medicine ; J.Stradiņš. Latvia’s …
EXPOSURE OF Gd2O3-ALANINE AND Gd2O3-AMMONIUM TARTRATE ESR DOSIMETERS TO THERMAL NEUTRONS: EXPERIMENTS AND MONTE CARLO SIMULATIONS
2008
Electron Spin Resonance (ESR) dosimetry for clinical radiation beams.
2016
In the last two decades the electron spin resonance (ESR) technique has been widely adopted for dosimetry of the radiation beams used in radiation therapy. In particular, alanine dosimtery is nowadays recognized as an international standard system for transfer dosimetry and for high doses. This is because among the various solid-state dosimeters the alanine ESR detectors present several advantages such as: tissue equivalence, linearity of its dose-response over a wide range, high stability of radiation induced free radicals, no destructive read-out procedure, no sample treatment before EPR signal measurement. In this presentation the main applications of ESR dosimetry for the characterizati…
ESR response of alanine films exposed to low-energy (1-40 keV) X-rays
2018
Introduction L-a-alanine has aroused considerable interest for use in radiation ESR dosimetry. In this work, we examined the energy response of alanine ESR films in the low energy X-photon energy range between 1 keV and 40 keV. Dose measurements through a reference ionization chamber and a semiconductor detection system were also performed to complement ESR measurements. Methods Commercial alanine ESR films were used. All ESR signal measurements were also done using an XBand (9.7 GHz) Bruker spectrometer. The dosimeters were irradiated at the "Livio Scarsi" Laboratory (LAX) of the University of Palermo, where X-ray beams in the 1–40 keV energy range are produced using a Seifert SN60 tube. R…
A new association of relict maquis with Ptilostemon greuteri (Oleo-Ceratonion, Quercetea ilicis), located in a circumscribed area of north-western Si…
2022
This paper illustrates the results of a survey aimed at deepening available knowledge on the ecology of Ptilostemon greuteri (Asteraceae), a very rare palaeoendemic and relict nano-phanerophyte discovered about 15 years ago on Monte Inici, near Castellammare del Golfo (province of Trapani, north-western Sicily). Two plant communities characterised by P. greuteri are described in detail; they occur in the locus classicus and in a second, recently discovered stand, which is also very localised and threatened by fire. The field investigations revealed that the sites where the species grows are very similar from the ecological point of view; in fact, both of them are located on the steep slopes…
Kuinka mitata yliopiston vuorovaikutusta, vaikuttavuutta ja kolmatta tehtävää?
2023
Käsittelemme tässä artikkelissa yhteiskunnallista vuorovaikutusta ja sen mittaamiseen liittyviä haasteita erityisesti humanistis-yhteiskuntatieteellisellä kentällä. nonPeerReviewed
A robust calibration methodology for an On-Board Diagnostic car system
2006
New car models are now by law equipped with on-board diagnostic (OBD) systems aimed at monitoring the state of health of strategic components that ensure low levels of polluting exhaust emissions. During development phases, for each new car model, the OBD system must be finely calibrated. This article presents a robust calibration methodology taking into account sources of variability mainly due to production process, operating, and environmental conditions. The methodology enables us to evaluate the false alarm and failure to detect risks intrinsically related to the adopted calibration. An application concerning an upstream oxygen sensor monitored by the OBD is presented.
Radio measurements on a customized software defined radio module: A case study of energy detection spectrum sensing
2017
In this paper, we developed a software defined radio (SDR) system for implementing energy detection spectrum sensing. The SDR module can be used for a wide range of applications. The use of the SDR module is motivated by its high interoperability, availability for relatively cheaper prices and being software independent. Energy detection for cognitive radios is chosen for its simplicity and popularity. However, it is chosen as a representative for a very wide range of measurements and algorithms that can be implemented in the SDR. We have used probabilities of detection and false alarm with the receiver operating characteristics (ROC) curves as performance metrics for the implemented energy…