Search results for " Angiography"
showing 10 items of 609 documents
Transcatheter radiofrequency perforation and stent implantation for palliation of pulmonary atresia in a 3060-g infant
1995
In a 3060-g infant with fibromuscular pulmonary atresia an open right ventricular outflow tract was created by means of interventional cardiological methods. Following two inadvertent perforations without sequelae or clinical symptoms, radiofrequency perforation and subsequent balloon dilatation were successfully performed. The implantation of a Palmaz iliac stent led to a predictable communication between the right ventricle and pulmonary artery.
High Degree of Realism in Teaching Percutaneous Coronary Interventions by Combining a Virtual Reality Trainer With a Full Scale Patient Simulator
2008
The virtual reality coronary angiography simulator "CATHI" (Catheter Instruction System, Mannheim, Germany) simulates coronary arteries with implemented vessel lesions in virtual patients. Like similar systems the software model runs on common PC systems, which are linked to the mechanical device for manual training. We combined the advantages of this skill trainer with the near to reality assembly of a cardiac catheterization laboratory (Cath-lab) by connecting it to a full scale simulator (HPS, METI, Sarasota, FL). We present two methods of synchronizing the heartbeat between both simulation devices. Method A-the hardware solution-uses the electrocardiogram-synchronization signal of the H…
Computer-aided detection of cerebral microbleeds in susceptibility-weighted imaging.
2014
Susceptibility-weighted imaging (SWI) is recognized as the preferred MRI technique for visualizing cerebral vasculature and related pathologies such as cerebral microbleeds (CMBs). Manual identification of CMBs is time-consuming, has limited reliability and reproducibility, and is prone to misinterpretation. In this paper, a novel computer-aided microbleed detection technique based on machine learning is presented: First, spherical-like objects (potential CMB candidates) with their corresponding bounding boxes were detected using a novel multi-scale Laplacian of Gaussian technique. A set of robust 3-dimensional Radon- and Hessian-based shape descriptors within each bounding box were then ex…
Aspiration thrombectomy for patients with acute coronary syndromes and culprit lesions located in coronary bypass grafts. Data from the PL-ACS regist…
2022
Admission glycemia and in-hospital death following cardiac arrest during myocardial infarction outside hospital
2013
A new concept to treat lumbar spine stenosis in a mini invasive way
2017
Avoiding Complications in Aneurysm Ligation: Operative Tips and Tricks
2022
Preventing possible complications during brain aneurysm surgery is mandatory to ensure a better outcome for patients. Currently, it is possible to rely on some technologic innovations such as motor evoked potential, endoscope-assisted surgery, dye with indocyanine green, and video angiography capable of supporting the surgeon's work. The innovation process has mainly assisted the endovascular technique compared with surgery. The latter, apart from some new technical expedients, always requires anatomic knowledge and optimal technical preparation. A careful patient selection, adequate surgical exposure, use of microsurgical techniques in expert hands, and meticulous postoperative management …
Indocyanine Green Angiography in Congenital Hypertrophy of the Retinal Pigment Epithelium
2017
PURPOSE To report a case of congenital hypertrophy of the retinal pigment epithelium followed up for 7 years showing features not previously reported. METHODS A complete fundus examination including fluorescein angiography was performed at first examination and at follow-up. RESULTS The area of congenital hypertrophy of the retinal pigment epithelium presented morphologic changes, showing enlargement of the lesion on one side associated with partial regression on another side. In addition, the indocyanine green angiography findings revealed that this test was more useful than fluorescein angiography to delineate the real boundaries of the lesion and disclosed hypofluorescent areas inside th…
Image guidance to improve reliability and data integrity of transcranial Doppler sonography.
2012
Abstract Background Principles and accuracy of image-guided transcranial Doppler (IG TCD) sonography have been published recently. However, it remains open whether combination of image guidance and TCD offers an additional clinical advantage. This study scores the accuracy of conventional TCD examinations and investigates the potential improvement of TCD data integrity and reliability regarding the additional use of IG. Methods Conventional TCD was performed by a group of experienced investigators, who were blinded to images of a navigation system tracking the Doppler probe, whereas an independent observer documented the TCD findings, acquired by the investigators, due to saving spatial dat…
[Ischemia with no obstructive coronary artery disease: microvascular angina and vasospastic angina].
2020
About 40% of patients undergoing coronary angiography for chest pain with anginal features have angiographically normal or near-normal coronary arteries. It was necessary to standardize all myocardial ischemia scenarios in stable patients in the absence of coronary artery disease, therefore the term INOCA (ischemia with non-obstructive coronary artery disease) was coined. The aim of this article is to summarize and to clarify the vast and controversial chapter of INOCA, in order to better understand the pathophysiological, nosographic, diagnostic and therapeutic aspects.