A fully automated method for accurate measurement of geometrical distortion in magnetic resonance imaging of a 3D-lattice phantom
2019
Abstract This paper describes an automated method for extracting the apparent positions of fiducial points from 2D or 3D images of a phantom. We consider a 3D-lattice phantom for two main reasons: first, ease of manufacture and isotropy of its structure with respect to coordinate projections; second, a connected structure allowing to uniquely assess the adjacency relationship between fiducial points even if geometric distortions arising from main magnet inhomogeneity and gradient fields non-linearity is severe as observed in open-bore systems. In order to validate our proposed method and compare different choices for the parameters of our phantom (i.e. number and distance between grids and …
Clinical Applications, Pitfalls, and Uncertainties of Thrombin Generation in the Presence of Platelets
2019
Platelet-dependent thrombin generation is a helpful tool to assess ex vivo the interaction between platelets and plasma coagulation factors in the initiation, amplification, and inhibition of thrombin generation (TG). This review article discusses the most relevant available data on the clinical applications of fluorogenic TG, the most widely used TG assay, performed in the presence of platelets, i.e., in platelet-rich plasma. With respect to prothrombotic states, arterial hypertension and obesity were the most prominent cardiovascular conditions linked to increased platelet-dependent TG. In addition, platelet-associated hypercoagulability, assessed by the TG assay, has been shown in indivi…
The automated pancreas: A review of technologies and clinical practice
2021
Insulin pumps and glucose sensors are effective in improving diabetes therapy and reducing acute complications. The combination of both devices using an algorithm-driven interoperable controller makes automated insulin delivery (AID) systems possible. Many AID systems have been tested in clinical trials and have proven safety and effectiveness. However, currently, none of these systems are available for routine use in children younger than 6 years in Europe. For continued use, both users and prescribers must have sound knowledge of the features of the individual AID systems. Presently, all systems require various user interactions (e.g. meal announcements) because fully automated systems ar…
Quantification of vesicles in differentiating human SH-SY5Y neuroblastoma cells by automated image analysis
2005
A new automated image analysis method for quantification of fluorescent dots is presented. This method facilitates counting the number of fluorescent puncta in specific locations of individual cells and also enables estimation of the number of cells by detecting the labeled nuclei. The method is here used for counting the AM1-43 labeled fluorescent puncta in human SH-SY5Y neuroblastoma cells induced to differentiate with all-trans retinoic acid (RA), and further stimulated with high potassium (K+) containing solution. The automated quantification results correlate well with the results obtained manually through visual inspection. The manual method has the disadvantage of being slow, labor-i…
Remote estimation of blood pulse pressure via temporal tracking of reflected secondary speckles pattern
2011
We present a novel technique for remote noncontact blood pulse pressure measurement. It is based on tracking both temporal and amplitude changes of reflected secondary speckle produced in human skin when illuminated by a laser beam. The implemented technique extracts the difference between the systolic and the diastolic blood pressure. Experimental results are presented showing good agreement when compared with conventional measurement methods.
Automated classification of focal breast lesions according to S-detect: validation and role as a clinical and teaching tool
2018
Abstract PURPOSE: To assess the diagnostic performance and the potential as a teaching tool of S-detect in the assessment of focal breast lesions. METHODS: 61 patients (age 21-84 years) with benign breast lesions in follow-up or candidate to pathological sampling or with suspicious lesions candidate to biopsy were enrolled. The study was based on a prospective and on a retrospective phase. In the prospective phase, after completion of baseline US by an experienced breast radiologist and S-detect assessment, 5 operators with different experience and dedication to breast radiology performed elastographic exams. In the retrospective phase, the 5 operators performed a retrospective assessment a…
Unsupervised recognition of retinal vascular junction points.
2014
Landmark points in retinal images can be used to create a graph representation to understand and to diagnose not only different pathologies of the eye, but also a variety of more general diseases. Aim of this paper is the description of a non-supervised methodology to distinguish between bifurcations and crossings of the retinal vessels, which can be used in differentiating between arteries and veins. A thinned representation of the binarized image, is used to identify pixels with three or more neighbors. Junction points are classified into bifurcations or crossovers according to their geometrical and topological properties. The proposed approach is successfully compared with the state-of-t…
Superresolved imaging of remote moving targets.
2006
We present a superresolving approach that allows one to exceed the diffraction limit and recover highly resolved contours of moving targets from a sequence of low-resolution images. The presented approach is suitable for remote sensing applications. The resolution decoding algorithm that is used to recover the high-resolution features of the target can be run partially via optical means and that way can be used to reduce the required computational complexity.
Porti e automazione: spunti in materia di responsabilità delle imprese di sbarco
2019
Lo studio si incentra sull'automazione delle operazioni portuali di imbarco e di sbarco, con particolare riferimento all'incidenza della tecnologia sul sistema di responsabilità degli attori del trasporto marittimo. Sarà trattata la normativa portuale, la governance, il sistema di protezione sociale dei lavoratori portuali e il regime giuridico dei terminal operator. La relazione tra attività totalmente automatizzata e infrastrutture marittime è analizzata nel contesto del diritto internazionale marittimo. The article focuses on the automatization of loading, stowing and unloading ports operations, from the point of view of the impact of the technologies on the system of liabilities of the …
A computer system to perform structure comparison using TOPS representations of protein structure
2001
We describe the design and implementation of a fast topology-based method for protein structure comparison. The approach uses the TOPS topological representation of protein structure, aligning two structures using a common discovered pattern and generating measure of distance derived from an insert score. Heavy use is made of a constraint-based pattern-matching algorithm for TOPS diagrams that we have designed and described elsewhere (Bioinformatics 15(4) (1999) 317). The comparison system is maintained at the European Bioinformatics Institute and is available over the Web at tops.ebi.ac.uk/tops. Users submit a structure description in Protein Data Bank (PDB) format and can compare it with …