Search results for " Aneurysm"

showing 10 items of 380 documents

Letter to the Editor Regarding “Small Aneurysms with Low PHASES Scores Account for a Majority of Subarachnoid Hemorrhage Cases”

2020

medicine.medical_specialtySubarachnoid hemorrhageLetter to the editorbusiness.industryGeneral surgeryIntracranial AneurysmAneurysm RupturedSubarachnoid Hemorrhagemedicine.diseasemedicineHumansSurgeryNeurology (clinical)businessHumanWorld Neurosurgery
researchProduct

2021

Objective: Unruptured Intracranial Aneurysm (UIA) Treatment Score (UIATS) and PHASES score are used to inform treatment decision making for UIAs (treatment or observation). We assessed the ability of the scoring systems to discriminate between ruptured aneurysms and UIAs in a subarachnoid hemorrhage (SAH) cohort with multiple aneurysms.Methods: We retrospectively applied PHASES and UIATS scoring to the aneurysms of 40 consecutive patients with SAH and multiple intracranial aneurysms.Results: PHASES score discriminated better between ruptured aneurysms and UIAs than UIATS. PHASES scores and the difference between the UIATS subscores were higher for ruptured aneurysms compared with UIAs, whic…

medicine.medical_specialtySubarachnoid hemorrhageRuptured aneurysmsbusiness.industrymedicine.diseaseSurgeryDiscriminatory powerAneurysmNeurologyAneurysm treatmentCohortmedicineRupture riskcardiovascular diseasesNeurology (clinical)Multiple aneurysmsbusinessFrontiers in Neurology
researchProduct

Choice of the operative approach in two cardiosurgical patients assisted by preoperative computed tomography: Case Report

1988

The perioperative course of two patients is exemplified to demonstrate the significance of the preoperative thoracic computed tomography for the selection of a proper surgical approach.

medicine.medical_specialtySurgical approachmedicine.diagnostic_testThoracic computed tomographybusiness.industryComputed tomographyPerioperativeMiddle AgedAortic AneurysmCardiac surgerySurgeryThoracotomyPreoperative CareMyocardial RevascularizationmedicineHumansFemaleRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessAortaScandinavian Journal of Thoracic and Cardiovascular Surgery
researchProduct

Acute aortic dissection

2011

An acute aortic syndrome with simultaneous presence of a penetrating aortic ulcer, an intramural haematoma, a thoracic aortic dissection and an abdominal aortic aneurysm rupture has not previously been reported. Herein, we describe our experience with a patient treated by endovascular means with an 8-year follow-up.

medicine.medical_specialtyTime FactorsAortic RuptureAortic Diseases610 Medicine & healthAortographySettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationInternal medicinemedicineHumanscardiovascular diseasesAortic ruptureUlcerAged 80 and overAcute aortic syndromeAortic dissectionHematomaAortic Aneurysm Thoracic10042 Clinic for Diagnostic and Interventional Radiologybusiness.industryEndovascular ProceduresSyndromeGeneral Medicinemedicine.diseaseAbdominal aortic aneurysm10020 Clinic for Cardiac SurgerySurgeryIntramural haematomaAortic DissectionTreatment Outcomeacute aortic dissection syndromeAcute Diseasecardiovascular systemCardiologyThoracic aortic dissectionFemaleTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessAortic Aneurysm AbdominalJournal of Cardiovascular Medicine
researchProduct

Systemic pulsatile pressure in type II endoleaks after stent grafting of experimental abdominal aortic aneurysms.

2003

Purpose: To investigate pressure and maximum rate of rise of systolic pressure (peak dP/dt) in completely excluded aneurysms and endoleaks to determine the hemodynamic impact of endoleaks. Methods: In mongrel dogs (n = 36) experimental aneurysms were created by insertion of a patch (portion of rectus abdominis muscle sheath) into the infrarenal aorta. In group I (n = 18), all aortic branches of the aneurysm were ligated and all aneurysms were completely excluded by stent grafts. Group II (n = 18) consisted of aneurysms with patent aortic side branches that represented sources of endoleaks. One week (n = 12), six weeks (n = 12), and six months (n = 12) after stent grafting, hemodynamic measu…

medicine.medical_specialtyTime FactorsSystolemedicine.medical_treatmentDiastolePulsatile flowHemodynamicsCollateral CirculationBlood PressureAortic aneurysmBlood Vessel Prosthesis ImplantationAneurysmDogsPostoperative ComplicationsDiastoleInternal medicinemedicine.arteryMedicineAnimalsRadiology Nuclear Medicine and imagingAorta AbdominalAortabusiness.industryModels CardiovascularStentmedicine.diseaseDisease Models AnimalBlood pressurePulsatile Flowcardiovascular systemCardiologyStentsCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedAortic Aneurysm AbdominalFollow-Up StudiesCardiovascular and interventional radiology
researchProduct

