Diagnostic radiological examinations and risk of intracranial tumours in adults—findings from the Interphone Study
2021
Abstract Background Exposure to high doses of ionizing radiation is among the few well-established brain tumour risk factors. We used data from the Interphone study to evaluate the effects of exposure to low-dose radiation from diagnostic radiological examinations on glioma, meningioma and acoustic neuroma risk. Methods Brain tumour cases (2644 gliomas, 2236 meningiomas, 1083 neuromas) diagnosed in 2000–02 were identified through hospitals in 13 countries, and 6068 controls (population-based controls in most centres) were included in the analysis. Participation across all centres was 64% for glioma cases, 78% for meningioma cases, 82% for acoustic neuroma cases and 53% for controls. Informa…
Abdominal Computed Tomography Angiography at 80kV: feasibility study.
2014
preliminary evaluation of different dose reduction algorithms in abdominal Computed Tomography Angiography (CTA) with standard scan protocols at 120kV vs. 80kV.prospective, randomized, crossover study. 60 consecutive patients who underwent CTA of the abdomen (Sensation 64, Siemens; Iomeprol 400 mgl/ml Bracco) for suspected or diagnosed Abdominal Aortic Aneurysm (AAA) were enrolled in the study. A standard 120kV/200mAs scan protocol was acquired in all patients (reference tube current modulated with Automatic Exposure Control). In each patient a second scan with 80kV/300mAs (Group 1; n. 20), 80kV/400mAs (Group 2; n. 20), 80kV/500mAs (Group 3; n. 20) was acquired. We used the same scan/recons…
A rare case of Prinzmetal angina 3 days after coronary artery stenting with a second-generation drug-eluting stent
2015
Non previsto.
MR-Angiographie peripherer Gefäße mit automatischer Verschiebetisch-Technik bei 1.0 T im Vergleich zur i. a. DSA
1999
PURPOSE Contrast-enhanced (CE) 3D-MR angiography of peripheral arteries was performed in 8 patients with peripheral arterial occlusive disease by applying a new tracking technique on a 1.0 T system (Magnetom Harmony, Siemens). The studies were compared with intra-arterial digital angiography as gold standard. MATERIALS AND METHODS Imaging of the distal aorta, pelvis, upper and lower limb arteries was accomplished with a Flash-3D-sequence (TR/TE = 6.2/3.2 ms) within 26 s acquisition time of each region after a single bolus of 30 ml contrast agent. Individual circulation time was determined by a test bolus before each examination. RESULTS 112 vessel segments were evaluated. MR angiography ach…
Kontrastverstärkte MR-Angiographie abdomineller Gefäßean einem 1.0 T-System*
2000
Purpose To evaluate the efficacy of breath-hold, three-dimensional, contrast-enhanced magnetic resonance angiography with a 1.0 T system for imaging the abdominal vessels in comparison to conventional arteriography (CA). Methods The abdominal aorta and visceral arteries were studied in 54 patients (60 examinations) on a 1.0 T scanner using an ultrafast gadolinium-enhanced gradient-echo sequence with the following parameters: TR/TE = 3.8/1.4 ms, flip angel 25 degrees, matrix 198 x 256, field 380-420 mm, pixel size 1.9 x 1.48 mm2, slice thickness 1.5-2.5 mm, acquisition time 22-26 sec. Individual circulation times were determined by a test bolus before each MR angiography. Conventional arteri…
Total occlusion of aortic arch in a 62-year-old man presenting with acute myocardial infarction
2011
Not available
Assessment of Thoracic Aortic Dimensions in an Experimental Setting: Comparison of Different Unenhanced Magnetic Resonance Angiography Techniques Wit…
2008
PURPOSE To compare different unenhanced magnetic resonance angiography (MRA) techniques for quantitative evaluation of vessel lumen in an experimental setting in young pigs whose dimensions allow for a comparison with a pediatric population. MATERIAL AND METHODS Magnetic resonance imaging was performed in 5 healthy ventilated pigs at 1.5 T. Three different electrocardiogram (ECG)-triggered sequences were applied for MRA: [TSE-Db] T2-weighted dark-blood TurboSpinEcho (2.0 x 1.1 x 4 mm3); [trueFISP] 2D-steady-state-free-precession (2.2 x 1.8 x 2 mm3); [NAV] respiratory-gated, T2-prepared 3D-trueFISP (1.3 x 1.3 x 1.3 mm3). ECG-gated-CT angiography (CTA) (16-row CT, 1 mm collimation) served as …
In Silico Shear and Intramural Stresses are Linked to Aortic Valve Morphology in Dilated Ascending Aorta
2017
Objective/Background: The development of ascending aortic dilatation in patients with bicuspid aortic valve (BAV) is highly variable, and this makes surgical decision strategies particularly challenging. The purpose of this study was to identify new predictors, other than the well established aortic size, that may help to stratify the risk of aortic dilatation in BAV patients.Methods: Using fluid-structure interaction analysis, both haemodynamic and structural parameters exerted on the ascending aortic wall of patients with either BAV ( n = 21) or tricuspid aortic valve (TAV; n = 13) with comparable age and aortic diameter (42.7 +/- 5.3 mm for BAV and 45.4 +/- 10.0 mm for TAV) were compared…
Echocardiographic and angiographic evaluation of left ventricular function during percutaneous transluminal aortic valvuloplasty.
1992
Transesophageal echocardiography was used to study the effect of the balloon inflation on left ventricular function in 20 patients with critical aortic stenosis undergoing balloon valvuloplasty. Balloon inflation caused an increase of end-diastolic (15% to 34%) and end-systolic (57% to 72%) left ventricular volume. Left ventricular wall stress increased from 30 +/- 10 x 10(3) dyn/cm2 at diastole and 121 +/- 40 x 10(3) dyn/cm2 at systole to 44 +/- 11 x 10(3) dyn/cm2 and 191 +/- 55 x 10(3) dyn/cm2, respectively, when the balloon was inflated (P less than 0.05). Turbulent regurgitant jet across the mitral valve increased from 15 +/- 2% to 25 +/- 3% during balloon inflation (P less than 0.01). …
TAVI imaging: over the echocardiography
2020
Aortic valve stenosis (AS) is a common valvular heart disease. Recently, transcatheter aortic valve implantation (TAVI) has changed the treatment of severe AS in elderly patients with contraindications to traditional surgical replacement. Echocardiography is conventionally used as the first imaging modality to assess the presence and severity of AS and to provide anatomical and functional information. Nowadays, imaging techniques play a crucial role in the planning of TAVI to define suitable candidates. Computed tomography (CT) is essential to display the anatomy of the aortic valve complex (including aortic annulus, Valsalva sinuses, coronary arteries ostia, sinotubular junction), thoracoa…