Search results for " Auditory"

showing 10 items of 240 documents

The internal auditory artery: (embryology, anatomy, angiography, pathology).

1975

A review of the literature on the embryology, anatomy and angiography of the internal auditory artery has shown that there may be considerable variation as to the origin and number of internal auditory arteries. The present study, based on serial magnification angiographies of the internal auditory artery, has demonstrated 7 variants of the origin of this artery although in 45.4% of cases the internal auditory artery arose from the anterior inferior cerebellar artery. For the diagnosis of pathological processes in the cerebellopontine angle (tumors, sudden deafness, vascular abnormalities) magnification angiography is of special importance. Acoustic neurinomas in particular can be diagnosed…

AdultPathologymedicine.medical_specialtyNeurologyeducationMagnificationCerebellopontine AngleDeafnessInternal Auditory Arterymedicine.arteryCerebellummedicineHumansCerebellar NeoplasmsNeuroradiologymedicine.diagnostic_testbusiness.industryAngiographyIntracranial AneurysmAnatomyArteriesMiddle AgedCerebellopontine angleAnterior inferior cerebellar arterymedicine.anatomical_structureNeurologyBasilar ArteryEar InnerAngiographyFemaleNeurology (clinical)RadiologybusinessArteryJournal of neurology
researchProduct

Dipole Source Analysis of Laser-Evoked Subdural Potentials Recorded From Parasylvian Cortex in Humans

2003

The location of the human nociceptive area(s) near the Sylvian fissure is still controversial in spite of evidence from imaging and evoked potential studies that noxious heat stimuli activate somatosensory areas in that region. Some studies have suggested the secondary somatosensory cortex (SII) on the upper bank of the Sylvian fissure posterior to the central sulcus, others the anterior insula or parietal area 7b. In this study, we applied dipole source analysis techniques to laser-evoked potentials (LEPs) that were recorded from subdural grid electrodes in three patients. As a functional marker, auditory-evoked potentials (AEPs) with a generator on the opposite bank of the Sylvian fissur…

AdultPhysiologyPainSubdural SpaceSomatosensory systemParietal LobeCortex (anatomy)medicineHumansEvoked potentialOperculum (brain)ElectrodesEvoked PotentialsPhysicsSecondary somatosensory cortexLasersGeneral NeuroscienceParietal lobeSomatosensory CortexAnatomyMagnetic Resonance ImagingCentral sulcusFrontal LobeElectrophysiologymedicine.anatomical_structureEpilepsy Temporal LobeFrontal lobeEvoked Potentials AuditoryNeuroscienceJournal of Neurophysiology
researchProduct

Early auditory evoked potentials: developmental aspects and validity in neuropaediatric and audiologic disorders.

1984

Auditory evoked potentials and in this context especially five waves in the first 10 ms (early auditory evoked potentials = EAEP) are a diagnostic aid in topodiagnosis of posterior fossa diseases. This is due to waves I to V which arise along the acoustic nerve and in brain stem structures such as medulla, pons and mid-brain. Besides an indication about the site of a lesion in the posterior fossa, wave V allows an objective threshold determination. The present results were gained in normal children aged 1-3 years and in children with neuropaediatric and audiologic disorders.

Adultmedicine.medical_specialtyAgingAdolescentPosterior fossaNeural ConductionContext (language use)AudiologyDiagnostic aidLesionChild DevelopmentMedicineHumansChildHearing DisordersMedullaNeural Conductionbusiness.industryBrain NeoplasmsInfant NewbornInfantDiffuse Cerebral Sclerosis of SchilderLeukodystrophy MetachromaticPonsChild PreschoolPediatrics Perinatology and Child HealthNormal childrenEvoked Potentials Auditorymedicine.symptomNervous System DiseasesbusinessBrain StemEuropean journal of pediatrics
researchProduct

Effects of contralateral white noise stimulation on transitory evoked otoacoustic emissions in patients with acoustic neuroma.