Successful transcatheter aortic valve-in-valve implantation in a patient having a chronic type A aortic dissection

2017

medicine.medical_specialtyTranscatheter aortic030204 cardiovascular system & hematologyTranscatheter Aortic Valve Replacement03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineInternal medicineHumansMedicineAgedAortic dissectionAortic Aneurysm Thoracicbusiness.industryAngiographyAortic Valve Stenosis030229 sport sciencesmedicine.diseaseEchocardiography DopplerValve in valveAortic ValveHeart Valve ProsthesisChronic DiseaseCardiologyFemaleTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessEuropean Heart Journal
researchProduct

Implant-specific follow-up imaging of treated intracranial aneurysms: TOF-MRA vs. metal artifact reduced intravenous flat panel computed tomography a…

2017

Aim To compare the diagnostic quality of time-of-flight magnetic resonance angiography (TOF-MRA) and metal-artefact-reduction (MAR) flat-panel-detector computed tomography angiography (FPCTA) and to determine the imaging technique best suited for evaluation endovascular and surgically treated aneurysms. Methods The image quality of TOF-MRA and MAR-FPCTA of 44 intracranial implants (coiling: n= 20; clipping: n= 15; coiling + stenting: n= 9) in a patient cohort of 25 was evaluated by two independent readers. Images obtained using MAR-FPCTA (20 second scan time, 496 projections, intravenous contrast medium administration; Artis Zee, Siemens Healthcare, Forchheim) were compared with TOF-MRA-ima…

medicine.medical_specialtyWilcoxon signed-rank testImage qualityComputed Tomography Angiographymedicine.medical_treatmentContrast MediaMagnetic resonance angiography030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineAneurysmMcNemar's testmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesComputed tomography angiographyRetrospective Studiesmedicine.diagnostic_testbusiness.industryIntracranial AneurysmGeneral MedicineClipping (medicine)Prostheses and Implantsmedicine.diseaseImage EnhancementSurgical InstrumentsCerebral AngiographyMetalscardiovascular systemStentsImplantRadiologybusinessArtifacts030217 neurology & neurosurgeryMagnetic Resonance AngiographyFollow-Up StudiesClinical radiology
researchProduct

Tomographic left ventricular volume determination in the presence of aneurysm by three-dimensional echocardiographic imaging. I: Asymmetric model hea…

1996

To improve the accuracy of measurements of left ventricular volume in the presence of an aneurysm, we used three-dimensional echocardiographic imaging to analyze the shape of left ventricles in 23 asymmetric model hearts with eccentric aneurysms of different sizes, shapes, and localizations. A standard 3.75 MHz ultrasound probe with a rotation motor device was used to obtain a three-dimensional data set. By rotating the probe stepwise 1 degree, 180 radial ultrasound pictures were digitized. On the basis of the three-dimensional data set, the following parameters were determined and compared with the dimensions of the model hearts obtained by direct measurement: total left ventricular volume…

medicine.medical_specialtybusiness.industryCardiac VolumeHeart VentriclesUltrasoundEchocardiography Three-DimensionalModels CardiovascularLeft Ventriclesmedicine.diseaseBiplaneAneurysmStandard errorUltrasound probeEchocardiographyLinear regressionmedicineHumansVentricular volumeRadiology Nuclear Medicine and imagingRadiologyHeart AneurysmCardiology and Cardiovascular MedicineNuclear medicinebusinessMathematicsJournal of the American Society of Echocardiography
researchProduct

Take the wind out your salis: relationship among energy drink abuse, hypertension, and break-up of cerebral aneurysm

2011

medicine.medical_specialtybusiness.industryEnergy (esotericism)General surgeryenergy drink abuse hypertension cerebral aneurysmMEDLINEmedicine.diseaseSurgeryAneurysmHypertension complicationsEmergency MedicineInternal Medicinemedicinebusiness
researchProduct

CRT-723 Is the Sporadic Thoracic Aortic Aneurysm the Result of an Inflammatory Process?

2014

Sporadic thoracic aortic aneurysm (S-TAA) is potentially devastating with severe morbidity and mortality. The histopathologic underlying abnormality of both ascending aortic aneurysm and dissection is medial degeneration, a pathological entity initially described as no inflammatory lesions of smooth

medicine.medical_specialtybusiness.industryMedial degenerationSettore MED/23 - Chirurgia CardiacaDissection (medical)medicine.diseaseThoracic aortic aneurysmmetalloproteinasesAortic aneurysmcardiovascular systemmedicineAscending aorta aneurysm metalloproteinases angiotensin converting enzymeSevere morbiditycardiovascular diseasesRadiologyAbnormalityCardiology and Cardiovascular MedicinebusinessPathologicalProcess (anatomy)Ascending aorta aneurysmangiotensin converting enzymeJACC: Cardiovascular Interventions
researchProduct