Search results for " Aorta"
showing 10 items of 185 documents
Early LVAD Implantation in a Patient with Left Ventricular Failure after Aortic Dissection with Left Main Stem Involvement
2018
Background: Coronary involvement in aortic dissection heralds a poor outcome. Involvement of the left main stem may lead to left ventricular (LV) failure requiring mechanical circulatory support. Case Report: A staged approach was applied in a 24-year-old female who suffered extensive infarction due to aortic dissection with left main stem involvement. After replacement of the ascending aorta and grafting of the left internal thoracic artery to the left anterior descending artery following a failed attempt at reconstruction of the left coronary ostium, she failed to wean from cardiopulmonary bypass (CPB) and underwent implantation of an extracorporeal life support (ECLS) system as a bridge …
Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?
2011
Thoracic endovascular aortic repair (TEVAR) has emerged as a promising therapeutic alternative to conventional open aortic replacement but it requires suitable proximal and distal landing zones for stent-graft anchoring. Many aortic pathologies affect in the immediate proximity of the left subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre has the potential for immediate and delayed neurological and vascular symptoms. Some authors, ther…
Abdominal aortic aneurysm wall rupture risk evaluation through computerized element analysis model and fuzzy-tosis decision method.
2008
Gli aneurismi dell'aorta addominale
2009
Not available
Aneurisma dell'aorta addominale e patologia neoplastica associata
2012
Abdominal Aortic Aneurysm
2009
Chimney endografting for pararenal aortic pathologies using transfemoral access and the lift technique
2013
Purpose: To present a technique for transfemoral implantation of parallel grafts into the renal arteries in patients with anatomy or morphology that blocks standard antegrade chimney graft delivery. Technique: In a totally percutaneous approach, a 5-F pigtail angiographic catheter is passed into the aorta above the renal arteries via a 0.035-inch hydrophilic guidewire, followed by an 8-F sheath. The target vessel is cannulated with the hydrophilic wire followed by a 5-F reverse curve catheter; the wire is changed for a Rosen wire. The main stent-graft body is delivered and parked at the level of the aortic bifurcation. The Viabahn chimney endograft is advanced ~1 to 2 cm into the target ren…
Ruolo della Cardio TC in pazienti con aneurisma dell’aorta ascendente.
2016
The aim of our study is to evaluate the diagnostic accuracy of cardio CT (CTC) in patients with ascending aortic aneurysm displayed at Transthoracic Echocardiography (ETT).
64-MDCT ECG gating in the evaluation of pre and post-operative ascending aorta: what is essential to know and necessary to report?
2007
CT-Angiographie versus intraarterielle DSA bei Bauchaortenaneurysmen
1996
PURPOSE To evaluate if CT angiography is able to image all features necessary for the preoperative planning of abdominal aortic aneurysms (accessory renal arteries, stenoses or occlusions of renal and iliac arteries, patency of inferior mesenteric artery). METHODS CT angiography and DSA were performed on 27 patients with abdominal aortic aneurysms. CT angiography was performed using a protocol that covered the abdominal aorta and the pelvic arteries with a single spiral acquisition (contrast dose: 150 ml, collimation: 5 mm, table feed: 7.5 mm/s, increment of reconstruction: 2 mm). Maximum intensity projections (MIP) and axial scans were compared with the results of intraarterial DSA. RESULT…