1995

Abstract Transitory evoked otoacoustic emissions are normal phenomena observed in most persons with hearing levels greater than 35 dB. Further, masking of the contralateral ear produces amplitude reductions in the transitory evoked otoacoustic emissions. We have undertaken a study of transitory evoked otoacoustic emissions in 20 patients with acoustic neuroma. All patients were assessed for transitory evoked otoacoustic emissions bilaterally, with and without contralateral masking with white band noise at 40, 50, and 60 dB. We found that transitory evoked otoacoustic emissions were present in 30% of ears with tumor and that the presence of transitory evoked otoacoustic emissions is associat…

Adultmedicine.medical_specialtyHearing Loss SensorineuralAcoustic neuromaStimulationAmplitude reductionAudiologyVestibular NerveNeurons EfferentHearingotorhinolaryngologic diseasesMedicineHumansIn patientProspective StudiesAgedTumor sizebusiness.industryHead neckAuditory ThresholdNeuroma AcousticMiddle Agedmedicine.diseaseCochleaHair Cells Auditory OuterWhite bandOtorhinolaryngologyAcoustic StimulationEvoked Potentials AuditoryContralateral earSurgerysense organsbusinessNoisePetrous BoneOtolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery
researchProduct

Mismatch negativity during objective and subjective sleepiness.

1997

The mismatch negativity (MMN) and P3 of auditory event-related potentials were studied during subjectively and objectively (physiologically) defined sleepiness under optimal stimulus conditions for MMN elicitation. The MMN and P3 were elicited by either small or large unattended auditory deviants presented to the left ear. The participant's task was to detect either rare auditory targets presented to the right ear or rare changes in the light flashes. Eleven young adults served as participants in a nighttime experiment. The MMN declined especially at Fz and Cz but not so markedly at the right mastoid as either subjective or objective alertness decreased. The amplitude of P3 also decreased d…

Adultmedicine.medical_specialtySleep stateCognitive Neurosciencemedia_common.quotation_subjectMismatch negativityExperimental and Cognitive PsychologyStimulus (physiology)Audiologybehavioral disciplines and activitiesDevelopmental psychologyDevelopmental NeuroscienceEvent-related potentialmedicineReaction TimeHumansAttentionBiological Psychiatrymedia_commonEndocrine and Autonomic SystemsElectromyographyGeneral NeuroscienceElectroencephalographyElectrophysiologyAlertnessElectrooculographyNeuropsychology and Physiological PsychologyNeurologyAcoustic StimulationEvoked Potentials Auditorymedicine.symptomPsychologySleeppsychological phenomena and processesSomnolenceVigilance (psychology)Psychophysiology
researchProduct

Brain reacts to occasional changes in duration of elements in a continuous sound

1995

In order to study the event-related potential correlates of human ability to detect temporal changes within a continuous sound a sound consisting of two alternating pitches of the same constant duration, with infrequent shortenings of one of the tones, was presented to the subjects. The infrequent shortenings were found to elicit a negative component of the auditory event related potential, called the mismatch negativity (MMN). The experimental parameters were chosen to produce a MMN with a minimal contamination of N1, the main negative deflection of an evoked response with the same latency range as MMN and with a short experimental time. The duration of the whole experiment with three diff…

Adultmedicine.medical_specialtyTime FactorsAuditory eventGeneral NeuroscienceBrainMismatch negativityElectroencephalographyAudiologybehavioral disciplines and activitiesElectrophysiologyDiscrimination PsychologicalSoundAcoustic StimulationEvoked Potentials AuditorymedicineHumansPsychologyNeuroReport
researchProduct

Cortical responses of infants with and without a genetic risk for dyslexia

1999

We studied auditory event-related potentials (ERP) in newborns and 6-month-old infants, about half of whom had a familial risk for dyslexia. Syllables varying in vowel duration were presented in an oddball paradigm, in which ERPs to deviating stimuli are assumed to reflect automatic change detection in the brain. The ERPs of newborns had slow positive deflections typical of their age, but significant stimulus and group effects were found only by the age of 6 months. In both groups, the responses to the deviant /ka/ were more positive than those to the standard /kaa/ stimuli, contrary to the findings of adult ERPs to duration changes. The results also suggested differences in brain activatio…

