Search results for " BRACHYTHERAPY"
showing 10 items of 44 documents
A simple analytical method for heterogeneity corrections in low dose rate prostate brachytherapy
2015
In low energy brachytherapy, the presence of tissue heterogeneities contributes significantly to the discrepancies observed between treatment plan and delivered dose. In this work, we present a simplified analytical dose calculation algorithm for heterogeneous tissue. We compare it with Monte Carlo computations and assess its suitability for integration in clinical treatment planning systems. The algorithm, named as RayStretch, is based on the classic equivalent path length method and TG-43 reference data. Analytical and Monte Carlo dose calculations using Penelope2008 are compared for a benchmark case: a prostate patient with calcifications. The results show a remarkable agreement between …
Intravitreal aflibercept for the treatment of radiation-induced macular edema after ruthenium 106 plaque radiotherapy for choroidal melanoma.
2019
Purpose: To assess the efficacy of intravitreal aflibercept in patients suffering from post-radiation macular edema following plaque radiotherapy for choroidal melanoma. Methods: This prospective, interventional case series included patients affected by radiation maculopathy (RM) with macular edema secondary to ruthenium-106 plaque brachytherapy for choroidal melanoma. The effect of intravitreal aflibercept on best-corrected visual acuity (BCVA), central foveal thickness (CFT) detected by spectral domain optical coherence tomography (sd-OCT), and Horgan’s grading scale of RM was evaluated throughout the 24-month follow-up. Intraocular pressure (IOP) and possible complications were also reco…
High-dose-rate brachytherapy boost for prostate cancer: Analysis of dose-volume histogram parameters for predicting late, rectal toxicity
2017
PURPOSE: To determine the significance of dose-volume histogram parameters for predicting late rectal toxicity (LRT) after single-fraction high-dose-rate brachytherapy (HDRBT) boost and external beam radiotherapy (EBRT) in prostate cancer. MATERIALS AND METHODS: Three hundred patients with intermediate- or high-risk prostate cancer were included between August 2010 and March 2015. Treatment comprised a single-fraction HDRBT boost of 15.0 Gy plus EBRT (46.0 Gy delivered in 23 fractions) or an HDRBT boost of 9.5 Gy plus EBRT (60.0 Gy delivered in 30 fractions) if the seminal vesicles were infiltrated using real-time transrectal ultrasound-based planning. LRT was evaluated every 3 months after…
Focal or whole-gland salvage prostate brachytherapy with iodine seeds with or without a rectal spacer for postradiotherapy local failure: How best to…
2016
International audience; PURPOSE: Salvage prostate permanent implant (sPPI) for postradiation local failure provides high rates of biochemical control. The cumulative dose delivered to the prostate and the rectum is still unknown. METHODS AND MATERIALS: We reviewed the postimplant CT-based dosimetry of 18 selected patients who underwent sPPI with I-125 seeds for isolated biopsy-proven local failure several years after external beam radiation therapy. Ten patients had whole-prostate sPPI, and 8 patients had multiparametric MRI-based focal sPPI. In 8 patients, hyaluronic acid (HA) gel was injected into the prostate rectum space. RESULTS: The median cumulative biological effective dose after EB…
Interobserver variability in rectum contouring in high-dose-rate brachytherapy for prostate cancer: A multi-institutional prospective analysis
2017
PURPOSE: The aim of this study was to evaluate the interobserver variability (KW) of rectum contouring, and its dosimetric consequences, for high-dose-rate brachytherapy in patients with prostate cancer across multiple institutions. METHODS AND MATERIALS: Five radiation oncologists contoured rectums in 10 patients on transperineal ultrasound image sets after establishing a delineation consensus. The D-0.1cc, D-1cc, and D-2cc rectum volume parameters were determined. The mean, standard deviation, and range of each dose-volume histogram parameter were evaluated for each patient. The JOY was determined using the coefficient of variation, and the dosimetric impacts on the total dose were analyz…
Intramural neovascularization and haemorrhages are major long‐term effects of intravascularγ‐radiation after stenting
2003
Structural changes that might influence the structural integrity of the vessel in response to intravascular brachytherapy (IVB) and stenting were examined, focus being on the importance of neovascularization in rabbit stented arteries. Stents were implanted in the infrarenal aortas of rabbits, immediately followed by gamma IVB or a sham radiation procedure, and the arteries harvested at 6 months. Labelling for von Willebrand factor showed an increase in adventitial and medial neovascularization in irradiated versus control arteries group (5.04+/-0.89 versus 1.51+/-0.23 mm(-2), respectively; p=0.004). Moreover, intramedial haemorrhages (free hemosiderin deposition) and inflammation (macropha…
Is high dose rate brachytherapy reliable and effective treatment for prostate cancer patients? A review of the literature.
2014
The intrinsic physical and radiobiological characteristics of High Dose Rate Brachytherapy (HDR-BT) are well suited to the treatment of prostate cancer. HDR-BT was initially used as a boost to external beam brachytherapy, but has subsequently been employed as the sole treatment, which is termed HDR monotherapy. This review summarizes the clinical outcomes and toxicity results of the principal studies and discusses the radiobiological basis supporting its use.
Multiparametric MRI and post implant CT-based dosimetry after prostate brachytherapy with iodine seeds: The higher the dose to the dominant index les…
2015
Abstract Purpose To determine whether post-implant MRI-based dosimetry of the Dominant Intra-prostatic Lesion (DIL) could best predict the occurrence of PSA bounce after prostate brachytherapy. Methods and materials We selected 66 patients with a low risk prostate cancer treated with 125 I prostate brachytherapy as monotherapy. Post-implant dosimetry based on day 30 CT-scan and multiparametric MRI co-registration was generated: planned D 90, D 95, V 100, V 150 values were calculated for each DIL. Bounce was defined as a PSA elevation ⩾0.2ng/mL from the previous baseline value followed by a decrease to or below the prior nadir with no additional treatment. Results After a median follow-up of…
Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations
2014
Purpose: In skin high-dose-rate (HDR) brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Most treatment planning systems use the TG-43 formalism, which is based on single-source dose superposition within an infinite water medium without accounting for the true geometry in which conditions for scattered radiation are altered by the presence of air. The purpose of this study is to evaluate the dosimetric limitations of the TG-43 formalism in HDR skin brachytherapy and the potential clinical impact. Methods: Dose rate distributions of typical configurations used in skin brachytherapy were obtained: a 5 cm × 5 cm superficial mould; a …
A monte carlo study of dose rate distribution around the specially asymmetric CSM3-a 137Cs source.
2001
The CSM3 137Cs type stainless-steel encapsulated source is widely used in manually afterloaded low dose rate brachytherapy. A specially asymmetric source, CSM3-a, has been designed by CIS Bio International (France) substituting the eyelet side seed with an inactive material in the CSM3 source. This modification has been done in order to allow a uniform dose level over the upper vaginal surface when this `linear' source is inserted at the top of the dome vaginal applicators. In this study the Monte Carlo GEANT3 simulation code, incorporating the source geometry in detail, was used to investigate the dosimetric characteristics of this special CSM3-a 137Cs brachytherapy source. The absolute do…