Agingmedicine.medical_specialtygenetic structuresmedia_common.quotation_subjectStimulus (physiology)Audiologybehavioral disciplines and activitiesDevelopmental psychologyDyslexiaGroup differencesPhoneticsReference ValuesRisk FactorsPerceptionmedicineHumansLanguage disorderGenetic riskmedia_commonCerebral CortexGeneral NeuroscienceInfant NewbornDyslexiaInfantPhoneticsmedicine.diseaseIncreased riskAcoustic StimulationEvoked Potentials AuditoryPsychologypsychological phenomena and processesNeuroReport
researchProduct

Progress in electron microscopic diagnostics: semi-quantitative determination of precipitable calcium in different cell types of the organ of Corti i…

1991

Potassium antimonate was used to precipitate calcium in the cochlea of the guinea-pig. The distribution of the calcium antimonate precipitates was analysed by electron microscopy. The precipitate density was determined in different cell types in the organ of Corti by counting the number of calcium binding sites in a 10-micron 2 area. The size of the precipitates varied considerably, and thus the relative amount of the precipitable calcium was estimated only semi-quantitatively. As the prominent carbon signal is superimposed over the nearby small Ca(2+)-edge signals, the combined signal of the antimony M4,5-edge and the oxygen K-edge of the calcium antimonate salt formed was chosen for the s…

AntimonyCytoplasmHistologyGuinea PigsAnalytical chemistrychemistry.chemical_elementCalciumPathology and Forensic Medicinelaw.inventionAntimonylawHair Cells AuditoryMicroscopyImage Processing Computer-AssistedmedicineAnimalsChemical PrecipitationOrgan of CortiCochleaOrganellesPrecipitation (chemistry)Spectrum AnalysisMitochondriaMicroscopy Electronmedicine.anatomical_structurechemistryOrgan of CortiCytoplasmCalciumElectron microscopeJournal of Microscopy
researchProduct

Auditory cortical event-related potentials to pitch deviances in rats

1998

Abstract We recorded epidural event-related potentials (ERPs) from the auditory cortex in anesthetized rats when pitch-deviant tones were presented in a homogenous series of standard tones (oddball condition). Additionally, deviant tones were presented without standard tones (deviant-alone condition). ERPs to deviant tones in the oddball condition differed significantly from ERPs to standard tones at the latency range of 63–243 ms. On the other hand, ERPs to deviant tones in the deviant-alone condition did not differ from ERPs to standard tones until 196 ms from stimulus onset. The results suggest that oddball stimuli can be neurophysiologically discriminated in anesthetized rats. Furthermo…

Auditory Cortexmedicine.medical_specialtygenetic structuresGeneral NeuroscienceeducationMismatch negativityStimulus (physiology)AudiologyAuditory cortexbehavioral disciplines and activitiesRatsPitch DiscriminationElectrophysiologyEvent-related potentialmental disordersEvoked Potentials AuditorymedicineAnimalsRats WistarPsychologypsychological phenomena and processesNeuroscience Letters
researchProduct

Auditory distance perception in an acoustic pipe

2008

In a study of auditory distance perception, we investigated the effects of exaggeration the acoustic cue of reverberation where the intensity of sound did not vary noticeably. The set of stimuli was obtained by moving a sound source inside a 10.2-m long pipe having a 0.3-m diameter. Twelve subjects were asked to listen to a speech sound while keeping their head inside the pipe and then to estimate the egocentric distance from the sound source using a magnitude production procedure. The procedure was repeated eighteen times using six different positions of the sound source. Results show that the point at which perceived distance equals physical distance is located approximately 3.5 m away fr…

Auditory displayReverberationRange (music)Critical distanceSound and Music ComputingGeneral Computer SciencePerformanceSpeech recognitionmedia_common.quotation_subjectExperimental and Cognitive PsychologySound and Music Computing; Auditory display; Distance perceptionTheoretical Computer ScienceLoudnessPerceptionExperimentationSound (geography)media_commonMathematicsExperimentation; Measurement; Performance; Acoustic pipe; Auditory display; Distance perceptionMeasurementgeographygeography.geographical_feature_categorySettore INF/01 - InformaticaAuditory displaySound intensityAcoustic pipeAcoustic pipe; auditory display; distance perceptionDistance perceptionACM Transactions on Applied Perception
researchProduct